{"title":"Sensitivity of a Micro-scale Pump Flow Rate to Actuation Frequency Change","authors":"Gamal Abo Elyamin, Khalid, Abdalrahman","doi":"10.21608/fuje.2024.344039","DOIUrl":null,"url":null,"abstract":"A three-dimensional computational fluid dynamics simulation for a micro-scale pump has been performed to investigate the sensitivity of the flow rate to frequency change during pump and supply phases. Applying dynamic mesh under different diaphragm actuation frequencies ( 8, 50, 100, 200, and 500 Hz ) and sinusoidal oscillation amplitude of 6.0 µm the results showed that at frequency f ≥ 100 Hz the flow separation has been formed in the diffuser direction for both supply and pump phases. At low frequency f ≤ 50 Hz there is no flow separation in the diffuser or the nozzle direction. The large recirculation zone is created at the dif-fuser bottom wall side. The flow separation was found to be frequency and direction dependent for the micro-diffuser half angle of 5o . The net flow rate increased linearly with the frequency while the net flow per cycle was less sensitive to the change of the frequency.","PeriodicalId":267155,"journal":{"name":"Fayoum University Journal of Engineering","volume":"206 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fayoum University Journal of Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/fuje.2024.344039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A three-dimensional computational fluid dynamics simulation for a micro-scale pump has been performed to investigate the sensitivity of the flow rate to frequency change during pump and supply phases. Applying dynamic mesh under different diaphragm actuation frequencies ( 8, 50, 100, 200, and 500 Hz ) and sinusoidal oscillation amplitude of 6.0 µm the results showed that at frequency f ≥ 100 Hz the flow separation has been formed in the diffuser direction for both supply and pump phases. At low frequency f ≤ 50 Hz there is no flow separation in the diffuser or the nozzle direction. The large recirculation zone is created at the dif-fuser bottom wall side. The flow separation was found to be frequency and direction dependent for the micro-diffuser half angle of 5o . The net flow rate increased linearly with the frequency while the net flow per cycle was less sensitive to the change of the frequency.