{"title":"Efficacy and safety of the implantation of a single-piece angulated foldable IOL in the sulcus","authors":"Gauthier Blanckaert, Joachim Van Calster, Joyce Jansen, Joris Vander Mijnsbrugge, Ann-Laure Delbecq, Ivo De Clerck, Jean-François Fils, Peter Stalmans","doi":"10.1007/s00417-024-06459-0","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Purpose</h3><p>To study the visual results and tolerance of a Zeiss CT Lucia 601P intraocular lens (IOL) implanted in the sulcus after complicated cataract surgery or during IOL exchange for clouded IOL.</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>In total, 64 patients who underwent sulcus implantation were recalled to the hospital to undergo subjective and objective refraction, best corrected visual acuity measurement, tonometry, optical coherence tomography, laser flare photometry, biometry, and wavefront aberrometry.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>In spite of a large variation in preoperative refraction, the target refraction was obtained within 1.5 diopters in approximately 97% of patients and within 0.5 diopter in 53% of patients. Average BCVA was high (Snellen 0.86) and related to concomitant (mostly retinal) pathologies in eyes with poorer visual performance. Wavefront aberrometry showed no evidence of IOL tilting or decentration after long-term implantation in the sulcus. Tonometry was not different from the fellow eye of the patient (<i>p</i> &gt; 0.5). In 53 patients with bilateral pseudophakia, the laser flare photometry was not significantly different from the fellow eye (<i>p</i> &lt; 0.05).</p><h3 data-test=\"abstract-sub-heading\">Conclusion</h3><p>This study demonstrates that this single-piece angulated foldable acrylic IOL can be considered for implantation in the sulcus. The visual results are favorable, and the IOL can be well-positioned and tolerated in the sulcus. Moreover, there were no safety issues found since there was no evidence of elevated IOP or chronic uveitis.</p>","PeriodicalId":12748,"journal":{"name":"Graefe's Archive for Clinical and Experimental Ophthalmology","volume":"2016 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe's Archive for Clinical and Experimental Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00417-024-06459-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To study the visual results and tolerance of a Zeiss CT Lucia 601P intraocular lens (IOL) implanted in the sulcus after complicated cataract surgery or during IOL exchange for clouded IOL.

Methods

In total, 64 patients who underwent sulcus implantation were recalled to the hospital to undergo subjective and objective refraction, best corrected visual acuity measurement, tonometry, optical coherence tomography, laser flare photometry, biometry, and wavefront aberrometry.

Results

In spite of a large variation in preoperative refraction, the target refraction was obtained within 1.5 diopters in approximately 97% of patients and within 0.5 diopter in 53% of patients. Average BCVA was high (Snellen 0.86) and related to concomitant (mostly retinal) pathologies in eyes with poorer visual performance. Wavefront aberrometry showed no evidence of IOL tilting or decentration after long-term implantation in the sulcus. Tonometry was not different from the fellow eye of the patient (p > 0.5). In 53 patients with bilateral pseudophakia, the laser flare photometry was not significantly different from the fellow eye (p < 0.05).

Conclusion

This study demonstrates that this single-piece angulated foldable acrylic IOL can be considered for implantation in the sulcus. The visual results are favorable, and the IOL can be well-positioned and tolerated in the sulcus. Moreover, there were no safety issues found since there was no evidence of elevated IOP or chronic uveitis.

Abstract Image

在沟内植入单片角折叠式人工晶体的有效性和安全性
目的 研究复杂白内障手术后或因人工晶体混浊而进行人工晶体置换时,在沟内植入蔡司 CT Lucia 601P 人工晶体(IOL)的视觉效果和耐受性。结果尽管术前屈光度数差异很大,但约 97% 的患者目标屈光度在 1.5 屈光度以内,53% 的患者目标屈光度在 0.5 屈光度以内。BCVA 平均值较高(斯奈伦 0.86),视力较差的眼睛与伴随的病变(主要是视网膜病变)有关。波前像差测量法显示,在沟内长期植入人工晶体后,没有证据表明人工晶体倾斜或下垂。眼压测量与患者的同侧眼没有差异(p > 0.5)。在 53 例双侧假性角膜病变患者中,激光耀斑光度计与同侧眼无明显差异(p < 0.05)。视觉效果良好,人工晶体在眼窝沟内的定位和耐受性良好。此外,由于没有发现眼压升高或慢性葡萄膜炎的迹象,因此没有安全问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信