{"title":"Development and Validation of a Chromatographic Method for Ibrutinib Determination in Human and Porcine Skin","authors":"Lucas F. F. Albuquerque, Maria Victoria Souto, Felipe Saldanha-Araujo, J. L. Carvalho, Taís Gratieri, Marcilio Cunha-Filho, G. Gelfuso","doi":"10.3390/chemistry6020014","DOIUrl":null,"url":null,"abstract":"Ibrutinib (IBR) is a tyrosine kinase inhibitor investigated for treating solid and non-solid tumors. Considering the advantages that a topical application of IBR could generate in terms of dose reduction and side effects in skin cancer treatment, this paper presents a simple and selective HPLC method for determining IBR concentration in in vitro skin permeation studies to support the development of topical formulations. The method uses a reversed-phase C18 column and a mobile phase composed of acetonitrile and 0.01 mol/L phosphoric acid at pH 3.5 (35:65 v/v), flowing at 1.0 mL/min. The oven temperature was set at 35 °C, the injection volume was 20 μL, and UV drug detection was performed at 259 nm. The validation procedure certified that this method was selective for IBR determination even when extracted from human or porcine skin matrices. The method was linear over a range of 0.2 to 15.0 μg/mL, precise, robust, and accurate, with recovery rates from the skin layers higher than 89.5 ± 5.9% for the porcine skin and higher than 92.0 ± 0.2% for the human skin. The limits of detection and quantification were 0.01 and 0.02 μg/mL, respectively. The method showed, therefore, to be adequate for use in further skin permeation studies employing IBR topical formulations.","PeriodicalId":9850,"journal":{"name":"Chemistry","volume":"6 20","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemistry","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.3390/chemistry6020014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 0

Abstract

Ibrutinib (IBR) is a tyrosine kinase inhibitor investigated for treating solid and non-solid tumors. Considering the advantages that a topical application of IBR could generate in terms of dose reduction and side effects in skin cancer treatment, this paper presents a simple and selective HPLC method for determining IBR concentration in in vitro skin permeation studies to support the development of topical formulations. The method uses a reversed-phase C18 column and a mobile phase composed of acetonitrile and 0.01 mol/L phosphoric acid at pH 3.5 (35:65 v/v), flowing at 1.0 mL/min. The oven temperature was set at 35 °C, the injection volume was 20 μL, and UV drug detection was performed at 259 nm. The validation procedure certified that this method was selective for IBR determination even when extracted from human or porcine skin matrices. The method was linear over a range of 0.2 to 15.0 μg/mL, precise, robust, and accurate, with recovery rates from the skin layers higher than 89.5 ± 5.9% for the porcine skin and higher than 92.0 ± 0.2% for the human skin. The limits of detection and quantification were 0.01 and 0.02 μg/mL, respectively. The method showed, therefore, to be adequate for use in further skin permeation studies employing IBR topical formulations.
人和猪皮肤中伊布替尼色谱检测方法的开发与验证
伊布替尼(IBR)是一种酪氨酸激酶抑制剂,被研究用于治疗实体瘤和非实体瘤。考虑到在皮肤癌治疗中局部应用伊布替尼在减少剂量和副作用方面的优势,本文介绍了一种简单、选择性强的高效液相色谱法,用于测定体外皮肤渗透研究中的伊布替尼浓度,以支持局部制剂的开发。该方法采用反相 C18 色谱柱,流动相为 pH 3.5 的乙腈和 0.01 mol/L 磷酸(35:65 v/v),流速为 1.0 mL/min。烘箱温度为 35 °C,进样量为 20 μL,紫外检测波长为 259 nm。验证程序证明,即使从人或猪皮肤基质中提取,该方法也能选择性地测定 IBR。该方法在0.2~15.0 μg/mL范围内线性关系良好,精密、稳健、准确,猪皮的回收率高于89.5 ± 5.9%,人皮的回收率高于92.0 ± 0.2%。检测和定量限分别为 0.01 和 0.02 μg/mL。因此,该方法足以用于采用 IBR 外用制剂的进一步皮肤渗透研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.50
自引率
0.00%
发文量
0
审稿时长
11 weeks
期刊介绍: Chemistry—A European Journal is a truly international journal with top quality contributions (2017 ISI Impact Factor: 5.16). It publishes a wide range of outstanding Reviews, Minireviews, Concepts, Full Papers, and Communications from all areas of chemistry and related fields.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信