Víctor Rendón, M. Sánchez-Juny, Soledad Estrella, M. Sanz-Ramos, Percy Rucano, Alan Huarca Pulcha
{"title":"Discharge Coefficients of Standard Spillways at High Altitudes","authors":"Víctor Rendón, M. Sánchez-Juny, Soledad Estrella, M. Sanz-Ramos, Percy Rucano, Alan Huarca Pulcha","doi":"10.3390/designs8020022","DOIUrl":null,"url":null,"abstract":"This paper presents an experimental campaign conducted next to the Condoroma dam, in Perú, at 4075 m a.s.l. The tests carried out in this paper were conducted in a 21 m long channel located at the toe of Condoroma dam. The setup consisted of a series of standard profile spillways with a vertical upstream face of up to five different dimensionless heights (P/Hd) ranging from 0.5 to 2. The experimental results indicated that, the P/Hd ratio influences the discharge coefficients in Condoroma, and P/Hd ≥ 1 values are recommended for the design of the spillway profile. In addition, for all the P/Hd ratios studied, the discharge coefficients adjusted to the Condoroma altitude were lower than those reported by classical formulations used in conventional spillway designs. Finally, a generalized equation is proposed to estimate the discharge coefficient for standard spillways located in dams at similar elevations above sea level.","PeriodicalId":53150,"journal":{"name":"Designs","volume":"110 46","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Designs","FirstCategoryId":"1094","ListUrlMain":"https://doi.org/10.3390/designs8020022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
This paper presents an experimental campaign conducted next to the Condoroma dam, in Perú, at 4075 m a.s.l. The tests carried out in this paper were conducted in a 21 m long channel located at the toe of Condoroma dam. The setup consisted of a series of standard profile spillways with a vertical upstream face of up to five different dimensionless heights (P/Hd) ranging from 0.5 to 2. The experimental results indicated that, the P/Hd ratio influences the discharge coefficients in Condoroma, and P/Hd ≥ 1 values are recommended for the design of the spillway profile. In addition, for all the P/Hd ratios studied, the discharge coefficients adjusted to the Condoroma altitude were lower than those reported by classical formulations used in conventional spillway designs. Finally, a generalized equation is proposed to estimate the discharge coefficient for standard spillways located in dams at similar elevations above sea level.