{"title":"Evaluation of using hardening soil model for predicting wall deflections caused by deep excavation: A case study at the Ho Chi Minh metro line 1, Vietnam","authors":"Luc Manh Bui, Li Wu, Yao Cheng, Dao Jun Dong","doi":"10.24425/ace.2024.148916","DOIUrl":null,"url":null,"abstract":"The goal of this study is to assess the application of the Hardening soil model in predicting the deformation of retaining walls of excavations in 2D and 3D finite element analysis at the Ho Chi Minh Metro project. Designed as the deepest underground station in the first metro line built in Ho Chi Minh City (HCMC), Opera House station is located in an area with a dense building zone and close to historical buildings. A summary of the input soil properties is provided using data from site investigations, in-situ tests, and laboratory tests. By numerical simulation using the Hardening soil model, the parameters of the soil stiffness modulus value are verified based on the Standard Penetration Test (SPT), and Pressuremeter test (PMT). The obtained results of the numerical analysis by 2D and 3D finite element methods, and field observations indicate that applying the Hardening soil model with soil stiffness modulus obtained in situ tests gives reasonable results on the displacement of the retaining wall at the final phase. The relationship between the SPT value and the stiffness modulus of HCMC sand is a function of depth. This correlation is obtained through the comparison of wall deformation between the simulation and monitoring at the construction site. The results of the difference between 2D and 3D finite element analysis also are discussed in this study.","PeriodicalId":45753,"journal":{"name":"Archives of Civil Engineering","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/ace.2024.148916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

The goal of this study is to assess the application of the Hardening soil model in predicting the deformation of retaining walls of excavations in 2D and 3D finite element analysis at the Ho Chi Minh Metro project. Designed as the deepest underground station in the first metro line built in Ho Chi Minh City (HCMC), Opera House station is located in an area with a dense building zone and close to historical buildings. A summary of the input soil properties is provided using data from site investigations, in-situ tests, and laboratory tests. By numerical simulation using the Hardening soil model, the parameters of the soil stiffness modulus value are verified based on the Standard Penetration Test (SPT), and Pressuremeter test (PMT). The obtained results of the numerical analysis by 2D and 3D finite element methods, and field observations indicate that applying the Hardening soil model with soil stiffness modulus obtained in situ tests gives reasonable results on the displacement of the retaining wall at the final phase. The relationship between the SPT value and the stiffness modulus of HCMC sand is a function of depth. This correlation is obtained through the comparison of wall deformation between the simulation and monitoring at the construction site. The results of the difference between 2D and 3D finite element analysis also are discussed in this study.
使用硬化土壤模型预测深层开挖引起的墙体偏移的评估:越南胡志明地铁 1 号线案例研究
本研究的目的是评估硬化土壤模型在胡志明地铁项目二维和三维有限元分析中预测开挖挡土墙变形中的应用。歌剧院站是胡志明市(HCMC)第一条地铁线中最深的地下车站,位于建筑密集区,毗邻历史建筑。利用现场调查、原位测试和实验室测试的数据,提供了输入土壤特性的概要。通过使用硬化土壤模型进行数值模拟,根据标准渗透试验(SPT)和压力计试验(PMT)验证了土壤刚度模量值的参数。通过二维和三维有限元方法进行的数值分析结果以及现场观察结果表明,应用硬化土壤模型和原位测试获得的土壤刚度模量,可对挡土墙在最后阶段的位移得出合理的结果。HCMC 砂的 SPT 值与刚度模量之间的关系是深度的函数。这种相关性是通过比较模拟和施工现场监测的墙体变形而得出的。本研究还讨论了二维和三维有限元分析的差异结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Archives of Civil Engineering
Archives of Civil Engineering ENGINEERING, CIVIL-
CiteScore
1.50
自引率
28.60%
发文量
0
审稿时长
24 weeks
期刊介绍: ARCHIVES OF CIVIL ENGINEERING publish original papers of the theoretical, experimental, numerical and practical nature in the fields of structural mechanics, soil mechanics and foundations engineering, concrete, metal, timber and composite polymer structures, hydrotechnical structures, roads, railways and bridges, building services, building physics, management in construction, production of construction materials, construction of civil engineering structures, education of civil engineers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信