Usama Zafar, P. Rai, Ankur Gupta, J.G. Korvink, V. Badilita, Monsur Islam
{"title":"Laser-Induced Copper/Carbon Nanocomposite from Anodically Electrodeposited Chitosan for H2O2 Sensing","authors":"Usama Zafar, P. Rai, Ankur Gupta, J.G. Korvink, V. Badilita, Monsur Islam","doi":"10.3390/c10020028","DOIUrl":null,"url":null,"abstract":"This work presents anodically electrodeposited copper (Cu)/chitosan gel as a novel precursor for synthesizing a Cu/carbon nanocomposite through laser-induced carbonization. Metal/carbon nanocomposites offering advantageous properties compared to their individual counterparts stand out in various applications, particularly in those involving electrochemical phenomena. However, their synthesis often suffers from complicated and time-consuming synthesis procedures. Here, we integrate anodic electrodeposition and laser-induced carbonization to yield a rapid, simple, and inexpensive procedure for synthesizing metal/carbon nanocomposite. A precursor composite involving Cu-coordinated chitosan film is achieved through anodic electrodeposition on a copper anode. Irradiation by an infrared laser with optimized parameters results in the thermochemical decomposition of the Cu/chitosan composite, rapidly forming a nanocomposite material featuring highly graphitized and porous carbon materials. Elemental mapping confirms the formation of the nanocomposite, although no crystalline phases of copper are observed during X-ray diffraction. This can be attributed to the rapid nature of the laser-carbonization process. The nanocomposite material is further demonstrated for electrochemical sensing of hydrogen peroxide (H2O2), exhibiting a sensitivity of 2.65 mM−1 for concentrations ranging from 0.01 mM to 0.1 mM H2O2, and 0.01 ± 0.01 mM−1 for concentrations from 0.1 to 10 mM H2O2. These sensitivities are comparable to other non-enzymatic H2O2 biosensors. The finding of this work signifies a rapid and facile method for synthesizing metal/carbon nanocomposites with strong implications for the field of biosensors.","PeriodicalId":9397,"journal":{"name":"C","volume":" 41","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"C","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/c10020028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This work presents anodically electrodeposited copper (Cu)/chitosan gel as a novel precursor for synthesizing a Cu/carbon nanocomposite through laser-induced carbonization. Metal/carbon nanocomposites offering advantageous properties compared to their individual counterparts stand out in various applications, particularly in those involving electrochemical phenomena. However, their synthesis often suffers from complicated and time-consuming synthesis procedures. Here, we integrate anodic electrodeposition and laser-induced carbonization to yield a rapid, simple, and inexpensive procedure for synthesizing metal/carbon nanocomposite. A precursor composite involving Cu-coordinated chitosan film is achieved through anodic electrodeposition on a copper anode. Irradiation by an infrared laser with optimized parameters results in the thermochemical decomposition of the Cu/chitosan composite, rapidly forming a nanocomposite material featuring highly graphitized and porous carbon materials. Elemental mapping confirms the formation of the nanocomposite, although no crystalline phases of copper are observed during X-ray diffraction. This can be attributed to the rapid nature of the laser-carbonization process. The nanocomposite material is further demonstrated for electrochemical sensing of hydrogen peroxide (H2O2), exhibiting a sensitivity of 2.65 mM−1 for concentrations ranging from 0.01 mM to 0.1 mM H2O2, and 0.01 ± 0.01 mM−1 for concentrations from 0.1 to 10 mM H2O2. These sensitivities are comparable to other non-enzymatic H2O2 biosensors. The finding of this work signifies a rapid and facile method for synthesizing metal/carbon nanocomposites with strong implications for the field of biosensors.