Ultrasonic vascular visual-exercise early diagnosis of arterial hypertension

Vrach Pub Date : 2024-03-01 DOI:10.29296/25877305-2024-03-04
V. Avkhimenko, A. Trivozhenko
{"title":"Ultrasonic vascular visual-exercise early diagnosis of arterial hypertension","authors":"V. Avkhimenko, A. Trivozhenko","doi":"10.29296/25877305-2024-03-04","DOIUrl":null,"url":null,"abstract":"High level of prevalence of the arterial hypertension (AH) demands use of new technologies of early disease verification. Purpose. Develop a visual-exercise method of diagnostics of AH: bicycle-stressful doppler sonography of a renal-vascular blood-groove with assessment of the vascular motion status and definition of diagnostic criteria of disease. Materials and methods. The cohort (n=48) of healthy subjects and patients with AH I-II degree is surveyed. Bicycle-stressful research of renal-vascular reactivity included initial measurement and exercise monitoring of peak speed of a blood-groove (Vps) and the resistant index (RI) in renal artery (RA). Calculation the index of the pressor and high-speed relation (IPHSR) on a formula was carried out: IPHSR = Systolic BP/ Vps RA. Results. At peak bicycle-stressful test the VpsRA at patients with AH increased only 8% (2.8–11.0%) while at healthy volunteers – 27% (21.4–37.0%). Significantly differed IPHSR: at patients with AH it was measured 2.38–3.23 units (2.8 [2.650–2.892] units), and healthy volunteers 1.72–2.37 units (2.03 [1.91–2.16] units) (p=0,0001). The sensitivity of IPHSR was 91%, specificity – 88%, accuracy – 93%. The decrease of cortically kidney perfusion (increase in RI RA) in group of control was less expressed, than group of patients with AH: 8,6% (4.3–11.0) and 14.7% (9.7–23.2] respectively (r=0,0004). Conclusion. In the course of bicycle-exercise at patients with AH load the small growth of peak speed (25%), the IPHSR is highly sensitive (91%) and highly specific (88%) criterion of AH with differential border of 2,5 units.","PeriodicalId":23748,"journal":{"name":"Vrach","volume":"351 6","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vrach","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29296/25877305-2024-03-04","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

High level of prevalence of the arterial hypertension (AH) demands use of new technologies of early disease verification. Purpose. Develop a visual-exercise method of diagnostics of AH: bicycle-stressful doppler sonography of a renal-vascular blood-groove with assessment of the vascular motion status and definition of diagnostic criteria of disease. Materials and methods. The cohort (n=48) of healthy subjects and patients with AH I-II degree is surveyed. Bicycle-stressful research of renal-vascular reactivity included initial measurement and exercise monitoring of peak speed of a blood-groove (Vps) and the resistant index (RI) in renal artery (RA). Calculation the index of the pressor and high-speed relation (IPHSR) on a formula was carried out: IPHSR = Systolic BP/ Vps RA. Results. At peak bicycle-stressful test the VpsRA at patients with AH increased only 8% (2.8–11.0%) while at healthy volunteers – 27% (21.4–37.0%). Significantly differed IPHSR: at patients with AH it was measured 2.38–3.23 units (2.8 [2.650–2.892] units), and healthy volunteers 1.72–2.37 units (2.03 [1.91–2.16] units) (p=0,0001). The sensitivity of IPHSR was 91%, specificity – 88%, accuracy – 93%. The decrease of cortically kidney perfusion (increase in RI RA) in group of control was less expressed, than group of patients with AH: 8,6% (4.3–11.0) and 14.7% (9.7–23.2] respectively (r=0,0004). Conclusion. In the course of bicycle-exercise at patients with AH load the small growth of peak speed (25%), the IPHSR is highly sensitive (91%) and highly specific (88%) criterion of AH with differential border of 2,5 units.
超声波血管可视运动对动脉高血压的早期诊断
动脉高血压(AH)发病率高,需要使用新技术进行早期疾病核查。目的。开发一种诊断 AH 的可视化运动方法:对肾血管血槽进行自行车加压多普勒超声检查,评估血管运动状态并确定疾病诊断标准。材料和方法。对健康受试者和 I-II 级 AH 患者(48 人)进行调查。对肾血管反应性的自行车压力研究包括对血槽峰值速度(Vps)和肾动脉(RA)阻力指数(RI)的初始测量和运动监测。根据公式计算出加压和高速关系指数(IPHSR):IPHSR = 收缩压/Vps RA。结果。在自行车压力测试峰值时,AH 患者的 VpsRA 仅增加了 8%(2.8-11.0%),而健康志愿者则增加了 27%(21.4-37.0%)。IPHSR差异显著:AH患者的测量值为2.38-3.23单位(2.8 [2.650-2.892]单位),健康志愿者为1.72-2.37单位(2.03 [1.91-2.16]单位)(P=0,0001)。IPHSR 的灵敏度为 91%,特异度为 88%,准确度为 93%。对照组的皮质肾灌注减少(RI RA 增加)的程度低于 AH 患者组:分别为 8.6% (4.3-11.0) 和 14.7% (9.7-23.2] (r=0,0004)。结论在 AH 患者的自行车运动过程中,峰值速度增长较小(25%),IPHSR 是 AH 的高灵敏度(91%)和高特异性(88%)标准,差异边界为 2.5 个单位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信