Effect of Geometrical Parameters on the Thermal-Hydraulic Performance of Internal Helically Ribbed Tubes

IF 1.5 4区 工程技术 Q3 ENGINEERING, MECHANICAL
Wentao Ji, Yi Du, Guo-Hui Ou, Pu-Hang Jin, Chuang-Yao Zhao, Ding-Cai Zhang, Wen-Quan Tao
{"title":"Effect of Geometrical Parameters on the Thermal-Hydraulic Performance of Internal Helically Ribbed Tubes","authors":"Wentao Ji, Yi Du, Guo-Hui Ou, Pu-Hang Jin, Chuang-Yao Zhao, Ding-Cai Zhang, Wen-Quan Tao","doi":"10.1615/jenhheattransf.2024051809","DOIUrl":null,"url":null,"abstract":"The flow and heat transfer experiments are conducted in this paper for eleven internally grooved tubes. Refrigerants are boiling or condensing outside the tube. The experimental tubes have the internal helical rib heights of 0.25-0.36 mm, helix angles of 40-60°, rib base thicknesses of 0.40-0.79 mm, rib tip thicknesses of 0.078-0.283 mm, and Ns (Number of circumferential micro-fins per circle) of 40-50.It shows that the heat transfer enhanced ratios is usually ranging from 2.3-3.64. The friction factor relative to the smooth tube are about 1.8 to 3.3 times higher. Analyzing the effect of rib geometry on flow and heat transfer, it was found that the higher the height of the internal rib, the better the enhancement of convective heat transfer in the tube. The greater the thickness of the rib tip and base, the more detrimental to the friction factor in the tube. It had not noticeable influence on the heat transfer performance as the helix angle increases from 45° to 50°. For the increase of Ns, it appears that 45 ribs per circle is the best value in the present study when considering the increase in pressure loss. The thermal-hydraulic performance of eleven tubes were also evaluated. It shows that Tube-1 had the best performance in the condensing tubes and Tube-7 had the best performance in the boiling tubes.","PeriodicalId":50208,"journal":{"name":"Journal of Enhanced Heat Transfer","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Enhanced Heat Transfer","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1615/jenhheattransf.2024051809","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The flow and heat transfer experiments are conducted in this paper for eleven internally grooved tubes. Refrigerants are boiling or condensing outside the tube. The experimental tubes have the internal helical rib heights of 0.25-0.36 mm, helix angles of 40-60°, rib base thicknesses of 0.40-0.79 mm, rib tip thicknesses of 0.078-0.283 mm, and Ns (Number of circumferential micro-fins per circle) of 40-50.It shows that the heat transfer enhanced ratios is usually ranging from 2.3-3.64. The friction factor relative to the smooth tube are about 1.8 to 3.3 times higher. Analyzing the effect of rib geometry on flow and heat transfer, it was found that the higher the height of the internal rib, the better the enhancement of convective heat transfer in the tube. The greater the thickness of the rib tip and base, the more detrimental to the friction factor in the tube. It had not noticeable influence on the heat transfer performance as the helix angle increases from 45° to 50°. For the increase of Ns, it appears that 45 ribs per circle is the best value in the present study when considering the increase in pressure loss. The thermal-hydraulic performance of eleven tubes were also evaluated. It shows that Tube-1 had the best performance in the condensing tubes and Tube-7 had the best performance in the boiling tubes.
几何参数对内部螺旋肋形管热液压性能的影响
本文对 11 根内槽管进行了流动和传热实验。制冷剂在管外沸腾或冷凝。实验管的内螺旋肋高度为 0.25-0.36 毫米,螺旋角为 40-60°,肋底厚度为 0.40-0.79 毫米,肋尖厚度为 0.078-0.283 毫米,Ns(每圈圆周微鳍数)为 40-50。与光滑管相比,摩擦系数大约高出 1.8 至 3.3 倍。分析肋条几何形状对流动和传热的影响时发现,内肋条高度越高,管内对流传热的增强效果越好。肋条顶端和底部的厚度越大,对管内的摩擦系数越不利。当螺旋角从 45°增加到 50°时,对传热性能的影响并不明显。对于 Ns 的增加,考虑到压力损失的增加,本研究中每圈 45 根肋条似乎是最佳值。还对 11 个管道的热液压性能进行了评估。结果表明,1 号管在冷凝管中性能最佳,7 号管在沸腾管中性能最佳。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Enhanced Heat Transfer
Journal of Enhanced Heat Transfer 工程技术-工程:机械
CiteScore
3.60
自引率
8.70%
发文量
51
审稿时长
12 months
期刊介绍: The Journal of Enhanced Heat Transfer will consider a wide range of scholarly papers related to the subject of "enhanced heat and mass transfer" in natural and forced convection of liquids and gases, boiling, condensation, radiative heat transfer. Areas of interest include: ■Specially configured surface geometries, electric or magnetic fields, and fluid additives - all aimed at enhancing heat transfer rates. Papers may include theoretical modeling, experimental techniques, experimental data, and/or application of enhanced heat transfer technology. ■The general topic of "high performance" heat transfer concepts or systems is also encouraged.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信