Discharge Coefficients of Standard Spillways at High Altitudes

Q2 Engineering
Designs Pub Date : 2024-03-01 DOI:10.3390/designs8020022
Víctor Rendón, M. Sánchez-Juny, Soledad Estrella, M. Sanz-Ramos, Percy Rucano, Alan Huarca Pulcha
{"title":"Discharge Coefficients of Standard Spillways at High Altitudes","authors":"Víctor Rendón, M. Sánchez-Juny, Soledad Estrella, M. Sanz-Ramos, Percy Rucano, Alan Huarca Pulcha","doi":"10.3390/designs8020022","DOIUrl":null,"url":null,"abstract":"This paper presents an experimental campaign conducted next to the Condoroma dam, in Perú, at 4075 m a.s.l. The tests carried out in this paper were conducted in a 21 m long channel located at the toe of Condoroma dam. The setup consisted of a series of standard profile spillways with a vertical upstream face of up to five different dimensionless heights (P/Hd) ranging from 0.5 to 2. The experimental results indicated that, the P/Hd ratio influences the discharge coefficients in Condoroma, and P/Hd ≥ 1 values are recommended for the design of the spillway profile. In addition, for all the P/Hd ratios studied, the discharge coefficients adjusted to the Condoroma altitude were lower than those reported by classical formulations used in conventional spillway designs. Finally, a generalized equation is proposed to estimate the discharge coefficient for standard spillways located in dams at similar elevations above sea level.","PeriodicalId":53150,"journal":{"name":"Designs","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Designs","FirstCategoryId":"1094","ListUrlMain":"https://doi.org/10.3390/designs8020022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents an experimental campaign conducted next to the Condoroma dam, in Perú, at 4075 m a.s.l. The tests carried out in this paper were conducted in a 21 m long channel located at the toe of Condoroma dam. The setup consisted of a series of standard profile spillways with a vertical upstream face of up to five different dimensionless heights (P/Hd) ranging from 0.5 to 2. The experimental results indicated that, the P/Hd ratio influences the discharge coefficients in Condoroma, and P/Hd ≥ 1 values are recommended for the design of the spillway profile. In addition, for all the P/Hd ratios studied, the discharge coefficients adjusted to the Condoroma altitude were lower than those reported by classical formulations used in conventional spillway designs. Finally, a generalized equation is proposed to estimate the discharge coefficient for standard spillways located in dams at similar elevations above sea level.
高海拔地区标准泄洪道的排水系数
本文介绍了在秘鲁海拔 4075 米的 Condoroma 大坝附近进行的实验活动。本文中的测试是在 Condoroma 大坝坝脚的一条 21 米长的水道中进行的。试验装置包括一系列标准剖面溢洪道,其上游垂直面有五种不同的无量纲高度(P/Hd),从 0.5 到 2 不等。 试验结果表明,P/Hd 比值会影响 Condoroma 大坝的泄洪系数,建议在设计溢洪道剖面时将 P/Hd 值≥1。此外,对于所研究的所有 P/Hd 比率,根据 Condoroma 海拔高度调整后的泄流系数均低于传统泄洪道设计中使用的经典公式所报告的泄流系数。最后,我们提出了一个通用方程,用于估算位于类似海拔高度的大坝中的标准溢洪道的泄洪系数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Designs
Designs Engineering-Engineering (miscellaneous)
CiteScore
3.90
自引率
0.00%
发文量
0
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信