The concurrent validity and reliability of the My Jump Lab smartphone app for the real-time measurement of vertical jump performance

IF 1.1 4区 医学 Q4 ENGINEERING, MECHANICAL
Deniz Şentürk, Oğuzhan Yüksel, Zeki Akyildiz
{"title":"The concurrent validity and reliability of the My Jump Lab smartphone app for the real-time measurement of vertical jump performance","authors":"Deniz Şentürk, Oğuzhan Yüksel, Zeki Akyildiz","doi":"10.1177/17543371241246439","DOIUrl":null,"url":null,"abstract":"The present study had two main objectives: (i) to assess the concurrent validity and agreement of real-time measurement of counter-movement jump (CMJ) height using the My Jump Lab (MJL) mobile application in comparison to a force plate and (ii) to evaluate the intra-session reliability and agreement of the force plate and the MJL application. This cross-sectional investigation involved 36 recreationally active, healthy men (mean age = 22.2 ± 2.9 years) who performed five CMJ repetitions on the force plate with a 2-min rest period. Their jump heights were concurrently recorded using both the force plate and the MJL application. The high validity between the two methods intraclass correlation coefficient >0.984) was observed for all cases. There was a nearly perfect correlation ( r = 0.968, p = 0.001, in all cases) between the force plate and MJL application, with very good agreement and a mean difference of 1.016 cm (95% confidence interval: −1.229 to −0.803 cm). High intra-session reliability was observed in the force platform (SEM, 0.42 cm; CV, 1.21%; MDC, 1.5; SWC, 1.12), and MJL (SEM, 0.43 cm; CV, 1.23%; MDC, 1.20; SWC, 1.17). The results demonstrate that the MJL application is a valid and reliable tool for measuring jump performance in real-time and assessing CMJ height.","PeriodicalId":20674,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology","volume":"42 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/17543371241246439","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The present study had two main objectives: (i) to assess the concurrent validity and agreement of real-time measurement of counter-movement jump (CMJ) height using the My Jump Lab (MJL) mobile application in comparison to a force plate and (ii) to evaluate the intra-session reliability and agreement of the force plate and the MJL application. This cross-sectional investigation involved 36 recreationally active, healthy men (mean age = 22.2 ± 2.9 years) who performed five CMJ repetitions on the force plate with a 2-min rest period. Their jump heights were concurrently recorded using both the force plate and the MJL application. The high validity between the two methods intraclass correlation coefficient >0.984) was observed for all cases. There was a nearly perfect correlation ( r = 0.968, p = 0.001, in all cases) between the force plate and MJL application, with very good agreement and a mean difference of 1.016 cm (95% confidence interval: −1.229 to −0.803 cm). High intra-session reliability was observed in the force platform (SEM, 0.42 cm; CV, 1.21%; MDC, 1.5; SWC, 1.12), and MJL (SEM, 0.43 cm; CV, 1.23%; MDC, 1.20; SWC, 1.17). The results demonstrate that the MJL application is a valid and reliable tool for measuring jump performance in real-time and assessing CMJ height.
用于实时测量垂直跳跃成绩的 "我的跳跃实验室 "智能手机应用程序的并发有效性和可靠性
本研究有两个主要目标:(i) 评估使用 "我的跳跃实验室"(MJL)移动应用程序实时测量逆向移动跳跃(CMJ)高度与测力板测量的并发有效性和一致性;(ii) 评估测力板和 MJL 应用程序的会内可靠性和一致性。这项横断面调查涉及 36 名参加娱乐活动的健康男性(平均年龄 = 22.2 ± 2.9 岁),他们在测力板上重复进行了五次 CMJ,休息时间为 2 分钟。同时使用测力板和 MJL 应用程序记录他们的跳跃高度。在所有情况下,两种方法的类内相关系数均为 0.984,具有很高的有效性。测力板和 MJL 应用之间几乎完全相关(r = 0.968,p = 0.001,在所有情况下),一致性非常好,平均差异为 1.016 厘米(95% 置信区间:-1.229 至 -0.803 厘米)。在测力平台(SEM,0.42 厘米;CV,1.21%;MDC,1.5;SWC,1.12)和 MJL(SEM,0.43 厘米;CV,1.23%;MDC,1.20;SWC,1.17)中观察到了较高的时段内可靠性。结果表明,MJL 应用程序是实时测量跳跃成绩和评估 CMJ 高度的有效而可靠的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
20.00%
发文量
51
审稿时长
>12 weeks
期刊介绍: The Journal of Sports Engineering and Technology covers the development of novel sports apparel, footwear, and equipment; and the materials, instrumentation, and processes that make advances in sports possible.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信