Radon Concentrations in the Environments of Some Primary Schools in Khidir City, Al-Muthanna Province, Iraq

Ahmed A. Sharrad, A. Farhood, Russil S. Muhammed
{"title":"Radon Concentrations in the Environments of Some Primary Schools in Khidir City, Al-Muthanna Province, Iraq","authors":"Ahmed A. Sharrad, A. Farhood, Russil S. Muhammed","doi":"10.9734/ajr2p/2024/v8i1157","DOIUrl":null,"url":null,"abstract":"Indoor radon concentrations in 13 primary schools were conducted in Khidir City, Muthanna Province, Iraq, using LR-115 solid-state nuclear track detector type II. The study aims to estimate indoor radon levels in the internal environment of the classrooms for three months (from 1st September to 30th November 2023). Radon concentrations were varied from (0.1 Bq/m3) to (14.13 Bq/m3), with a mean value of (5.61 Bq/m3). The investigated levels were lower than the permissible limits referenced by UNSCEAR and WHO. Moreover, the annual effective dose (AED) has been calculated due to inhalation, which varied from the value of (0.029352 mSv/yr) to the value of (0.081145 mSv/yr), with a mean value of (0.016205 mSv/yr). AED values obtained were found to be lower than the allowed value of (0.1 mSv/yr) reported by UNSCEAR and much lower than the permissible limit (1 mSv/yr) proposed by WHO. However, the results obtained indicate that the indoor radon concentrations were significantly affected by the floor level of the classroom (negatively correlated) and the school building age (positively correlated). Consequently, all results have revealed that the radon concentrations and the associated inhalation radon dose does not pose any kind of health hazard to the occupational stuff and students.","PeriodicalId":8529,"journal":{"name":"Asian Journal of Research and Reviews in Physics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Research and Reviews in Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/ajr2p/2024/v8i1157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Indoor radon concentrations in 13 primary schools were conducted in Khidir City, Muthanna Province, Iraq, using LR-115 solid-state nuclear track detector type II. The study aims to estimate indoor radon levels in the internal environment of the classrooms for three months (from 1st September to 30th November 2023). Radon concentrations were varied from (0.1 Bq/m3) to (14.13 Bq/m3), with a mean value of (5.61 Bq/m3). The investigated levels were lower than the permissible limits referenced by UNSCEAR and WHO. Moreover, the annual effective dose (AED) has been calculated due to inhalation, which varied from the value of (0.029352 mSv/yr) to the value of (0.081145 mSv/yr), with a mean value of (0.016205 mSv/yr). AED values obtained were found to be lower than the allowed value of (0.1 mSv/yr) reported by UNSCEAR and much lower than the permissible limit (1 mSv/yr) proposed by WHO. However, the results obtained indicate that the indoor radon concentrations were significantly affected by the floor level of the classroom (negatively correlated) and the school building age (positively correlated). Consequently, all results have revealed that the radon concentrations and the associated inhalation radon dose does not pose any kind of health hazard to the occupational stuff and students.
伊拉克穆萨纳省希迪尔市部分小学环境中的氡浓度
使用 LR-115 固态核轨道探测器 II 型对伊拉克穆萨纳省希迪尔市 13 所小学的室内氡浓度进行了研究。研究旨在估算教室内部环境中三个月(2023 年 9 月 1 日至 11 月 30 日)的室内氡浓度。氡浓度从(0.1 Bq/m3)到(14.13 Bq/m3)不等,平均值为(5.61 Bq/m3)。所调查的氡浓度水平低于联合国辐射防护委员会和世界卫生组织规定的允许限值。此外,还计算了因吸入而产生的年有效剂量(AED),其数值从(0.029352 mSv/yr)到(0.081145 mSv/yr)不等,平均值为(0.016205 mSv/yr)。所获得的 AED 值低于联合国辐射影响问题科学委员会报告的允许值(0.1 mSv/yr),也远低于世界卫生组织提出的允许限值(1 mSv/yr)。然而,研究结果表明,室内氡浓度受到教室楼层(负相关)和校舍年龄(正相关)的显著影响。因此,所有結果均顯示,氡氣濃度和相關的吸入氡氣劑量不會對職業人員和學生的健康構成任何危害。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信