Coil entrapment in temporary stent-assisted coiling of wide-neck aneurysm: a case report

IF 0.7 Q4 CLINICAL NEUROLOGY
Farid Qoorchi Moheb Seraj, Feizollah Ebrahimnia, Sajjad Najafi, Mahla Esmaeilzadeh, Humain Baharvahdat
{"title":"Coil entrapment in temporary stent-assisted coiling of wide-neck aneurysm: a case report","authors":"Farid Qoorchi Moheb Seraj, Feizollah Ebrahimnia, Sajjad Najafi, Mahla Esmaeilzadeh, Humain Baharvahdat","doi":"10.1186/s41984-024-00280-x","DOIUrl":null,"url":null,"abstract":"Endovascular treatment of the wide-necked aneurysm is still challenging. Temporary stent-assisted coiling (TSAC) was introduced to manage the ruptured wide-necked aneurysms to avoid the long-term use of dual antiplatelets as well as improving aneurysm filling with coils. Here, we reported a case of the coil entrapment into the stent device during TSAC for the treatment of a wide-necked large ruptured aneurysm. Patient presented with loss of consciousness following diffuse subarachnoid hemorrhage due to a wide-necked large aneurysm located in the left ICA bifurcation. During treatment of aneurysm with TSAC technique, the stent could not retrieve and re-sheath because of coil entrapment in the stent struts. Consequently, the stent was released by cutting the pushing wire at the puncture site. Entrapment of coils in the stent struts is a very rare technical complication of TSAC method. It is essential to be aware of this side effect and how to avoid.","PeriodicalId":72881,"journal":{"name":"Egyptian journal of neurosurgery","volume":"32 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian journal of neurosurgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41984-024-00280-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Endovascular treatment of the wide-necked aneurysm is still challenging. Temporary stent-assisted coiling (TSAC) was introduced to manage the ruptured wide-necked aneurysms to avoid the long-term use of dual antiplatelets as well as improving aneurysm filling with coils. Here, we reported a case of the coil entrapment into the stent device during TSAC for the treatment of a wide-necked large ruptured aneurysm. Patient presented with loss of consciousness following diffuse subarachnoid hemorrhage due to a wide-necked large aneurysm located in the left ICA bifurcation. During treatment of aneurysm with TSAC technique, the stent could not retrieve and re-sheath because of coil entrapment in the stent struts. Consequently, the stent was released by cutting the pushing wire at the puncture site. Entrapment of coils in the stent struts is a very rare technical complication of TSAC method. It is essential to be aware of this side effect and how to avoid.
宽颈动脉瘤临时支架辅助卷绕术中的线圈夹层:一份病例报告
宽颈动脉瘤的血管内治疗仍具有挑战性。临时支架辅助卷曲(TSAC)被引入到宽颈动脉瘤破裂的治疗中,以避免长期使用双联抗血小板药物,并通过线圈改善动脉瘤充盈。在此,我们报告了一例在 TSAC 治疗宽颈巨大破裂动脉瘤的过程中线圈卡入支架装置的病例。患者因左侧 ICA 分叉处的宽颈大动脉瘤导致弥漫性蛛网膜下腔出血而失去知觉。在使用 TSAC 技术治疗动脉瘤的过程中,由于支架支柱中的线圈被卡住,支架无法收回和重新出鞘。因此,通过切断穿刺部位的推送线,支架得以释放。线圈卡在支架支柱中是 TSAC 方法中非常罕见的技术并发症。了解这种副作用以及如何避免非常重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
32 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信