A Near-Field Imaging Method Based on the Near-Field Distance for an Aperture Synthesis Radiometer

Remote. Sens. Pub Date : 2024-02-22 DOI:10.3390/rs16050767
Yuanchao Wu, Yinan Li, Guangnan Song, Haofeng Dou, Dandan Wen, Pengfei Li, Xiaojiao Yang, Rongchuan Lv, Hao Li
{"title":"A Near-Field Imaging Method Based on the Near-Field Distance for an Aperture Synthesis Radiometer","authors":"Yuanchao Wu, Yinan Li, Guangnan Song, Haofeng Dou, Dandan Wen, Pengfei Li, Xiaojiao Yang, Rongchuan Lv, Hao Li","doi":"10.3390/rs16050767","DOIUrl":null,"url":null,"abstract":"For an aperture synthesis radiometer (ASR), the visibility and the modified brightness temperature (BT) are related to the Fourier transform when the distance between the system and the source is in the far-field region. BT reconstruction can be achieved using G-matrix imaging. However, for ASRs with large array sizes, the far-field condition is not satisfied when performing performance tests in an anechoic chamber due to size limitations. Using far-field imaging methods in near-field conditions can introduce errors in the images and fail to correctly reconstruct the BT. Most of the existing methods deal with visibilities, converting near-field visibilities to far-field visibilities, which are suitable for point sources but not good for extended source correction. In this paper, two near-field imaging methods are proposed based on the near-field distance. These methods enable BT reconstruction in near-field conditions by generating improved resolving matrices: the near-field G-matrix and the F-matrix. These methods do not change the visibility measurements and can effectively image both the point source and the extended source in the near field. Simulations of point sources and extended sources in near-field conditions demonstrate the effectiveness of both methods, with F-matrix imaging outperforming near-field G-matrix imaging. The feasibility of both near-field imaging methods is further validated by carrying out experiments on a 10-element Y-array system.","PeriodicalId":20944,"journal":{"name":"Remote. Sens.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Remote. Sens.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/rs16050767","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

For an aperture synthesis radiometer (ASR), the visibility and the modified brightness temperature (BT) are related to the Fourier transform when the distance between the system and the source is in the far-field region. BT reconstruction can be achieved using G-matrix imaging. However, for ASRs with large array sizes, the far-field condition is not satisfied when performing performance tests in an anechoic chamber due to size limitations. Using far-field imaging methods in near-field conditions can introduce errors in the images and fail to correctly reconstruct the BT. Most of the existing methods deal with visibilities, converting near-field visibilities to far-field visibilities, which are suitable for point sources but not good for extended source correction. In this paper, two near-field imaging methods are proposed based on the near-field distance. These methods enable BT reconstruction in near-field conditions by generating improved resolving matrices: the near-field G-matrix and the F-matrix. These methods do not change the visibility measurements and can effectively image both the point source and the extended source in the near field. Simulations of point sources and extended sources in near-field conditions demonstrate the effectiveness of both methods, with F-matrix imaging outperforming near-field G-matrix imaging. The feasibility of both near-field imaging methods is further validated by carrying out experiments on a 10-element Y-array system.
基于孔径合成辐射计近场距离的近场成像方法
对于孔径合成辐射计(ASR)来说,当系统与光源之间的距离处于远场区域时,可见度和修正亮度温度(BT)与傅立叶变换有关。BT 重建可通过 G 矩阵成像来实现。然而,对于阵列尺寸较大的 ASR,由于尺寸限制,在电波暗室中进行性能测试时无法满足远场条件。在近场条件下使用远场成像方法会在图像中引入误差,无法正确重建 BT。现有的大多数方法都是处理可见度,将近场可见度转换为远场可见度,这些方法适用于点源,但不利于扩展源校正。本文提出了两种基于近场距离的近场成像方法。这些方法通过生成改进的解析矩阵:近场 G 矩阵和 F 矩阵,在近场条件下进行 BT 重建。这些方法不会改变可见度测量值,能有效地对近场中的点源和扩展源进行成像。在近场条件下对点源和扩展源的模拟证明了这两种方法的有效性,其中 F 矩阵成像优于近场 G 矩阵成像。通过在 10 元 Y 阵列系统上进行实验,进一步验证了这两种近场成像方法的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信