Comparative assessment of pupillary oscillation and blinking rate between emmetropes and myopes

Shovna Dash, Soumya Kanta Mohanty, P. Sahu, Sourav Padhee
{"title":"Comparative assessment of pupillary oscillation and blinking rate between emmetropes and myopes","authors":"Shovna Dash, Soumya Kanta Mohanty, P. Sahu, Sourav Padhee","doi":"10.18231/j.ijceo.2024.023","DOIUrl":null,"url":null,"abstract":"Aim of this study was to investigate for a relationship between pupillary oscillations (PO) and blinking rate (B) in various vision deprived states such as in refractive errors (Myopes).: A case control descriptive study with 340 individuals, including 220 myopes and 120 emmetropes were compared for pupillary oscillation rate (PO), blinking rate (B) and Pupillary oscillation/blinking rate (PO/B) ratio bilaterally in normal as well as in individual subgroups of decreasing visual acuity, done under slit lamp in dim diffuse illumination. The pupillary oscillation rate (PO) was 49.23± 8.80 in right eye (POR) and 56.44 ±8.95 in left eye (POL) in the control group whereas it was 46.28 ±11.55 and 52.79 ±11.22 in the right and left eyes respectively of the cases. While PO/B ratio was 12.41±14.11 in the right eye and 14.33±15.9 in the left eye in control group, it was 7.13 ± 7.86 in the right and 8.18 ±9.07 in the left eye of the cases respectively. The blinking rate (B) was 8.62 ±6.06 in the control eyes and in the cases it was 11.69 ±7.91. The comparative analysis of all of the above parameters were statistically significant with p < 0.001 between cases and controls. POR = POL in 5.0%, POR > POL in 7.50% and POR < POL in 87.50%.: This study could be useful in non-verbal patients and comatose patients as diagnostic and prognostic tool, having an implication in different refractive errors and neurological diseases.","PeriodicalId":13485,"journal":{"name":"Indian Journal of Clinical and Experimental Ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Clinical and Experimental Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18231/j.ijceo.2024.023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim of this study was to investigate for a relationship between pupillary oscillations (PO) and blinking rate (B) in various vision deprived states such as in refractive errors (Myopes).: A case control descriptive study with 340 individuals, including 220 myopes and 120 emmetropes were compared for pupillary oscillation rate (PO), blinking rate (B) and Pupillary oscillation/blinking rate (PO/B) ratio bilaterally in normal as well as in individual subgroups of decreasing visual acuity, done under slit lamp in dim diffuse illumination. The pupillary oscillation rate (PO) was 49.23± 8.80 in right eye (POR) and 56.44 ±8.95 in left eye (POL) in the control group whereas it was 46.28 ±11.55 and 52.79 ±11.22 in the right and left eyes respectively of the cases. While PO/B ratio was 12.41±14.11 in the right eye and 14.33±15.9 in the left eye in control group, it was 7.13 ± 7.86 in the right and 8.18 ±9.07 in the left eye of the cases respectively. The blinking rate (B) was 8.62 ±6.06 in the control eyes and in the cases it was 11.69 ±7.91. The comparative analysis of all of the above parameters were statistically significant with p < 0.001 between cases and controls. POR = POL in 5.0%, POR > POL in 7.50% and POR < POL in 87.50%.: This study could be useful in non-verbal patients and comatose patients as diagnostic and prognostic tool, having an implication in different refractive errors and neurological diseases.
近视眼和远视眼瞳孔摆动和眨眼频率的比较评估
本研究旨在调查在各种视力不良状态下,如屈光不正(近视)时,瞳孔振荡(PO)与眨眼率(B)之间的关系:这项病例对照描述性研究有 340 人参加,包括 220 名近视眼患者和 120 名散光眼患者,在昏暗的漫射光下,在裂隙灯下比较了正常人和视力下降的各个亚组的双侧瞳孔振荡率(PO)、眨眼率(B)和瞳孔振荡/眨眼率(PO/B)比值。对照组右眼(POR)和左眼(POL)的瞳孔摆动率(PO)分别为 49.23±8.80 和 56.44±8.95 ,而病例的右眼和左眼分别为 46.28 ±11.55 和 52.79 ±11.22。对照组右眼的 PO/B 比率为(12.41±14.11),左眼为(14.33±15.9),而病例右眼和左眼的 PO/B 比率分别为(7.13±7.86)和(8.18±9.07)。对照组的眨眼率(B)为 8.62 ± 6.06,病例为 11.69 ± 7.91。病例和对照组的上述所有参数的比较分析均有统计学意义(P < 0.001)。POR=POL的占5.0%,POR>POL的占7.50%,POR
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信