Experimental Methods for Measuring the Efficiency of a Molten Salt Central Receiver

María Fernández-Torrijos, Cathy Frantz, Jana Stengler, Marc Röger, Tim Schlichting, Reiner Buck
{"title":"Experimental Methods for Measuring the Efficiency of a Molten Salt Central Receiver","authors":"María Fernández-Torrijos, Cathy Frantz, Jana Stengler, Marc Röger, Tim Schlichting, Reiner Buck","doi":"10.52825/solarpaces.v1i.715","DOIUrl":null,"url":null,"abstract":"In this work, two different methods for measuring the efficiency of central receivers are analyzed by the case of the High Performance Molten Salt II Project (HPMS-II): the continuous power-on method, and the semi-analytical method. The main difference between the two methods is the procedure to calculate the thermal losses of the receiver: on the one hand, the continuous power-on method calculates the thermal losses from the measurement of the absorbed power by the molten salt for different measured incident powers on the receiver. Here, it is assumed that the thermal losses are independent of the incident power if the molten salt temperature is kept constant. On the other hand, the semi-analytical method calculates the thermal losses as the sum of convective and radiative losses, calculated directly from the Newton and Stefan-Boltzmann equations by measuring the temperature of the tube surface, the ambient temperature, and the wind speed. Therefore, the calculation of the thermal losses is independent from one method to another. The procedure of applying these methods during the experimental test campaign of the HPMS-II receiver is detailed in this paper. Additionally, an uncertainty analysis of both methods is conducted to determine the uncertainty expected for the receiver efficiency measurements.","PeriodicalId":506238,"journal":{"name":"SolarPACES Conference Proceedings","volume":"117 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SolarPACES Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52825/solarpaces.v1i.715","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, two different methods for measuring the efficiency of central receivers are analyzed by the case of the High Performance Molten Salt II Project (HPMS-II): the continuous power-on method, and the semi-analytical method. The main difference between the two methods is the procedure to calculate the thermal losses of the receiver: on the one hand, the continuous power-on method calculates the thermal losses from the measurement of the absorbed power by the molten salt for different measured incident powers on the receiver. Here, it is assumed that the thermal losses are independent of the incident power if the molten salt temperature is kept constant. On the other hand, the semi-analytical method calculates the thermal losses as the sum of convective and radiative losses, calculated directly from the Newton and Stefan-Boltzmann equations by measuring the temperature of the tube surface, the ambient temperature, and the wind speed. Therefore, the calculation of the thermal losses is independent from one method to another. The procedure of applying these methods during the experimental test campaign of the HPMS-II receiver is detailed in this paper. Additionally, an uncertainty analysis of both methods is conducted to determine the uncertainty expected for the receiver efficiency measurements.
测量熔盐中央接收器效率的实验方法
在这项工作中,以高性能熔盐二期项目(HPMS-II)为例,分析了测量中央接收器效率的两种不同方法:连续通电法和半分析法。这两种方法的主要区别在于计算接收器热损耗的程序:一方面,连续通电法通过测量接收器上不同测量入射功率下熔盐的吸收功率来计算热损耗。这里假定,如果熔盐温度保持不变,热损耗与入射功率无关。另一方面,半解析法将热损失计算为对流损失和辐射损失之和,通过测量管道表面温度、环境温度和风速,直接根据牛顿和斯蒂芬-玻尔兹曼方程计算得出。因此,热损失的计算与其他方法无关。本文详细介绍了在 HPMS-II 接收器的实验测试活动中应用这些方法的程序。此外,还对两种方法进行了不确定性分析,以确定接收机效率测量的预期不确定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信