R. Rahnavard, H.D. Craveiro, R.A. Simões, A. Santiago, L. Laím, L. Gardner
{"title":"BUILT-UP COLD-FORMED STEEL-LIGHTWEIGHT CONCRETE (CFS-LWC) COMPOSITE BEAMS SUBJECTED TO ELEVATED TEMPERATURES","authors":"R. Rahnavard, H.D. Craveiro, R.A. Simões, A. Santiago, L. Laím, L. Gardner","doi":"10.1002/cepa.3037","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Cold-formed steel (CFS) products are extremely versatile and can be used in multiple applications. Recent experiments tests by the authors have shown that mobilising composite action within systems comprising cold-formed steel beams and lightweight concrete is feasible and can lead to substantial improvements in structural performance. However, their behaviour subjected to elevated temperatures has yet to be investigated; this is, therefore, the focus of the present study. The results of two tests on CFS-LWC beams at ambient and elevated temperatures are reported. A numerical modelling study using fire dynamics simulator (FDS) software is then described in which the temperature development was successfully replicated.</p>\n </div>","PeriodicalId":100223,"journal":{"name":"ce/papers","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cepa.3037","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ce/papers","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cepa.3037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Cold-formed steel (CFS) products are extremely versatile and can be used in multiple applications. Recent experiments tests by the authors have shown that mobilising composite action within systems comprising cold-formed steel beams and lightweight concrete is feasible and can lead to substantial improvements in structural performance. However, their behaviour subjected to elevated temperatures has yet to be investigated; this is, therefore, the focus of the present study. The results of two tests on CFS-LWC beams at ambient and elevated temperatures are reported. A numerical modelling study using fire dynamics simulator (FDS) software is then described in which the temperature development was successfully replicated.