Gender and Body Mass Index Difference in Aerobic Capacity: A Study in Moroccan High School Students.

Q3 Medicine
Hassan Benchelha, Miloud Chakit, Mustapha Mouilly, Karim Nadir, Mohamed Barkaoui, Abdelhak Moustaine, Abdelkarim Elkhatir, Ahmed O T Ahami, Leila Bikjdaouene
{"title":"Gender and Body Mass Index Difference in Aerobic Capacity: A Study in Moroccan High School Students.","authors":"Hassan Benchelha, Miloud Chakit, Mustapha Mouilly, Karim Nadir, Mohamed Barkaoui, Abdelhak Moustaine, Abdelkarim Elkhatir, Ahmed O T Ahami, Leila Bikjdaouene","doi":"10.5935/0946-5448.20230030","DOIUrl":null,"url":null,"abstract":"<p><p>Different tests are used to evaluate the aerobic capacity of a person. This study aims to investigate the gender and Body Mass Index (BMI) difference in aerobic capacity measured by using shuttle and Spartacus test. The study was conducted on 230 high school students (135 girls and 95 boys) followed their study in public establishment in kenitra city (Morocco). All participants were classified according to their gender (male vs. female) and their BMI (normal weight vs. overweight-obese) and performed the both test of shuttle and Spartacus. Running speed at the last completed stage, run time, maximum heart rate (max HR) max HR and perceived exertion were measured and analyzed. For each test, VO2max was estimated by using the proposed equation. There was significant BMI difference in the measured parameters (p<0.001). Difference in VO2max between male and female remained significant with high-speed level in boys. A significant difference between males and females (p < 0.001) was observed in shuttle test. Participants with normal weight or physical activity had good aerobic capacity. Compared to the Shuttle test, the Spartacus provides a 11.5% higher final speed (11.2 vs. 9.7km/h) and a total test time 2.3 times longer (11.3vs. 4.9 min) (p < 0.001). Our study underlines the interest of the Spartacus test and is preliminary. Indeed, these results must now be replicated in a larger sample of obese adolescents.</p>","PeriodicalId":39842,"journal":{"name":"International Tinnitus Journal","volume":"27 2","pages":"198-202"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Tinnitus Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5935/0946-5448.20230030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Different tests are used to evaluate the aerobic capacity of a person. This study aims to investigate the gender and Body Mass Index (BMI) difference in aerobic capacity measured by using shuttle and Spartacus test. The study was conducted on 230 high school students (135 girls and 95 boys) followed their study in public establishment in kenitra city (Morocco). All participants were classified according to their gender (male vs. female) and their BMI (normal weight vs. overweight-obese) and performed the both test of shuttle and Spartacus. Running speed at the last completed stage, run time, maximum heart rate (max HR) max HR and perceived exertion were measured and analyzed. For each test, VO2max was estimated by using the proposed equation. There was significant BMI difference in the measured parameters (p<0.001). Difference in VO2max between male and female remained significant with high-speed level in boys. A significant difference between males and females (p < 0.001) was observed in shuttle test. Participants with normal weight or physical activity had good aerobic capacity. Compared to the Shuttle test, the Spartacus provides a 11.5% higher final speed (11.2 vs. 9.7km/h) and a total test time 2.3 times longer (11.3vs. 4.9 min) (p < 0.001). Our study underlines the interest of the Spartacus test and is preliminary. Indeed, these results must now be replicated in a larger sample of obese adolescents.

有氧运动能力的性别和体重指数差异:摩洛哥高中生研究
不同的测试用于评估一个人的有氧能力。本研究旨在调查通过穿梭和斯巴达克斯测试测量的有氧能力的性别和身体质量指数(BMI)差异。研究对象是摩洛哥凯尼特拉市公立学校的 230 名高中生(135 名女生和 95 名男生)。所有参与者都根据性别(男性与女性)和体重指数(正常体重与超重-肥胖)进行了分类,并同时进行了穿梭和斯巴达克斯测试。测量并分析了最后完成阶段的跑步速度、跑步时间、最大心率(max HR)、最大心率和感觉消耗量。对于每项测试,都使用拟议方程估算了最大氧饱和度。在测量的参数中,体重指数差异明显(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Tinnitus Journal
International Tinnitus Journal Medicine-Otorhinolaryngology
CiteScore
0.70
自引率
0.00%
发文量
11
期刊介绍: The International Tinnitus Journal is the first peer review journal to provide a forum for exchange of information of on-going basic and clinical science efforts for understanding tinnitus and its application to patient diagnosis and treatment. Subject areas to be covered range from fundamental theory to clinical applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信