Successful hearing preservation and improved subjective sound quality with the flexible 28-mm electrode array

M. Calvino, Isabel Sánchez-Cuadrado, Elena Muñoz, Javier Gavilán, Luis Lassaletta
{"title":"Successful hearing preservation and improved subjective sound quality with the flexible 28-mm electrode array","authors":"M. Calvino, Isabel Sánchez-Cuadrado, Elena Muñoz, Javier Gavilán, Luis Lassaletta","doi":"10.3389/fauot.2024.1357306","DOIUrl":null,"url":null,"abstract":"Flexible electrode arrays have shown to be an effective solution to ensure atraumatic insertion. However, flexible full-length electrodes are not suited for patients with smaller cochleae. Therefore, this study aimed to evaluate short-term and medium-term hearing preservation (HP) in patients with low-frequency residual hearing (LFRH) who were implanted with a flexible 28-mm electrode array and who did not meet the indication criteria for electric-acoustic stimulation (EAS).HP was determined based on the pure-tone audiogram of the implanted ear. A bisyllable sentence test was used to assess speech perception in quiet and in noise. The hearing implant sound quality index (HISQUI19) evaluated self-reported hearing quality. The tests were conducted pre- and post-operatively, at first fitting, and at 1, 3, 6, and 12 months after first fitting.At 12 months post first fitting, 2 patients had complete HP; 4 patients had partial HP. Speech perception scores improved in all patients of the study. The mean scores on the bisyllable sentence test in noise significantly increased from 30% pre-operatively to 62% 6 months post first-fitting and to 68% 12 months post first-fitting. The mean score of the HISQUI19 improved from 40.56 (poor) pre-operatively to 72.56 (moderate) 1 month post first-fitting and to 90.29 (good) 12 months post first-fitting.The 28-mm flexible electrode array facilitates atraumatic surgery and HP and results in improved speech perception and subjective sound quality scores.","PeriodicalId":483207,"journal":{"name":"Frontiers in Audiology and Otology","volume":"51 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Audiology and Otology","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.3389/fauot.2024.1357306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Flexible electrode arrays have shown to be an effective solution to ensure atraumatic insertion. However, flexible full-length electrodes are not suited for patients with smaller cochleae. Therefore, this study aimed to evaluate short-term and medium-term hearing preservation (HP) in patients with low-frequency residual hearing (LFRH) who were implanted with a flexible 28-mm electrode array and who did not meet the indication criteria for electric-acoustic stimulation (EAS).HP was determined based on the pure-tone audiogram of the implanted ear. A bisyllable sentence test was used to assess speech perception in quiet and in noise. The hearing implant sound quality index (HISQUI19) evaluated self-reported hearing quality. The tests were conducted pre- and post-operatively, at first fitting, and at 1, 3, 6, and 12 months after first fitting.At 12 months post first fitting, 2 patients had complete HP; 4 patients had partial HP. Speech perception scores improved in all patients of the study. The mean scores on the bisyllable sentence test in noise significantly increased from 30% pre-operatively to 62% 6 months post first-fitting and to 68% 12 months post first-fitting. The mean score of the HISQUI19 improved from 40.56 (poor) pre-operatively to 72.56 (moderate) 1 month post first-fitting and to 90.29 (good) 12 months post first-fitting.The 28-mm flexible electrode array facilitates atraumatic surgery and HP and results in improved speech perception and subjective sound quality scores.
使用灵活的 28 毫米电极阵列成功保护听力并改善主观音质
柔性电极阵列已被证明是确保无创插入的有效解决方案。然而,柔性全长电极并不适合耳蜗较小的患者。因此,本研究旨在评估植入 28 毫米柔性电极阵列且不符合电声刺激(EAS)适应症标准的低频残余听力(LFRH)患者的短期和中期听力保存(HP)情况。根据植入耳的纯音听力图确定听力质量。双音节句子测试用于评估安静和噪音环境下的言语感知。听力植入音质指数(HISQUI19)对自我报告的听力质量进行评估。测试分别在术前、术后、首次验配以及首次验配后 1、3、6 和 12 个月进行。研究中所有患者的言语感知评分都有所提高。噪声双音节句测试的平均得分从术前的 30% 显著提高到首次配戴后 6 个月的 62%,首次配戴后 12 个月的 68%。HISQUI19 的平均得分从术前的 40.56 分(差)提高到首次配戴后 1 个月的 72.56 分(中)和首次配戴后 12 个月的 90.29 分(好)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信