Hisako Nishimoto, Tadayoshi Kurita, Mikihiro Shimizu, Koji Morita, Yoshiki Nakajima
{"title":"Predicted effect-site concentrations of remimazolam for i-gel insertion: a prospective randomized controlled study.","authors":"Hisako Nishimoto, Tadayoshi Kurita, Mikihiro Shimizu, Koji Morita, Yoshiki Nakajima","doi":"10.1007/s10877-024-01135-4","DOIUrl":null,"url":null,"abstract":"<p><p>This study is the first to report 50% and 95% effect-site concentrations (EC<sub>50</sub> and EC<sub>95</sub>, respectively) of the new short-acting benzodiazepine, remimazolam, for the successful insertion of i-gels with co-administration of fentanyl. Thirty patients (38 ± 5 years old, male/female = 4/26) were randomly assigned into five groups to receive one of five different remimazolam doses (0.1, 0.15, 0.2, 0.25, and 0.3 mg/kg bolus followed by infusion of 1, 1.5, 2, 2.5, and 3 mg/kg/h, respectively, for 10 min), which were designed to maintain a constant effect-site concentration of remimazolam at the time of i-gel insertion. At 6 min after the start of remimazolam infusion, all patients received 2 µg/kg fentanyl. i-gel insertion was attempted at 10 min and the success or failure of insertion were assessed by the patient response. Probit analysis was used to estimate the EC<sub>50</sub> and EC<sub>95</sub> values of remimazolam with 95% confidence intervals (CIs). In the five remimazolam dose groups, two, two, four, five, and six of the six patients in each group had an i-gel successfully inserted. Two patients in the lowest remimazolam dose group were conscious at the time of i-gel insertion and were counted as failures. The EC<sub>50</sub> and EC<sub>95</sub> values of remimazolam were 0.88 (95% CI, 0.65-1.11) and 1.57 (95% CI, 1.09-2.05) µg/ml, respectively. An effect-site concentration of ≥ 1.57 µg/ml was needed to insert an i-gel using remimazolam anesthesia, even with 2 µg/kg fentanyl. Trial registration: The study was registered in Japan Registry of Clinical Trials on 19 April 2021, Code jRCTs041210009.</p>","PeriodicalId":15513,"journal":{"name":"Journal of Clinical Monitoring and Computing","volume":" ","pages":"885-892"},"PeriodicalIF":2.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Monitoring and Computing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10877-024-01135-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/5 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
This study is the first to report 50% and 95% effect-site concentrations (EC50 and EC95, respectively) of the new short-acting benzodiazepine, remimazolam, for the successful insertion of i-gels with co-administration of fentanyl. Thirty patients (38 ± 5 years old, male/female = 4/26) were randomly assigned into five groups to receive one of five different remimazolam doses (0.1, 0.15, 0.2, 0.25, and 0.3 mg/kg bolus followed by infusion of 1, 1.5, 2, 2.5, and 3 mg/kg/h, respectively, for 10 min), which were designed to maintain a constant effect-site concentration of remimazolam at the time of i-gel insertion. At 6 min after the start of remimazolam infusion, all patients received 2 µg/kg fentanyl. i-gel insertion was attempted at 10 min and the success or failure of insertion were assessed by the patient response. Probit analysis was used to estimate the EC50 and EC95 values of remimazolam with 95% confidence intervals (CIs). In the five remimazolam dose groups, two, two, four, five, and six of the six patients in each group had an i-gel successfully inserted. Two patients in the lowest remimazolam dose group were conscious at the time of i-gel insertion and were counted as failures. The EC50 and EC95 values of remimazolam were 0.88 (95% CI, 0.65-1.11) and 1.57 (95% CI, 1.09-2.05) µg/ml, respectively. An effect-site concentration of ≥ 1.57 µg/ml was needed to insert an i-gel using remimazolam anesthesia, even with 2 µg/kg fentanyl. Trial registration: The study was registered in Japan Registry of Clinical Trials on 19 April 2021, Code jRCTs041210009.
期刊介绍:
The Journal of Clinical Monitoring and Computing is a clinical journal publishing papers related to technology in the fields of anaesthesia, intensive care medicine, emergency medicine, and peri-operative medicine.
The journal has links with numerous specialist societies, including editorial board representatives from the European Society for Computing and Technology in Anaesthesia and Intensive Care (ESCTAIC), the Society for Technology in Anesthesia (STA), the Society for Complex Acute Illness (SCAI) and the NAVAt (NAVigating towards your Anaestheisa Targets) group.
The journal publishes original papers, narrative and systematic reviews, technological notes, letters to the editor, editorial or commentary papers, and policy statements or guidelines from national or international societies. The journal encourages debate on published papers and technology, including letters commenting on previous publications or technological concerns. The journal occasionally publishes special issues with technological or clinical themes, or reports and abstracts from scientificmeetings. Special issues proposals should be sent to the Editor-in-Chief. Specific details of types of papers, and the clinical and technological content of papers considered within scope can be found in instructions for authors.