Comparing Simulation Training of Bronchoscopy-Guided Percutaneous Dilatational Tracheostomy Using Conventional Versus 3D Printed Simulators (TRAC-Sim Study).
Moritz Wegner, Fabian Dusse, Finnard Beeser, Nicolas Leister, Marian Lefarth, Simon-Richard Finke, Bernd W Böttiger, Bernhard Dorweiler, Sandra Emily Stoll
{"title":"Comparing Simulation Training of Bronchoscopy-Guided Percutaneous Dilatational Tracheostomy Using Conventional Versus 3D Printed Simulators (TRAC-Sim Study).","authors":"Moritz Wegner, Fabian Dusse, Finnard Beeser, Nicolas Leister, Marian Lefarth, Simon-Richard Finke, Bernd W Böttiger, Bernhard Dorweiler, Sandra Emily Stoll","doi":"10.1177/08850666241232918","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Individual implementation rate of bronchoscopy-guided percutaneous dilatational tracheostomy (PDT) varies among intensivists. Simulation training (ST) can increase the safety of medical procedures by reducing stress levels of the performing team. The aim of this study was to evaluate the benefit of ST in PDT regarding procedural time, quality of performance, and percepted feelings of safety of the proceduralist and to compare conventional simulators (CSIM) with simulators generated from 3D printers (3DSIM). <b>Methods:</b> We conducted a prospective, single-center, randomized, blinded cross-over study comparing the benefit of CSIM versus 3DSIM for ST of PDT. Participants underwent a standardized theoretical training and were randomized to ST with CSIM (group A) or 3DSIM (group B). After ST, participants' performance was assessed by two blinded examiners on a porcine trachea regarding time required for successful completion of PDT and correct performance (assessed by a performance score). Percepted feelings of safety were assessed before and after ST. This was followed by a second training and second assessment of the same aspects with crossed groups. <b>Results:</b> 44 participants were included: 24 initially trained with CSIM (group A) and 20 with 3DSIM (group B). Correctness of the PDT performance increased significantly in group B (p < .01) and not significantly in group A (p = .14). Mean procedural time required for performing a PDT after their second ST compared to the first assessment (p < .01) was lower with no difference between group A and group B and irrespective of the participants' previous experience regarding PDT, age, and sex. Moreover, percepted feelings of safety increased after the first ST in both groups (p < .001). <b>Conclusions:</b> ST can improve procedural skills, procedural time, and percepted feelings of safety of the proceduralist in simulated PDT.</p>","PeriodicalId":16307,"journal":{"name":"Journal of Intensive Care Medicine","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Intensive Care Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08850666241232918","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Individual implementation rate of bronchoscopy-guided percutaneous dilatational tracheostomy (PDT) varies among intensivists. Simulation training (ST) can increase the safety of medical procedures by reducing stress levels of the performing team. The aim of this study was to evaluate the benefit of ST in PDT regarding procedural time, quality of performance, and percepted feelings of safety of the proceduralist and to compare conventional simulators (CSIM) with simulators generated from 3D printers (3DSIM). Methods: We conducted a prospective, single-center, randomized, blinded cross-over study comparing the benefit of CSIM versus 3DSIM for ST of PDT. Participants underwent a standardized theoretical training and were randomized to ST with CSIM (group A) or 3DSIM (group B). After ST, participants' performance was assessed by two blinded examiners on a porcine trachea regarding time required for successful completion of PDT and correct performance (assessed by a performance score). Percepted feelings of safety were assessed before and after ST. This was followed by a second training and second assessment of the same aspects with crossed groups. Results: 44 participants were included: 24 initially trained with CSIM (group A) and 20 with 3DSIM (group B). Correctness of the PDT performance increased significantly in group B (p < .01) and not significantly in group A (p = .14). Mean procedural time required for performing a PDT after their second ST compared to the first assessment (p < .01) was lower with no difference between group A and group B and irrespective of the participants' previous experience regarding PDT, age, and sex. Moreover, percepted feelings of safety increased after the first ST in both groups (p < .001). Conclusions: ST can improve procedural skills, procedural time, and percepted feelings of safety of the proceduralist in simulated PDT.
期刊介绍:
Journal of Intensive Care Medicine (JIC) is a peer-reviewed bi-monthly journal offering medical and surgical clinicians in adult and pediatric intensive care state-of-the-art, broad-based analytic reviews and updates, original articles, reports of large clinical series, techniques and procedures, topic-specific electronic resources, book reviews, and editorials on all aspects of intensive/critical/coronary care.