Mechanical Behavior of Polymer Braided Stent at Rapid Radial Loading

Xue Hu, Chen Zhang, Bin Wang, Jin Bo Liu, Jie Cheng, Gu Tian Zhao, Zhong Hua Ni, Jue Kuan Yang
{"title":"Mechanical Behavior of Polymer Braided Stent at Rapid Radial Loading","authors":"Xue Hu, Chen Zhang, Bin Wang, Jin Bo Liu, Jie Cheng, Gu Tian Zhao, Zhong Hua Ni, Jue Kuan Yang","doi":"10.4028/p-0xc6xg","DOIUrl":null,"url":null,"abstract":"Stent implantation is the mainstream treatment for high-incidence vascular diseases. The stent is implanted into the blocked vessel with minimal trauma to restore blood flow. Polymer braided stents with superior biocompatibility and flexibility have broad application prospects in stent implantation. An ideal polymer stent should have suitable radial supporting capacity to withstand the cyclic radial load from vessels. Especially in the case of accelerated vasoconstriction caused by emotional excitement, drinking or fever, etc. However, there are currently limited studies on the mechanical properties of stent at rapid radial loading. In this work, the radial supporting capacity and fatigue properties of polymer stent at rapid loading rate were investigated by experiment and simulation. With the increase of radial loading rate, the stent has different deformation tendency and fatigue resistance. This study is helpful to study the structural changes of the polymer braided stent at different loading rates, and provide ideas for the evaluation and the optimization of the polymer braided stent.","PeriodicalId":17714,"journal":{"name":"Key Engineering Materials","volume":" 28","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Key Engineering Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4028/p-0xc6xg","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Stent implantation is the mainstream treatment for high-incidence vascular diseases. The stent is implanted into the blocked vessel with minimal trauma to restore blood flow. Polymer braided stents with superior biocompatibility and flexibility have broad application prospects in stent implantation. An ideal polymer stent should have suitable radial supporting capacity to withstand the cyclic radial load from vessels. Especially in the case of accelerated vasoconstriction caused by emotional excitement, drinking or fever, etc. However, there are currently limited studies on the mechanical properties of stent at rapid radial loading. In this work, the radial supporting capacity and fatigue properties of polymer stent at rapid loading rate were investigated by experiment and simulation. With the increase of radial loading rate, the stent has different deformation tendency and fatigue resistance. This study is helpful to study the structural changes of the polymer braided stent at different loading rates, and provide ideas for the evaluation and the optimization of the polymer braided stent.
快速径向加载时聚合物编织支架的机械行为
支架植入术是治疗高发血管疾病的主流方法。将支架植入堵塞的血管中,以最小的创伤恢复血流。具有良好生物相容性和柔韧性的聚合物编织支架在支架植入中具有广阔的应用前景。理想的聚合物支架应具有适当的径向支撑能力,以承受来自血管的周期性径向负荷。尤其是在情绪激动、饮酒或发烧等导致血管加速收缩的情况下。然而,目前对支架在快速径向负荷下的机械性能的研究还很有限。本文通过实验和模拟研究了聚合物支架在快速加载速率下的径向支撑能力和疲劳特性。随着径向加载速率的增加,支架具有不同的变形趋势和抗疲劳性能。该研究有助于研究聚合物编织支架在不同加载速率下的结构变化,为聚合物编织支架的评估和优化提供思路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.00
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信