Accuracy of rapid blood coagulation testing device FibCare® in a tertiary emergency department

IF 1.5 Q2 MEDICINE, GENERAL & INTERNAL
Yutaka Mihara, Kenta Komoriya, Kei Hagiwara, Yasuhito Hatanaka, Keita Shibahashi, Mayu Hikone, Kazuhiro Sugiyama
{"title":"Accuracy of rapid blood coagulation testing device FibCare® in a tertiary emergency department","authors":"Yutaka Mihara,&nbsp;Kenta Komoriya,&nbsp;Kei Hagiwara,&nbsp;Yasuhito Hatanaka,&nbsp;Keita Shibahashi,&nbsp;Mayu Hikone,&nbsp;Kazuhiro Sugiyama","doi":"10.1002/ams2.934","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Aim</h3>\n \n <p>FibCare<sup>®</sup> is a novel point-of-care testing device enabling prompt evaluation of fibrinogen levels. This study aimed to investigate the accuracy of FibCare<sup>®</sup> at a tertiary emergency department.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Blood specimens obtained at a tertiary emergency medical center between October 1, 2021, and April 30, 2023, were evaluated. The correlation between the fibrinogen levels assessed via FibCare<sup>®</sup> and those via the Clauss method was evaluated using the Spearman's test. The discrepancy between the two measurement methods was assessed according to fibrinogen level and diagnosis.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>A total of 177 specimens from 147 patients were eligible for the analysis. The median age of the patients was 49 years, and 109 (61.6%) were men. The two measurements had statistically significant but moderate correlation (<i>p</i> &lt; 0.001, <i>ρ</i> = 0.76). FibCare<sup>®</sup> missed 14 out of 35 cases from patients with hypofibrinogenemia (fibrinogen ≤150 mg/dL assessed by the Clauss method). The discrepancy between the two measurements was significantly greater in specimens with lower fibrinogen levels and those obtained from patients following trauma.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>FibCare<sup>®</sup>, a novel point-of-care testing device, can be compatible with the Clauss method. However, clinicians should be aware of the risk that FibCare<sup>®</sup> may underestimate fibrinogen reduction, especially in severe cases and trauma cases.</p>\n </section>\n </div>","PeriodicalId":7196,"journal":{"name":"Acute Medicine & Surgery","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10916673/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acute Medicine & Surgery","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ams2.934","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Aim

FibCare® is a novel point-of-care testing device enabling prompt evaluation of fibrinogen levels. This study aimed to investigate the accuracy of FibCare® at a tertiary emergency department.

Methods

Blood specimens obtained at a tertiary emergency medical center between October 1, 2021, and April 30, 2023, were evaluated. The correlation between the fibrinogen levels assessed via FibCare® and those via the Clauss method was evaluated using the Spearman's test. The discrepancy between the two measurement methods was assessed according to fibrinogen level and diagnosis.

Results

A total of 177 specimens from 147 patients were eligible for the analysis. The median age of the patients was 49 years, and 109 (61.6%) were men. The two measurements had statistically significant but moderate correlation (p < 0.001, ρ = 0.76). FibCare® missed 14 out of 35 cases from patients with hypofibrinogenemia (fibrinogen ≤150 mg/dL assessed by the Clauss method). The discrepancy between the two measurements was significantly greater in specimens with lower fibrinogen levels and those obtained from patients following trauma.

Conclusions

FibCare®, a novel point-of-care testing device, can be compatible with the Clauss method. However, clinicians should be aware of the risk that FibCare® may underestimate fibrinogen reduction, especially in severe cases and trauma cases.

Abstract Image

快速血液凝固检测设备 FibCare® 在三级急诊科的准确性。
目的:FibCare® 是一种新型的床旁检测设备,可迅速评估纤维蛋白原水平。本研究旨在调查 FibCare® 在三级急诊科的准确性:评估了 2021 年 10 月 1 日至 2023 年 4 月 30 日期间在一家三级急诊医疗中心采集的血液样本。使用斯皮尔曼检验评估了通过 FibCare® 评估的纤维蛋白原水平与通过克劳斯法评估的纤维蛋白原水平之间的相关性。根据纤维蛋白原水平和诊断结果评估了两种测量方法之间的差异:共有来自 147 名患者的 177 份标本符合分析条件。患者的中位年龄为 49 岁,其中 109 人(61.6%)为男性。这两项测量结果在统计学上有显著的中度相关性(p ρ = 0.76)。在 35 例低纤维蛋白原血症(克劳斯法评估的纤维蛋白原≤150 mg/dL)患者中,FibCare® 漏测了 14 例。在纤维蛋白原水平较低的标本和外伤后患者的标本中,两种测量结果之间的差异明显更大:结论:FibCare® 是一种新型的床旁检测设备,可与克劳斯法兼容。然而,临床医生应注意 FibCare® 可能会低估纤维蛋白原减少的风险,尤其是在严重病例和创伤病例中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acute Medicine & Surgery
Acute Medicine & Surgery MEDICINE, GENERAL & INTERNAL-
自引率
12.50%
发文量
87
审稿时长
53 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信