Modelling the Impact of Array Wiring on Electrical Output of Vertical Bifacial Agrivoltaic Installations

Ross Rucker, Dunbar Birnie
{"title":"Modelling the Impact of Array Wiring on Electrical Output of Vertical Bifacial Agrivoltaic Installations","authors":"Ross Rucker, Dunbar Birnie","doi":"10.52825/agripv.v1i.701","DOIUrl":null,"url":null,"abstract":"We present a model and study investigating the potential power output of vertical bifacial solar panels on New Jersey farms. The simulation calculates instantaneous brightness and shading based on the position of the sun and adjacent rows of panels, and uses that to calculate current and voltage values. We explore different strategies to improve the power output further. Double-high modules, which use two panels stacked together, offer significant gains per acre with only a modest increase of inter-row shading. When bypass diodes and improved inverter wiring are also used, much of the losses due to shading are avoided, and the total power output per acre is nearly doubled. In a double high configuration it is advantageous to have the top and bottom modules on separate inverter strings.","PeriodicalId":517222,"journal":{"name":"AgriVoltaics Conference Proceedings","volume":"2 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AgriVoltaics Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52825/agripv.v1i.701","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We present a model and study investigating the potential power output of vertical bifacial solar panels on New Jersey farms. The simulation calculates instantaneous brightness and shading based on the position of the sun and adjacent rows of panels, and uses that to calculate current and voltage values. We explore different strategies to improve the power output further. Double-high modules, which use two panels stacked together, offer significant gains per acre with only a modest increase of inter-row shading. When bypass diodes and improved inverter wiring are also used, much of the losses due to shading are avoided, and the total power output per acre is nearly doubled. In a double high configuration it is advantageous to have the top and bottom modules on separate inverter strings.
模拟阵列布线对垂直双面农用光伏设备电力输出的影响
我们介绍了一个模型,并对新泽西农场垂直双面太阳能电池板的潜在功率输出进行了研究。模拟根据太阳的位置和相邻几排太阳能电池板计算瞬时亮度和阴影,并以此计算电流和电压值。我们探索了进一步提高功率输出的不同策略。双高组件是将两块电池板堆叠在一起,每英亩的发电量可显著提高,但行间遮光率仅略有增加。如果同时使用旁路二极管和改进的逆变器布线,则可避免遮光造成的大部分损失,每英亩的总功率输出几乎翻了一番。在双高配置中,将顶部和底部组件分别置于不同的逆变器串上是非常有利的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信