M. Calvino, Isabel Sánchez-Cuadrado, Elena Muñoz, Javier Gavilán, Luis Lassaletta
{"title":"Successful hearing preservation and improved subjective sound quality with the flexible 28-mm electrode array","authors":"M. Calvino, Isabel Sánchez-Cuadrado, Elena Muñoz, Javier Gavilán, Luis Lassaletta","doi":"10.3389/fauot.2024.1357306","DOIUrl":null,"url":null,"abstract":"Flexible electrode arrays have shown to be an effective solution to ensure atraumatic insertion. However, flexible full-length electrodes are not suited for patients with smaller cochleae. Therefore, this study aimed to evaluate short-term and medium-term hearing preservation (HP) in patients with low-frequency residual hearing (LFRH) who were implanted with a flexible 28-mm electrode array and who did not meet the indication criteria for electric-acoustic stimulation (EAS).HP was determined based on the pure-tone audiogram of the implanted ear. A bisyllable sentence test was used to assess speech perception in quiet and in noise. The hearing implant sound quality index (HISQUI19) evaluated self-reported hearing quality. The tests were conducted pre- and post-operatively, at first fitting, and at 1, 3, 6, and 12 months after first fitting.At 12 months post first fitting, 2 patients had complete HP; 4 patients had partial HP. Speech perception scores improved in all patients of the study. The mean scores on the bisyllable sentence test in noise significantly increased from 30% pre-operatively to 62% 6 months post first-fitting and to 68% 12 months post first-fitting. The mean score of the HISQUI19 improved from 40.56 (poor) pre-operatively to 72.56 (moderate) 1 month post first-fitting and to 90.29 (good) 12 months post first-fitting.The 28-mm flexible electrode array facilitates atraumatic surgery and HP and results in improved speech perception and subjective sound quality scores.","PeriodicalId":483207,"journal":{"name":"Frontiers in Audiology and Otology","volume":"51 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Audiology and Otology","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.3389/fauot.2024.1357306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Flexible electrode arrays have shown to be an effective solution to ensure atraumatic insertion. However, flexible full-length electrodes are not suited for patients with smaller cochleae. Therefore, this study aimed to evaluate short-term and medium-term hearing preservation (HP) in patients with low-frequency residual hearing (LFRH) who were implanted with a flexible 28-mm electrode array and who did not meet the indication criteria for electric-acoustic stimulation (EAS).HP was determined based on the pure-tone audiogram of the implanted ear. A bisyllable sentence test was used to assess speech perception in quiet and in noise. The hearing implant sound quality index (HISQUI19) evaluated self-reported hearing quality. The tests were conducted pre- and post-operatively, at first fitting, and at 1, 3, 6, and 12 months after first fitting.At 12 months post first fitting, 2 patients had complete HP; 4 patients had partial HP. Speech perception scores improved in all patients of the study. The mean scores on the bisyllable sentence test in noise significantly increased from 30% pre-operatively to 62% 6 months post first-fitting and to 68% 12 months post first-fitting. The mean score of the HISQUI19 improved from 40.56 (poor) pre-operatively to 72.56 (moderate) 1 month post first-fitting and to 90.29 (good) 12 months post first-fitting.The 28-mm flexible electrode array facilitates atraumatic surgery and HP and results in improved speech perception and subjective sound quality scores.