{"title":"An assessment of exposed syringe inner walls as a route of exposure from hazardous drugs.","authors":"Blake T Barta, Lori T Armistead, Stephen F Eckel","doi":"10.1177/10781552241231511","DOIUrl":null,"url":null,"abstract":"<p><p>IntroductionMaintaining safe working environments for health care personnel, especially for those who regularly handle hazardous drugs (HDs), is of utmost importance. Studies have shown that when closed system transfer devices (CSTDs) are used with standard open barrel syringes, cyclophosphamide (CP), a commonly used HD, is transferred to the syringe plunger during compounding or administration processes. This contamination can then be transferred to the work environment, endangering workers.PurposeThe purpose of this study was to quantify HD contamination of the inner surface of standard open barrel syringes and to compare contamination levels between three commonly used HDs: 5-fluorouracil (5-FU), CP, and ifosfamide (IF).MethodsEach HD was transferred from a vial to an intravenous (IV) bag using a standard open barrel syringe and Becton, Dickinson and Company (BD) PhaSeal<sup>TM</sup> CSTD connectors. Samples were taken from the inner surface of each of the syringe barrels to measure the amount of HD contamination. Each drug was tested 15 times and compared to a positive control.ResultsSignificant amounts of each drug were transferred to the inner surfaces of the syringes. The average amounts of each drug measured were: 5-FU, 1327.7 ng (standard deviation [SD] = 873.6 ng); CP, 1074.8 ng (SD = 481.6 ng); and IF, 1700.0 ng (SD = 1098.1 ng). There was no statistically significant difference between the three drugs (<i>p</i> = 0.14).ConclusionThis study underscores the presence of HD contamination on standard open barrel syringe inner surfaces after transfer of drug from vial to syringe to IV bag. Such contamination could be spread in the working environment and expose health care workers to harm.</p>","PeriodicalId":16637,"journal":{"name":"Journal of Oncology Pharmacy Practice","volume":" ","pages":"219-223"},"PeriodicalIF":1.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Oncology Pharmacy Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10781552241231511","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/20 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
IntroductionMaintaining safe working environments for health care personnel, especially for those who regularly handle hazardous drugs (HDs), is of utmost importance. Studies have shown that when closed system transfer devices (CSTDs) are used with standard open barrel syringes, cyclophosphamide (CP), a commonly used HD, is transferred to the syringe plunger during compounding or administration processes. This contamination can then be transferred to the work environment, endangering workers.PurposeThe purpose of this study was to quantify HD contamination of the inner surface of standard open barrel syringes and to compare contamination levels between three commonly used HDs: 5-fluorouracil (5-FU), CP, and ifosfamide (IF).MethodsEach HD was transferred from a vial to an intravenous (IV) bag using a standard open barrel syringe and Becton, Dickinson and Company (BD) PhaSealTM CSTD connectors. Samples were taken from the inner surface of each of the syringe barrels to measure the amount of HD contamination. Each drug was tested 15 times and compared to a positive control.ResultsSignificant amounts of each drug were transferred to the inner surfaces of the syringes. The average amounts of each drug measured were: 5-FU, 1327.7 ng (standard deviation [SD] = 873.6 ng); CP, 1074.8 ng (SD = 481.6 ng); and IF, 1700.0 ng (SD = 1098.1 ng). There was no statistically significant difference between the three drugs (p = 0.14).ConclusionThis study underscores the presence of HD contamination on standard open barrel syringe inner surfaces after transfer of drug from vial to syringe to IV bag. Such contamination could be spread in the working environment and expose health care workers to harm.
期刊介绍:
Journal of Oncology Pharmacy Practice is a peer-reviewed scholarly journal dedicated to educating health professionals about providing pharmaceutical care to patients with cancer. It is the official publication of the International Society for Oncology Pharmacy Practitioners (ISOPP). Publishing pertinent case reports and consensus guidelines...