The influence of different cement spaces on the marginal gap of lithium disilicate crowns constructed by two scanner and milling unit combinations

IF 1.9 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
J Dudley, J Xu
{"title":"The influence of different cement spaces on the marginal gap of lithium disilicate crowns constructed by two scanner and milling unit combinations","authors":"J Dudley,&nbsp;J Xu","doi":"10.1111/adj.13014","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>This study compared the marginal gaps of CAD/CAM lithium disilicate (LDS) crowns constructed using a contemporary and older scanner/milling unit combination at three different cement spaces.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Twenty-four undergraduate students prepared a Columbia model lower left first molar for an LDS crown in a simulated environment. From each crown preparation, one LDS crown was constructed using an E4D scanner/E4D milling unit (E4DS/E4DM) and TRIOS 3 scanner/Sirona inLab MC X5 milling unit (TRIO/MCX5) at cement space settings of 50, 100 and 200 μm. Each LDS crown was positioned onto the original crown preparation, and then a stereomicroscope was used to make three vertical marginal gap measurements at four locations (mid-buccal, mid-lingual, mid-mesial and mid-distal). The mean marginal gap (MMG) was calculated for each crown and each individual tooth surface.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The MMGs of CAD/CAM LDS crowns constructed by TRIO/MCX5 were 72.31 at 50, 63.73 at 100 μm and 46.23 μm at 200 μm, which were smaller than E4DS/E4DM at each cement space.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Increasing the cement space decreased the MMG in both scanner/milling unit combinations. The smallest MMG was found using the newer scanner/milling unit at the 200 μm cement space. © 2024 Australian Dental Association.</p>\n </section>\n </div>","PeriodicalId":8593,"journal":{"name":"Australian dental journal","volume":"69 3","pages":"189-196"},"PeriodicalIF":1.9000,"publicationDate":"2024-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/adj.13014","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australian dental journal","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/adj.13014","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background

This study compared the marginal gaps of CAD/CAM lithium disilicate (LDS) crowns constructed using a contemporary and older scanner/milling unit combination at three different cement spaces.

Methods

Twenty-four undergraduate students prepared a Columbia model lower left first molar for an LDS crown in a simulated environment. From each crown preparation, one LDS crown was constructed using an E4D scanner/E4D milling unit (E4DS/E4DM) and TRIOS 3 scanner/Sirona inLab MC X5 milling unit (TRIO/MCX5) at cement space settings of 50, 100 and 200 μm. Each LDS crown was positioned onto the original crown preparation, and then a stereomicroscope was used to make three vertical marginal gap measurements at four locations (mid-buccal, mid-lingual, mid-mesial and mid-distal). The mean marginal gap (MMG) was calculated for each crown and each individual tooth surface.

Results

The MMGs of CAD/CAM LDS crowns constructed by TRIO/MCX5 were 72.31 at 50, 63.73 at 100 μm and 46.23 μm at 200 μm, which were smaller than E4DS/E4DM at each cement space.

Conclusions

Increasing the cement space decreased the MMG in both scanner/milling unit combinations. The smallest MMG was found using the newer scanner/milling unit at the 200 μm cement space. © 2024 Australian Dental Association.

Abstract Image

使用两种扫描仪和铣削装置组合制作的二硅酸锂冠,不同的粘接剂空间对边缘间隙的影响。
背景:本研究比较了在三种不同的粘接间隙下使用当代和老式扫描仪/铣削装置组合制作的CAD/CAM二硅酸锂(LDS)牙冠的边缘间隙:二十四名本科生在模拟环境中为哥伦比亚模型左下第一磨牙制作 LDS 牙冠。使用 E4D 扫描仪/E4D 铣削装置(E4DS/E4DM)和 TRIOS 3 扫描仪/Sirona inLab MC X5 铣削装置(TRIO/MCX5),在 50、100 和 200 μm 的骨水泥间隙设置下,为每个牙冠制备一个 LDS 牙冠。将每个 LDS 牙冠放置在原始牙冠制备体上,然后使用体视显微镜在四个位置(颊中、舌中、趾中和趾间)进行三次垂直边缘间隙测量。计算出每个牙冠和每个牙面的平均边缘间隙(MMG):TRIO/MCX5制作的CAD/CAM LDS牙冠在50μm、100μm和200μm时的平均边缘间隙分别为72.31μm、63.73μm和46.23μm:结论:在两种扫描仪/铣削单元组合中,增大水门汀间隙都会降低MMG。在 200 μm 骨水泥间隙时,使用较新的扫描仪/铣削装置发现的 MMG 最小。© 2024 澳大利亚牙科协会。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Australian dental journal
Australian dental journal 医学-牙科与口腔外科
CiteScore
4.20
自引率
4.80%
发文量
50
审稿时长
6-12 weeks
期刊介绍: The Australian Dental Journal provides a forum for the exchange of information about new and significant research in dentistry, promoting the discipline of dentistry in Australia and throughout the world. It comprises peer-reviewed research articles as its core material, supplemented by reviews, theoretical articles, special features and commentaries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信