Do serial troponins predict the need for cardiac evaluation in trauma patients after ground-level fall?

Alyssa R Bellini, James T. Ross, Madelyn Larson, Skyler Pearson, Anamaria J. Robles, Rachael A. Callcut
{"title":"Do serial troponins predict the need for cardiac evaluation in trauma patients after ground-level fall?","authors":"Alyssa R Bellini, James T. Ross, Madelyn Larson, Skyler Pearson, Anamaria J. Robles, Rachael A. Callcut","doi":"10.1136/tsaco-2023-001328","DOIUrl":null,"url":null,"abstract":"Troponin T levels are routinely checked in trauma patients after experiencing a ground-level fall to identify potential cardiac causes of syncope. An elevated initial troponin prompts serial testing until the level peaks. However, the high sensitivity of the test may lead to repeat testing that is of little clinical value. Here, we examine the role of serial troponins in predicting the need for further cardiac workup in trauma patients after sustaining a fall.Retrospective review of all adult trauma activations for ground-level fall from January 1, 2021 to December 31, 2021 in patients who were hemodynamically and neurologically normal at presentation. Outcomes evaluated included need for cardiology consult, admission to cardiology service, outpatient cardiology follow-up, cardiology intervention and in-hospital mortality.There were 1555 trauma activations for ground-level fall in the study period. The cohort included 560 patients evaluated for a possible syncopal fall, hemodynamically stable, Glasgow Coma Scale score of 15, and with a troponin drawn at presentation. The initial median troponin was 20 ng/L (13–37). Second troponin values were drawn on 58% (median 33 ng/L (22–52)), with 42% of patients having an increase from first to second test. 29% of patients had a third troponin drawn (median 42 ng/L (26–67)). The initial troponin value was significantly associated with undergoing a subsequent echo (p=0.01), cardiology consult (p<0.01), admission for cardiac evaluation (p<0.01), cardiology follow-up (p<0.01), and in-hospital mortality (p=0.01); the initial troponin was not associated with cardiac intervention (p=0.91). An increase from the first to second troponin was not associated with any of outcomes of interest. Analysis was done with cut-off values of 30 ng/L, 50 ng/L, 70 ng/L, and 90 ng/L; a troponin T threshold of 19 ng/L was significant for cardiology consult (p=0.01) and cardiology follow-up (p=0.04). When the threshold was increased to 50 ng/L, it was also significant for admission for cardiac issue (p<0.01). When the threshold was increased to 90 ng/L, it was significant for the same three outcomes and in-hospital mortality (p=0.04).The initial serum troponin has clinical value in identifying underlying cardiac disease in patients who present after ground-level fall; however, that serial testing is likely of little value. Further, using a cut-off of >50 ng/L as a threshold for further clinical evaluation would improve the utility of the test and likely reduce unnecessary hospital stays and costs for otherwise healthy patients.Level III.","PeriodicalId":517101,"journal":{"name":"Trauma Surgery &amp; Acute Care Open","volume":"46 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trauma Surgery &amp; Acute Care Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/tsaco-2023-001328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Troponin T levels are routinely checked in trauma patients after experiencing a ground-level fall to identify potential cardiac causes of syncope. An elevated initial troponin prompts serial testing until the level peaks. However, the high sensitivity of the test may lead to repeat testing that is of little clinical value. Here, we examine the role of serial troponins in predicting the need for further cardiac workup in trauma patients after sustaining a fall.Retrospective review of all adult trauma activations for ground-level fall from January 1, 2021 to December 31, 2021 in patients who were hemodynamically and neurologically normal at presentation. Outcomes evaluated included need for cardiology consult, admission to cardiology service, outpatient cardiology follow-up, cardiology intervention and in-hospital mortality.There were 1555 trauma activations for ground-level fall in the study period. The cohort included 560 patients evaluated for a possible syncopal fall, hemodynamically stable, Glasgow Coma Scale score of 15, and with a troponin drawn at presentation. The initial median troponin was 20 ng/L (13–37). Second troponin values were drawn on 58% (median 33 ng/L (22–52)), with 42% of patients having an increase from first to second test. 29% of patients had a third troponin drawn (median 42 ng/L (26–67)). The initial troponin value was significantly associated with undergoing a subsequent echo (p=0.01), cardiology consult (p<0.01), admission for cardiac evaluation (p<0.01), cardiology follow-up (p<0.01), and in-hospital mortality (p=0.01); the initial troponin was not associated with cardiac intervention (p=0.91). An increase from the first to second troponin was not associated with any of outcomes of interest. Analysis was done with cut-off values of 30 ng/L, 50 ng/L, 70 ng/L, and 90 ng/L; a troponin T threshold of 19 ng/L was significant for cardiology consult (p=0.01) and cardiology follow-up (p=0.04). When the threshold was increased to 50 ng/L, it was also significant for admission for cardiac issue (p<0.01). When the threshold was increased to 90 ng/L, it was significant for the same three outcomes and in-hospital mortality (p=0.04).The initial serum troponin has clinical value in identifying underlying cardiac disease in patients who present after ground-level fall; however, that serial testing is likely of little value. Further, using a cut-off of >50 ng/L as a threshold for further clinical evaluation would improve the utility of the test and likely reduce unnecessary hospital stays and costs for otherwise healthy patients.Level III.
连续肌钙蛋白能否预测地面坠落后的创伤患者是否需要进行心脏评估?
创伤患者在经历地面高空坠落后,需要常规检测肌钙蛋白 T 水平,以确定晕厥的潜在心脏原因。初始肌钙蛋白升高会导致连续检测,直到水平达到峰值。然而,该检测的高灵敏度可能会导致重复检测,而重复检测的临床价值不大。在此,我们研究了连续肌钙蛋白在预测创伤患者摔倒后是否需要进一步心脏检查中的作用。回顾性研究了 2021 年 1 月 1 日至 2021 年 12 月 31 日期间因地面摔倒而启动的所有成人创伤患者,这些患者在就诊时血液动力学和神经系统均正常。评估结果包括是否需要心脏科会诊、心脏科入院、心脏科门诊随访、心脏科干预和院内死亡率。在研究期间,共有 1555 例因地面摔倒而启动的创伤急救,其中包括 560 例因可能发生晕厥摔倒而接受评估的患者,这些患者血流动力学稳定,格拉斯哥昏迷量表评分为 15 分,并在就诊时抽取了肌钙蛋白。最初的肌钙蛋白中位数为 20 纳克/升(13-37)。58%的患者进行了第二次肌钙蛋白检测(中位数为 33 纳克/升(22-52)),其中 42% 的患者从第一次检测到第二次检测的结果均有所上升。29%的患者进行了第三次肌钙蛋白检测(中位数为 42 纳克/升(26-67))。最初的肌钙蛋白值与随后的回波检查(p=0.01)、心脏病咨询(p50 纳克/升作为进一步临床评估的阈值)显著相关,这将提高该检查的实用性,并可能减少原本健康的患者不必要的住院时间和费用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信