降低頭頸部癌病人在放射治療中擺位誤差

何聖佑 何聖佑, 謝禮存 Sheng-Yow Ho, 陳佳群 陳佳群, 李淞維 Chia-Chun Chen, 楊淑琴 楊淑琴
{"title":"降低頭頸部癌病人在放射治療中擺位誤差","authors":"何聖佑 何聖佑, 謝禮存 Sheng-Yow Ho, 陳佳群 陳佳群, 李淞維 Chia-Chun Chen, 楊淑琴 楊淑琴","doi":"10.53106/199457952024031802008","DOIUrl":null,"url":null,"abstract":"\n \"目的:運用品管圈手法降低頭頸部癌病人在放射治療之擺位誤差。材料與方法:影響擺位誤差要素分為:身體僵硬或病因性原因無法配合、病人太緊張而導致定位誤差、定位記號線不見了,和不明原因無法與定位時的位置一致,根據三現原則和真因驗證,擬定4個對策群組共10項改進對策。結果:對策實施後X、Y 和 Z 三軸平移擺位誤差平均值和標準差,分別1.67±0.93mm降至1.49±0.58mm(p =0.141) 、1.43±0.66mm降至1.08±0.45mm (p <0.001)和4.05±1.8mm降至1.16±0.55mm (p <0.001);3D向量方向從5.00±1.67mm 降至2.54±0.65mm (p <0.001)。Y軸(roll)旋轉方向從0.76±0.37°³降至0.51±0.24°(p <0.001),而其在3D向量方向>3mm由90%,降低至48%、>5mm則由43%降低至0。結論:有顯著的降低擺位誤差,未來持續提升治療品質與成效。\n Purpose: To reduce setup errors in the treatment of head and neck cancer patients during radiotherapy by applying quality control circle techniques. Materials and Methods: The following factors contributed to setup errors: bodily stiffness or medical conditions preventing patient movement, patient anxiety leading to localization errors, the disappearance of localization markers, and discrepancies between the positioning and reference locations for unknown reasons. Based on the principles of the Three occurrence and verifying true causes, 4 groups consisting of a total of 10 improvement strategies groups were created. Results: Following the implementation of these strategies, the means and standard deviations of setup errors in the X, Y, and Z axes improved from 1.67 ± 0.93 mm to 1.49 ± 0.58 mm (p =0.141), from 1.43 ± 0.66 mm to 1.08 ± 0.45mm (p < 0.001), and from 4.05 ± 1.8 mm to 1.16 ± 0.55 mm (p < 0.001), respectively. Additionally, 3D vector directional setup errors decreased from 5.00 ± 1.67 mm to 2.54 ± 0.65 mm (p < 0.001), and the Y-axis (roll) rotation error decreased from 0.76 ± 0.37° to 0.51 ± 0.24° (p < 0.001). For 3D vector directional errors >3 mm, errors decreased from 90% to 48%; for vector directional errors >5 mm, errors decreased from 43% to 0%. Conclusion: Setup errors were substantially reduced by the adopted strategies.\n \n","PeriodicalId":260200,"journal":{"name":"醫療品質雜誌","volume":"104 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"醫療品質雜誌","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53106/199457952024031802008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

"目的:運用品管圈手法降低頭頸部癌病人在放射治療之擺位誤差。材料與方法:影響擺位誤差要素分為:身體僵硬或病因性原因無法配合、病人太緊張而導致定位誤差、定位記號線不見了,和不明原因無法與定位時的位置一致,根據三現原則和真因驗證,擬定4個對策群組共10項改進對策。結果:對策實施後X、Y 和 Z 三軸平移擺位誤差平均值和標準差,分別1.67±0.93mm降至1.49±0.58mm(p =0.141) 、1.43±0.66mm降至1.08±0.45mm (p <0.001)和4.05±1.8mm降至1.16±0.55mm (p <0.001);3D向量方向從5.00±1.67mm 降至2.54±0.65mm (p <0.001)。Y軸(roll)旋轉方向從0.76±0.37°³降至0.51±0.24°(p <0.001),而其在3D向量方向>3mm由90%,降低至48%、>5mm則由43%降低至0。結論:有顯著的降低擺位誤差,未來持續提升治療品質與成效。  Purpose: To reduce setup errors in the treatment of head and neck cancer patients during radiotherapy by applying quality control circle techniques. Materials and Methods: The following factors contributed to setup errors: bodily stiffness or medical conditions preventing patient movement, patient anxiety leading to localization errors, the disappearance of localization markers, and discrepancies between the positioning and reference locations for unknown reasons. Based on the principles of the Three occurrence and verifying true causes, 4 groups consisting of a total of 10 improvement strategies groups were created. Results: Following the implementation of these strategies, the means and standard deviations of setup errors in the X, Y, and Z axes improved from 1.67 ± 0.93 mm to 1.49 ± 0.58 mm (p =0.141), from 1.43 ± 0.66 mm to 1.08 ± 0.45mm (p < 0.001), and from 4.05 ± 1.8 mm to 1.16 ± 0.55 mm (p < 0.001), respectively. Additionally, 3D vector directional setup errors decreased from 5.00 ± 1.67 mm to 2.54 ± 0.65 mm (p < 0.001), and the Y-axis (roll) rotation error decreased from 0.76 ± 0.37° to 0.51 ± 0.24° (p < 0.001). For 3D vector directional errors >3 mm, errors decreased from 90% to 48%; for vector directional errors >5 mm, errors decreased from 43% to 0%. Conclusion: Setup errors were substantially reduced by the adopted strategies.  
降低頭頸部癌病人在放射治療中擺位誤差
"目的:運用品管圈手法降低頭頸部癌病人在放射治療之擺位誤差。材料與方法:影響擺位誤差要素分為:身體僵硬或病因性原因無法配合、病人太緊張而導致定位誤差、定位記號線不見了,和不明原因無法與定位時的位置一致,根據三現原則和真因驗證,擬定4個對策群組共10項改進對策。結果:對策實施後x、y 和 z 三軸平移擺位誤差平均值和標準差,分別為1.67±0.93mm 降 1.49±0.58mm(p =0.141) 、 1.43±0.66mm 降 1.08±0.45mm (p 3mm由90%,降低至48%、>5mm則由43%降低至0。結論:有顯著的降低擺位誤差,未來持續提升治療品質與成效。 Purpose:通过应用质量控制圈技术,减少头颈部肿瘤患者放疗过程中的设置误差。材料与方法:导致设置错误的因素包括:患者身体僵硬或医疗条件阻碍患者移动、患者焦虑导致定位错误、定位标记消失以及定位与参考位置之间存在不明原因的差异。根据 "三个发生 "和核实真实原因的原则,创建了 4 组共 10 个改进策略小组。结果:实施这些策略后,X、Y 和 Z 轴的设置误差的平均值和标准偏差分别从 1.67 ± 0.93 毫米改善到 1.49 ± 0.58 毫米(p =0.141),从 1.43 ± 0.66 毫米改善到 1.08 ± 0.45 毫米(p < 0.001),从 4.05 ± 1.8 毫米改善到 1.16 ± 0.55 毫米(p < 0.001)。此外,三维矢量方向设置误差从 5.00 ± 1.67 毫米降至 2.54 ± 0.65 毫米(p < 0.001),Y 轴(滚动)旋转误差从 0.76 ± 0.37° 降至 0.51 ± 0.24°(p < 0.001)。三维矢量方向误差大于 3 毫米时,误差率从 90% 降至 48%;矢量方向误差大于 5 毫米时,误差率从 43% 降至 0%。结论:所采用的策略大大减少了设置误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信