{"title":"A STUDY TO COMPARE EFFICACY OF DISINFECTANTS AGAINST STAPHYLOCOCCUS AUREUS IN UNIVERSITI SAINS ISLAM MALAYSIA","authors":"Tine Martina Winarti, Nurul Azmawati Mohamed, Nur Amirah Ab Aziz, Nurul A’mirah Ahmad Lotfi","doi":"10.54052/jhds.v3n3.p333-344","DOIUrl":null,"url":null,"abstract":"Different levels of active ingredients in disinfectants can be classified into three levels of disinfectants. Low-level and low-to-intermediate level disinfectants are commonly used in clinical contact surfaces, while high-level disinfectants are used on submerged inanimate objects that are heat sensitive. This study aimed to compare the disinfection efficacy of different disinfectants used in USIM Dental Polyclinic on rough and smooth surfaces against Staphylococcus aureusisolated from USIM Dental Polyclinic. 19 operators were enrolled to get 19 environmentalsamples from the glove-dominant hand after non-surgical extraction in the Oral Surgery Clinic. Staphylococcus aureus wasidentified, and an antibiotic susceptibility test was done to determine the methicillin-esistant Staphylococcus aureus(MRSA) strain. Two different levels of disinfectants for the disinfection of dental chairs were tested on rough and smooth surfaces that were contaminated experimentally by Staphylococcus aureus. The number of colonies without and after disinfection was counted, and the reduction percentagewas calculated and analyzed.Staphylococcus aureuswas detected in 68.42% (n=13) of the samples. 5.26% (n=1) of the samples were Staphylococcus sp. 26.32% (n=5) had no bacterial growth. No methicillin-resistant Staphylococcus aureusstrain was identified. There was no statistically significant difference (p>0.05) between the efficacy of the three disinfectants from two different levels used in USIM Dental Polyclinic on rough and smooth surfaces against Staphylococcus aureus. Theefficacy of different levels of disinfectants used in USIM Dental Polyclinic was comparable to each other on rough and smooth surfaces against Staphylococcus aureus","PeriodicalId":400810,"journal":{"name":"Journal of Health and Dental Sciences","volume":"48 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Health and Dental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54052/jhds.v3n3.p333-344","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Different levels of active ingredients in disinfectants can be classified into three levels of disinfectants. Low-level and low-to-intermediate level disinfectants are commonly used in clinical contact surfaces, while high-level disinfectants are used on submerged inanimate objects that are heat sensitive. This study aimed to compare the disinfection efficacy of different disinfectants used in USIM Dental Polyclinic on rough and smooth surfaces against Staphylococcus aureusisolated from USIM Dental Polyclinic. 19 operators were enrolled to get 19 environmentalsamples from the glove-dominant hand after non-surgical extraction in the Oral Surgery Clinic. Staphylococcus aureus wasidentified, and an antibiotic susceptibility test was done to determine the methicillin-esistant Staphylococcus aureus(MRSA) strain. Two different levels of disinfectants for the disinfection of dental chairs were tested on rough and smooth surfaces that were contaminated experimentally by Staphylococcus aureus. The number of colonies without and after disinfection was counted, and the reduction percentagewas calculated and analyzed.Staphylococcus aureuswas detected in 68.42% (n=13) of the samples. 5.26% (n=1) of the samples were Staphylococcus sp. 26.32% (n=5) had no bacterial growth. No methicillin-resistant Staphylococcus aureusstrain was identified. There was no statistically significant difference (p>0.05) between the efficacy of the three disinfectants from two different levels used in USIM Dental Polyclinic on rough and smooth surfaces against Staphylococcus aureus. Theefficacy of different levels of disinfectants used in USIM Dental Polyclinic was comparable to each other on rough and smooth surfaces against Staphylococcus aureus
比较马来西亚伊斯兰大学消毒剂对金黄色葡萄球菌的功效的研究
消毒剂中的有效成分含量不同,可分为三级消毒剂。低级和中低级消毒剂通常用于临床接触表面,而高级消毒剂则用于对热敏感的浸没无生命物体。本研究旨在比较 USIM 牙科综合诊所使用的不同消毒剂在粗糙和光滑表面上对 USIM 牙科综合诊所分离出的金黄色葡萄球菌的消毒效果。19 名操作人员在口腔外科诊所进行非手术拔牙后,从戴手套的手部采集了 19 份环境样本。对金黄色葡萄球菌进行鉴定,并进行抗生素药敏试验,以确定耐甲氧西林金黄色葡萄球菌(MRSA)菌株。在被金黄色葡萄球菌实验性污染的粗糙和光滑表面上测试了用于牙科椅消毒的两种不同级别的消毒剂。在 68.42%(n=13)的样本中检测到了金黄色葡萄球菌。68.42%(13 个)的样本中检测到金黄色葡萄球菌,5.26%(1 个)的样本中检测到葡萄球菌,26.32%(5 个)的样本中没有细菌生长。没有发现耐甲氧西林金黄色葡萄球菌菌株。USIM 牙科综合诊所使用的两种不同级别的三种消毒剂对粗糙和光滑表面的金黄色葡萄球菌的疗效没有明显的统计学差异(p>0.05)。USIM 口腔综合诊所使用的不同级别消毒剂对粗糙和光滑表面金黄色葡萄球菌的功效相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信