{"title":"Algorithmic detection of sleep-disordered breathing using respiratory signals: a systematic review.","authors":"Liqing Yang, Zhimei Ding, Jiangjie Zhou, Siyuan Zhang, Qi Wang, Kaige Zheng, Xing Wang, Lin Chen","doi":"10.1088/1361-6579/ad2c13","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background and Objective</i>. Sleep-disordered breathing (SDB) poses health risks linked to hypertension, cardiovascular disease, and diabetes. However, the time-consuming and costly standard diagnostic method, polysomnography (PSG), limits its wide adoption and leads to underdiagnosis. To tackle this, cost-effective algorithms using single-lead signals (like respiratory, blood oxygen, and electrocardiogram) have emerged. Despite respiratory signals being preferred for SDB assessment, a lack of comprehensive reviews addressing their algorithmic scope and performance persists. This paper systematically reviews 2012-2022 literature, covering signal sources, processing, feature extraction, classification, and application, aiming to bridge this gap and provide future research references.<i>Methods</i>. This systematic review followed the registered PROSPERO protocol (CRD42022385130), initially screening 342 papers, with 32 studies meeting data extraction criteria.<i>Results</i>. Respiratory signal sources include nasal airflow (NAF), oronasal airflow (OAF), and respiratory movement-related signals such as thoracic respiratory effort (TRE) and abdominal respiratory effort (ARE). Classification techniques include threshold rule-based methods (8), machine learning models (13), and deep learning models (11). The NAF-based algorithm achieved the highest average accuracy at 94.11%, surpassing 78.19% for other signals. Hypopnea detection sensitivity with single-source respiratory signals remained modest, peaking at 73.34%. The TRE and ARE signals proved to be reliable in identifying different types of SDB because distinct respiratory disorders exhibited different patterns of chest and abdominal motion.<i>Conclusions</i>. Multiple detection algorithms have been widely applied for SDB detection, and their accuracy is closely related to factors such as signal source, signal processing, feature selection, and model selection.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ad2c13","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background and Objective. Sleep-disordered breathing (SDB) poses health risks linked to hypertension, cardiovascular disease, and diabetes. However, the time-consuming and costly standard diagnostic method, polysomnography (PSG), limits its wide adoption and leads to underdiagnosis. To tackle this, cost-effective algorithms using single-lead signals (like respiratory, blood oxygen, and electrocardiogram) have emerged. Despite respiratory signals being preferred for SDB assessment, a lack of comprehensive reviews addressing their algorithmic scope and performance persists. This paper systematically reviews 2012-2022 literature, covering signal sources, processing, feature extraction, classification, and application, aiming to bridge this gap and provide future research references.Methods. This systematic review followed the registered PROSPERO protocol (CRD42022385130), initially screening 342 papers, with 32 studies meeting data extraction criteria.Results. Respiratory signal sources include nasal airflow (NAF), oronasal airflow (OAF), and respiratory movement-related signals such as thoracic respiratory effort (TRE) and abdominal respiratory effort (ARE). Classification techniques include threshold rule-based methods (8), machine learning models (13), and deep learning models (11). The NAF-based algorithm achieved the highest average accuracy at 94.11%, surpassing 78.19% for other signals. Hypopnea detection sensitivity with single-source respiratory signals remained modest, peaking at 73.34%. The TRE and ARE signals proved to be reliable in identifying different types of SDB because distinct respiratory disorders exhibited different patterns of chest and abdominal motion.Conclusions. Multiple detection algorithms have been widely applied for SDB detection, and their accuracy is closely related to factors such as signal source, signal processing, feature selection, and model selection.
期刊介绍:
Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation.
Papers are published on topics including:
applied physiology in illness and health
electrical bioimpedance, optical and acoustic measurement techniques
advanced methods of time series and other data analysis
biomedical and clinical engineering
in-patient and ambulatory monitoring
point-of-care technologies
novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems.
measurements in molecular, cellular and organ physiology and electrophysiology
physiological modeling and simulation
novel biomedical sensors, instruments, devices and systems
measurement standards and guidelines.