{"title":"[Development of a Three-Wavelength Brain Tissue Oxygen Monitoring System Based on Near Infrared Spectrum].","authors":"Zexi Li, Hanlin Li, Qi Yin, Shijie Cai, Jilun Ye, Xu Zhang, Hui Yu, Dahai Gou","doi":"10.3969/j.issn.1671-7104.230207","DOIUrl":null,"url":null,"abstract":"<p><p>In the past 20 years, near infrared spectrum technology has been widely used in human body monitoring due to its non-invasive and real-time characteristics. Oxygen, as the main metabolic substance of the human body, is consumed the most in brain tissue. In order to prevent complications caused by a decrease in brain tissue oxygen during treatment, the patient's brain tissue blood oxygen saturation needs to be monitored in real time. Currently, most of the clinically used non-invasive cerebral blood oxygen detection equipments use dual wavelengths. Other substances on the detection path will cause errors in the measurement results. Therefore, this article proposes a three-wavelength method based on the basic principle of non-invasive monitoring of cerebral blood oxygen using near-infrared spectrum. The brain tissue oxygen saturation monitoring method of detecting light sources was initially verified through the built system, laying the foundation for subsequent system engineering.</p>","PeriodicalId":52535,"journal":{"name":"中国医疗器械杂志","volume":"48 1","pages":"26-29"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国医疗器械杂志","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.3969/j.issn.1671-7104.230207","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
In the past 20 years, near infrared spectrum technology has been widely used in human body monitoring due to its non-invasive and real-time characteristics. Oxygen, as the main metabolic substance of the human body, is consumed the most in brain tissue. In order to prevent complications caused by a decrease in brain tissue oxygen during treatment, the patient's brain tissue blood oxygen saturation needs to be monitored in real time. Currently, most of the clinically used non-invasive cerebral blood oxygen detection equipments use dual wavelengths. Other substances on the detection path will cause errors in the measurement results. Therefore, this article proposes a three-wavelength method based on the basic principle of non-invasive monitoring of cerebral blood oxygen using near-infrared spectrum. The brain tissue oxygen saturation monitoring method of detecting light sources was initially verified through the built system, laying the foundation for subsequent system engineering.
期刊介绍:
Chinese Journal of Medical Instrumentation mainly reports on the development, progress, research and development, production, clinical application, management, and maintenance of medical devices and biomedical engineering. Its aim is to promote the exchange of information on medical devices and biomedical engineering in China and turn the journal into a high-quality academic journal that leads academic directions and advocates academic debates.