A differential amplitude variation based pilot relaying scheme for microgrid integrated distribution system

IF 0.8 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC
B. Deshmukh, Deepak Kumar Lal, S. Biswal, S. Salkuti
{"title":"A differential amplitude variation based pilot relaying scheme for microgrid integrated distribution system","authors":"B. Deshmukh, Deepak Kumar Lal, S. Biswal, S. Salkuti","doi":"10.1515/ijeeps-2023-0444","DOIUrl":null,"url":null,"abstract":"\n The inclusion of inverter-interfaced distributed generating sources (IIDGS) in the active distribution network offers operational and protection constraints. Dynamic fault behavior of these DGS results in changes like the radial distribution systems. Thus, conventional protection schemes fail to discriminate the in-zone and out-zone faults. Hence, this manuscript describes a new protection scheme based on current variation at the relay location used to discriminate the internal and external faults. This technique requires phasor information of the current signals of both ends and adjacent lines using micro phasor measurement units (µPMUs). Using the current phasor information two components named internal and external are computed at the relay location which is called differential amplitude variation index (DAVI), used to identify the internal and external faults. A modified two-feeder radial distribution network and modified IEEE-13 bus test systems are modeled using EMTDC/PSCAD to validate the proposed strategy. Numerous disturbance cases have been simulated and the feasibility and applicability attributes of the suggested method are verified from the results.","PeriodicalId":45651,"journal":{"name":"International Journal of Emerging Electric Power Systems","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Emerging Electric Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/ijeeps-2023-0444","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The inclusion of inverter-interfaced distributed generating sources (IIDGS) in the active distribution network offers operational and protection constraints. Dynamic fault behavior of these DGS results in changes like the radial distribution systems. Thus, conventional protection schemes fail to discriminate the in-zone and out-zone faults. Hence, this manuscript describes a new protection scheme based on current variation at the relay location used to discriminate the internal and external faults. This technique requires phasor information of the current signals of both ends and adjacent lines using micro phasor measurement units (µPMUs). Using the current phasor information two components named internal and external are computed at the relay location which is called differential amplitude variation index (DAVI), used to identify the internal and external faults. A modified two-feeder radial distribution network and modified IEEE-13 bus test systems are modeled using EMTDC/PSCAD to validate the proposed strategy. Numerous disturbance cases have been simulated and the feasibility and applicability attributes of the suggested method are verified from the results.
基于差分振幅变化的微电网集成配电系统先导继电方案
在有源配电网络中加入逆变器互联分布式发电设备(IIDGS)会带来运行和保护方面的限制。这些 DGS 的动态故障行为会导致像径向配电系统一样的变化。因此,传统的保护方案无法区分区内和区外故障。因此,本手稿介绍了一种基于继电器位置电流变化的新型保护方案,用于区分区内和区外故障。这项技术需要使用微型相位测量单元 (µPMU),获得两端和相邻线路的电流信号相位信息。利用电流相位信息,在继电器位置计算出名为内部和外部的两个分量,称为差幅变化指数 (DAVI),用于识别内部和外部故障。使用 EMTDC/PSCAD 对改进的双馈线径向配电网络和改进的 IEEE-13 总线测试系统进行建模,以验证所提出的策略。模拟了大量干扰情况,并从结果中验证了建议方法的可行性和适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Emerging Electric Power Systems
International Journal of Emerging Electric Power Systems ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
3.00
自引率
10.00%
发文量
63
期刊介绍: International Journal of Emerging Electric Power Systems (IJEEPS) publishes significant research and scholarship related to latest and up-and-coming developments in power systems. The mandate of the journal is to assemble high quality papers from the recent research and development efforts in new technologies and techniques for generation, transmission, distribution and utilization of electric power. Topics The range of topics includes: electric power generation sources integration of unconventional sources into existing power systems generation planning and control new technologies and techniques for power transmission, distribution, protection, control and measurement power system analysis, economics, operation and stability deregulated power systems power system communication metering technologies demand-side management industrial electric power distribution and utilization systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信