Self-characterization of irradiation facility using synthetic multi-element standard for determination of k0-factors of seven radionuclides of interest

Phonesavanh Lathdavong, Ho Manh Dung, Hồ Văn Doanh, T. Q. Thiện, Trương Trường Sơn
{"title":"Self-characterization of irradiation facility using synthetic multi-element standard for determination of k0-factors of seven radionuclides of interest","authors":"Phonesavanh Lathdavong, Ho Manh Dung, Hồ Văn Doanh, T. Q. Thiện, Trương Trường Sơn","doi":"10.53747/nst.v13i1.402","DOIUrl":null,"url":null,"abstract":"In this study, the k0 factors of 7 short and medium-lived radionuclides (i.e. 66Cu, 52V, 38Cl, 134mCs, 128I, 140La and 56Mn) were experimentally determined at the Dalat nuclear research reactor (DNRR). The synthetic multi-element standard (SMELS) samples were irradiated at Channel 7-1 installed at the DNRR. SMELS Type III contains Au and Zr, thus also allowing the self-characterization of the irradiation facility (i.e. the direct determination of f and a with only this material). The k0 factors of 7 short and medium-lived radionuclides obtained in this work are a good agreement with the reference k0 factors. The ratio values between the experimental and reference k0 values were 66Cu of 1.004, 52V of 1.004, 38Cl of 0.961 and 0.976 (1642.7 keV and 2167.4keV, respectively), 134mCs of 0.831, 128I of 1.022, 140La of 0.936, 0.955 and 0.955 (328.8 keV, 487.0 keV and 1596.2keV, respectively), 56Mn of 0.985 and 0.973 (846.8 keV and 1810.7keV, respectively). The radionuclides range of uncertainty values were lower than 7%. The present result indicates that the k0 factors can be determined by using synthetic multi-element standards (SMELS).","PeriodicalId":19445,"journal":{"name":"Nuclear Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53747/nst.v13i1.402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, the k0 factors of 7 short and medium-lived radionuclides (i.e. 66Cu, 52V, 38Cl, 134mCs, 128I, 140La and 56Mn) were experimentally determined at the Dalat nuclear research reactor (DNRR). The synthetic multi-element standard (SMELS) samples were irradiated at Channel 7-1 installed at the DNRR. SMELS Type III contains Au and Zr, thus also allowing the self-characterization of the irradiation facility (i.e. the direct determination of f and a with only this material). The k0 factors of 7 short and medium-lived radionuclides obtained in this work are a good agreement with the reference k0 factors. The ratio values between the experimental and reference k0 values were 66Cu of 1.004, 52V of 1.004, 38Cl of 0.961 and 0.976 (1642.7 keV and 2167.4keV, respectively), 134mCs of 0.831, 128I of 1.022, 140La of 0.936, 0.955 and 0.955 (328.8 keV, 487.0 keV and 1596.2keV, respectively), 56Mn of 0.985 and 0.973 (846.8 keV and 1810.7keV, respectively). The radionuclides range of uncertainty values were lower than 7%. The present result indicates that the k0 factors can be determined by using synthetic multi-element standards (SMELS).
利用合成多元素标准测定七种相关放射性核素的 k0 因子,实现辐照设施的自我特征描述
本研究在达叻核研究反应堆(DNRR)对 7 种中短寿命放射性核素(即 66Cu、52V、38Cl、134mCs、128I、140La 和 56Mn)的 k0 因子进行了实验测定。合成多元素标准(SMELS)样品在达叻核研究反应堆安装的 7-1 频道进行辐照。SMELS III 型含有金和锆,因此也允许对辐照设施进行自我表征(即只用这种材料直接测定 f 和 a)。这项工作获得的 7 种中短寿命放射性核素的 k0 因子与参考 k0 因子非常吻合。实验值与参考 k0 值的比值分别为:66Cu 为 1.004、52V 为 1.004、38Cl 为 0.961 和 0.976(分别为 1642.7 keV 和 2167.4 keV)、134mCs 为 0.831、128I 为 1.831(分别为 1642.7 keV 和 2167.4 keV)。831, 128I of 1.022, 140La of 0.936, 0.955 and 0.955 (分别为 328.8 keV, 487.0 keV and 1596.2 keV), 56Mn of 0.985 and 0.973 (分别为 846.8 keV and 1810.7 keV)。放射性核素的不确定值范围均低于 7%。本结果表明,使用合成多元素标准(SMELS)可以确定 k0 因子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信