Rescue technique for basket impaction with a plastic stent, a rare complication of biliary inside stenting

IF 5 2区 医学 Q1 GASTROENTEROLOGY & HEPATOLOGY
Nao Fujimori, Akihisa Ohno, Keijiro Ueda
{"title":"Rescue technique for basket impaction with a plastic stent, a rare complication of biliary inside stenting","authors":"Nao Fujimori,&nbsp;Akihisa Ohno,&nbsp;Keijiro Ueda","doi":"10.1111/den.14798","DOIUrl":null,"url":null,"abstract":"<p>A basket impaction during stone extraction or plastic stent (PS) migration is a well-known complication of endoscopic retrograde cholangiopancreatography (ERCP). However, a basket impaction with a PS is rare. A 66-year-old woman with a 7F biliary inside stent (IS) for the anastomotic biliary stricture after a living donor liver transplantation underwent ERCP for IS exchange. The nylon thread attached to the IS was not found on the endoscopic image. Therefore, we inserted a rotatable 8-wire basket (RASEN; Kaneka Medical, Osaka, Japan) to retrieve the migrated IS.<span><sup>1</sup></span> The IS's distal flange was easily caught by the basket, and we intended to remove it. However, when attempting to extract the IS into the duodenum, the stent's distal end penetrated the oral protrusion of the duodenal papilla, apart from the orifice of the bile duct. We could not open the basket or push it upward into the common bile duct, resulting in its impaction with the PS (Fig. 1). After removing the endoscope and leaving the basket in place, we reinserted the endoscope and recannulated the bile duct. Subsequently, we performed endoscopic sphincterotomy (EST) in the direction of the impacted PS. Although there was post-EST bleeding, we grasped it with forceps after hemostasis and finally succeeded in retrieving the impacted PS (Video S1).</p><p>Various techniques, such as a basket catheter, snare, forceps, balloon catheter, or stent retriever, have been used to retrieve a migrated PS.<span><sup>2</sup></span> However, a rescue technique for an impacted PS has not been established, and complicated procedures such as mechanical lithotripsy or electrohydraulic lithotripsy with a cholangioscope<span><sup>3</sup></span> that have been used for basket impaction with a biliary stone cannot be employed for PS impaction. Endoscopists should carefully align the PS with the direction of stent removal, and additional EST may be a treatment option for PS impaction.</p><p>Author N.F. has received consulting fees from Kaneka Medical, and payment for lectures from Gadelius Medical and Kaneka Medical. The other authors declare no conflict of interest for this article.</p>","PeriodicalId":159,"journal":{"name":"Digestive Endoscopy","volume":null,"pages":null},"PeriodicalIF":5.0000,"publicationDate":"2024-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/den.14798","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive Endoscopy","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/den.14798","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

A basket impaction during stone extraction or plastic stent (PS) migration is a well-known complication of endoscopic retrograde cholangiopancreatography (ERCP). However, a basket impaction with a PS is rare. A 66-year-old woman with a 7F biliary inside stent (IS) for the anastomotic biliary stricture after a living donor liver transplantation underwent ERCP for IS exchange. The nylon thread attached to the IS was not found on the endoscopic image. Therefore, we inserted a rotatable 8-wire basket (RASEN; Kaneka Medical, Osaka, Japan) to retrieve the migrated IS.1 The IS's distal flange was easily caught by the basket, and we intended to remove it. However, when attempting to extract the IS into the duodenum, the stent's distal end penetrated the oral protrusion of the duodenal papilla, apart from the orifice of the bile duct. We could not open the basket or push it upward into the common bile duct, resulting in its impaction with the PS (Fig. 1). After removing the endoscope and leaving the basket in place, we reinserted the endoscope and recannulated the bile duct. Subsequently, we performed endoscopic sphincterotomy (EST) in the direction of the impacted PS. Although there was post-EST bleeding, we grasped it with forceps after hemostasis and finally succeeded in retrieving the impacted PS (Video S1).

Various techniques, such as a basket catheter, snare, forceps, balloon catheter, or stent retriever, have been used to retrieve a migrated PS.2 However, a rescue technique for an impacted PS has not been established, and complicated procedures such as mechanical lithotripsy or electrohydraulic lithotripsy with a cholangioscope3 that have been used for basket impaction with a biliary stone cannot be employed for PS impaction. Endoscopists should carefully align the PS with the direction of stent removal, and additional EST may be a treatment option for PS impaction.

Author N.F. has received consulting fees from Kaneka Medical, and payment for lectures from Gadelius Medical and Kaneka Medical. The other authors declare no conflict of interest for this article.

Abstract Image

胆道内支架手术罕见并发症--塑料支架篮嵌顿的抢救技术
观看本文视频。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Digestive Endoscopy
Digestive Endoscopy 医学-外科
CiteScore
10.10
自引率
15.10%
发文量
291
审稿时长
6-12 weeks
期刊介绍: Digestive Endoscopy (DEN) is the official journal of the Japan Gastroenterological Endoscopy Society, the Asian Pacific Society for Digestive Endoscopy and the World Endoscopy Organization. Digestive Endoscopy serves as a medium for presenting original articles that offer significant contributions to knowledge in the broad field of endoscopy. The Journal also includes Reviews, Original Articles, How I Do It, Case Reports (only of exceptional interest and novelty are accepted), Letters, Techniques and Images, abstracts and news items that may be of interest to endoscopists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信