Pedicle Screw Bond Strength and Resistance Characteristics With Various Mineral Quality

TEM Journal Pub Date : 2024-02-27 DOI:10.18421/tem131-83
Weriono Weriono, M. Rusli, R. Sahputra, Hendery Dahlan
{"title":"Pedicle Screw Bond Strength and Resistance Characteristics With Various Mineral Quality","authors":"Weriono Weriono, M. Rusli, R. Sahputra, Hendery Dahlan","doi":"10.18421/tem131-83","DOIUrl":null,"url":null,"abstract":"Abnormal quality and composition of bone mineral bonds in the spine are found in many patients with cases of idiopathic scoliosis. The data shows that poor bone quality promotes thoracic spine degenerative disc swelling and physiological anomalies. Implants in the form of pedicle screws, rods, and connectors are one of the measures for scoliosis correction. When the pedicle screws are taken out after some use poor bone quality remains. In this study, fixation strength analysis will be carried out through tensile testing of bone joints and pedicle screws with variations in bone quality. Two specimen materials were used for approach analysis: polylactic acid (PLA) and bovine backbone. Pedicle screws are classified into three types: cylindrical, conical with a single thread, and double cylindrical screws. Tensile testing revealed that PLA specimens with pedicle screw variants provided the maximum force of 7.4 N and 8.31 N with double screw cylindrical implants at PLA 70:30 and PLA 40:60. A comparison of PLA specimens with a series of cylindrical screws to double-screw cylindrical screws yielded a displacement increase of 79.6%, whereas conical screws yielded a displacement increase of 222.3%. Fixation with double-screw cylindrical screws greatly increases tensile strength. However, the conical pedicle screw model with connecting rods gives greater fixation strength.","PeriodicalId":515899,"journal":{"name":"TEM Journal","volume":"19 9","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"TEM Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18421/tem131-83","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abnormal quality and composition of bone mineral bonds in the spine are found in many patients with cases of idiopathic scoliosis. The data shows that poor bone quality promotes thoracic spine degenerative disc swelling and physiological anomalies. Implants in the form of pedicle screws, rods, and connectors are one of the measures for scoliosis correction. When the pedicle screws are taken out after some use poor bone quality remains. In this study, fixation strength analysis will be carried out through tensile testing of bone joints and pedicle screws with variations in bone quality. Two specimen materials were used for approach analysis: polylactic acid (PLA) and bovine backbone. Pedicle screws are classified into three types: cylindrical, conical with a single thread, and double cylindrical screws. Tensile testing revealed that PLA specimens with pedicle screw variants provided the maximum force of 7.4 N and 8.31 N with double screw cylindrical implants at PLA 70:30 and PLA 40:60. A comparison of PLA specimens with a series of cylindrical screws to double-screw cylindrical screws yielded a displacement increase of 79.6%, whereas conical screws yielded a displacement increase of 222.3%. Fixation with double-screw cylindrical screws greatly increases tensile strength. However, the conical pedicle screw model with connecting rods gives greater fixation strength.
不同矿物质量的椎弓根螺钉粘接强度和阻力特性
许多特发性脊柱侧弯症患者的脊柱骨矿物质结合质量和组成异常。数据显示,骨质差会导致胸椎退行性椎间盘肿胀和生理异常。椎弓根螺钉、杆和连接器等植入物是矫正脊柱侧弯的措施之一。当椎弓根螺钉在使用一段时间后被取出时,骨质仍然很差。在本研究中,将通过对骨关节和椎弓根螺钉进行拉伸测试来分析不同骨质的固定强度。分析中使用了两种试样材料:聚乳酸(PLA)和牛脊骨。椎弓根螺钉分为三种类型:圆柱螺钉、锥形单螺纹螺钉和双圆柱螺钉。拉伸测试显示,带有椎弓根螺钉变体的聚乳酸试样在聚乳酸70:30和聚乳酸40:60条件下提供的最大力分别为7.4牛顿和8.31牛顿(双螺旋圆柱形植入物)。将带有一系列圆柱形螺钉的聚乳酸试样与双螺旋圆柱形螺钉进行比较,结果发现位移增加了 79.6%,而锥形螺钉的位移增加了 222.3%。使用双螺旋圆柱螺钉固定可大大提高抗拉强度。不过,带有连接杆的锥形椎弓根螺钉模型的固定强度更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信