Morphometry of the infraorbital foramen in dentate and edentulous adult humans and its clinical relevance

IF 0.5 4区 农林科学
J. G. Alexander, J. D. S. Baptista
{"title":"Morphometry of the infraorbital foramen in dentate and edentulous adult humans and its clinical relevance","authors":"J. G. Alexander, J. D. S. Baptista","doi":"10.14393/bj-v40n0a2024-68149","DOIUrl":null,"url":null,"abstract":"The infraorbital foramen (IOF) serves as an important anatomical reference for infraorbital nerve block during different procedures. Its clinical and surgical relevance, associated with conflicting results in its anatomy description justifies the present study. Thus, this work aims to describe the IOF, qualitatively and quantitatively, and propose an accurate measurement to define its location. One hundred and seventy-four IOFs of dry skulls were analyzed and divided in dentate (DE) and edentulous (ED) groups. Distances were measured between the IOF and the margin of the alveolar arch of the maxilla (MAAM), the inferior orbital margin (IOM), the intermaxillary suture (IMS), the vertical plane of IOF. A new methodology was proposed to optimize the identification of IOF based on the IMS distance. Oval-shaped IOFs (n=81/174) with inferomedial orientation (n=104/174) and with a crest-shaped upper margin (n=163/174) constituted the norm for this sample. Distance between IOF and MAAM was 29.97 ± 4.09 mm, to IOM 7.27 ± 1.8 mm, and to IMS 35.09 ± 3.77 mm. ED individuals had IOF closer to MAAM (p=0.0124). The highest point of this methodology was the lack of statistical differences in the IMS distance in ED and DE specimens, making this method applicable for both. Therefore, to minimize iatrogenic injuries, clinicians and surgeons must consider the total or partial presence of teeth, the methodology established to find the IOF, its inferomedial orientation, and the prevalent crest on its superior margin.","PeriodicalId":48946,"journal":{"name":"Bioscience Journal","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2024-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioscience Journal","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.14393/bj-v40n0a2024-68149","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The infraorbital foramen (IOF) serves as an important anatomical reference for infraorbital nerve block during different procedures. Its clinical and surgical relevance, associated with conflicting results in its anatomy description justifies the present study. Thus, this work aims to describe the IOF, qualitatively and quantitatively, and propose an accurate measurement to define its location. One hundred and seventy-four IOFs of dry skulls were analyzed and divided in dentate (DE) and edentulous (ED) groups. Distances were measured between the IOF and the margin of the alveolar arch of the maxilla (MAAM), the inferior orbital margin (IOM), the intermaxillary suture (IMS), the vertical plane of IOF. A new methodology was proposed to optimize the identification of IOF based on the IMS distance. Oval-shaped IOFs (n=81/174) with inferomedial orientation (n=104/174) and with a crest-shaped upper margin (n=163/174) constituted the norm for this sample. Distance between IOF and MAAM was 29.97 ± 4.09 mm, to IOM 7.27 ± 1.8 mm, and to IMS 35.09 ± 3.77 mm. ED individuals had IOF closer to MAAM (p=0.0124). The highest point of this methodology was the lack of statistical differences in the IMS distance in ED and DE specimens, making this method applicable for both. Therefore, to minimize iatrogenic injuries, clinicians and surgeons must consider the total or partial presence of teeth, the methodology established to find the IOF, its inferomedial orientation, and the prevalent crest on its superior margin.
有牙和无牙成年人眶下孔的形态测量及其临床意义
眶下孔(IOF)是不同手术中眶下神经阻滞的重要解剖参考。眶下孔与临床和外科手术息息相关,但对其解剖描述的结果却相互矛盾,这就证明了本研究的合理性。因此,本研究旨在对 IOF 进行定性和定量描述,并提出准确的测量方法来确定其位置。研究人员分析了 174 个干燥头骨的 IOF,并将其分为有齿组(DE)和无齿组(ED)。测量了IOF与上颌牙槽弓边缘(MAAM)、眶下缘(IOM)、颌间缝(IMS)和IOF垂直面之间的距离。我们提出了一种新方法,根据 IMS 的距离优化 IOF 的识别。椭圆形的IOF(n=81/174)、内侧向的IOF(n=104/174)和上缘呈嵴状的IOF(n=163/174)构成了该样本的标准。IOF与MAAM的距离为29.97 ± 4.09 mm,与IOM的距离为7.27 ± 1.8 mm,与IMS的距离为35.09 ± 3.77 mm。ED患者的IOF更接近MAAM(P=0.0124)。该方法的最大优点是 ED 和 DE 标本的 IMS 距离没有统计学差异,因此该方法适用于这两种标本。因此,为了尽量减少先天性损伤,临床医生和外科医生必须考虑牙齿的全部或部分存在、寻找 IOF 的方法、IOF 的内侧方向及其上缘的流行嵴。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Bioscience Journal
Bioscience Journal AGRICULTURE, MULTIDISCIPLINARY-AGRONOMY
CiteScore
1.10
自引率
0.00%
发文量
90
期刊介绍: The Bioscience Journal is an interdisciplinary electronic journal that publishes scientific articles in the areas of Agricultural Sciences, Biological Sciences and Health Sciences. Its mission is to disseminate new knowledge while contributing to the development of science in the country and in the world. The journal is published in a continuous flow, in English. The opinions and concepts expressed in the published articles are the sole responsibility of their authors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信