{"title":"Development and implementation of an automated four-terminal-pair Josephson impedance bridge","authors":"Yoawaret Pimsut, S. Bauer, M. Kraus, Ralf Behr, M. Kruskopf, O.F. Kieler, L. Palafox","doi":"10.1088/1681-7575/ad2539","DOIUrl":null,"url":null,"abstract":"\n The four-terminal-pair impedance bridge using pulse-driven Josephson voltage standards at PTB has been fully automated. The same bridge configuration was employed to determine R:R and C:C ratios over the frequency range between 53 Hz to 50 kHz. Only minor changes are needed to cover this large frequency range: amplifiers to increase the sensitivities of the current detections for low frequencies and signal generators with higher resolutions at high frequencies to reach 50 kHz. Furthermore, the bridge can be operated for quadrature R:(1/ωC) measurements. The combined standard uncertainties (k = 1) for the new bridge were evaluated for all operating frequencies. They reach 2 nF/F and 4 nΩ/Ω at 1233.15 Hz. At this frequency, the 10 nF:10 nF ratio matched the ratio of PTB's bridge employing inductive voltage dividers within 1 nF/F ± 3 nF/F (k = 1). Over 45 days, the 10 nF:10 nF ratio deviated less than -2 nF/F ± 3 nF/F (k = 1). The 12.9 kΩ:10 kΩ ratio at 53 Hz differed -2 nΩ/Ω ± 5 nΩ/Ω (k = 1) from the DC ratio measured by the PTB's cryogenic current comparator bridge. Using a 12.9 kΩ resistance standard and a graphene AC quantum Hall resistance, the 10 nF:10 nF ratios derived from quadrature measurements agreed with the PTB's inductive voltage divider bridge better than 9 nF/F ± 13 nF/F (k = 1).","PeriodicalId":18444,"journal":{"name":"Metrologia","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrologia","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1681-7575/ad2539","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

The four-terminal-pair impedance bridge using pulse-driven Josephson voltage standards at PTB has been fully automated. The same bridge configuration was employed to determine R:R and C:C ratios over the frequency range between 53 Hz to 50 kHz. Only minor changes are needed to cover this large frequency range: amplifiers to increase the sensitivities of the current detections for low frequencies and signal generators with higher resolutions at high frequencies to reach 50 kHz. Furthermore, the bridge can be operated for quadrature R:(1/ωC) measurements. The combined standard uncertainties (k = 1) for the new bridge were evaluated for all operating frequencies. They reach 2 nF/F and 4 nΩ/Ω at 1233.15 Hz. At this frequency, the 10 nF:10 nF ratio matched the ratio of PTB's bridge employing inductive voltage dividers within 1 nF/F ± 3 nF/F (k = 1). Over 45 days, the 10 nF:10 nF ratio deviated less than -2 nF/F ± 3 nF/F (k = 1). The 12.9 kΩ:10 kΩ ratio at 53 Hz differed -2 nΩ/Ω ± 5 nΩ/Ω (k = 1) from the DC ratio measured by the PTB's cryogenic current comparator bridge. Using a 12.9 kΩ resistance standard and a graphene AC quantum Hall resistance, the 10 nF:10 nF ratios derived from quadrature measurements agreed with the PTB's inductive voltage divider bridge better than 9 nF/F ± 13 nF/F (k = 1).
自动四端对约瑟夫森阻抗桥的开发与实施
PTB 使用脉冲驱动约瑟夫森电压标准的四端对阻抗电桥已实现完全自动化。在 53 Hz 至 50 kHz 的频率范围内,采用相同的电桥配置来测定 R:R 和 C:C 比率。要覆盖如此大的频率范围,只需稍作改动即可:在低频时使用放大器提高电流检测的灵敏度,在高频时使用分辨率更高的信号发生器以达到 50 kHz。此外,电桥还可用于正交 R:(1/ωC)测量。新型电桥的综合标准不确定度(k = 1)已针对所有工作频率进行了评估。在 1233.15 Hz 时,标准不确定度为 2 nF/F 和 4 nΩ/Ω。在此频率下,10 nF:10 nF 的比率与 PTB 采用电感分压器的电桥比率相匹配,在 1 nF/F ± 3 nF/F (k = 1)的范围内。在 45 天内,10 nF:10 nF 比率的偏差小于 -2 nF/F ± 3 nF/F (k = 1)。在 53 Hz 频率下,12.9 kΩ:10 kΩ 的比率与 PTB 的低温电流比较器电桥测得的直流比率相差 -2 nΩ/Ω ± 5 nΩ/Ω (k = 1)。使用 12.9 kΩ 电阻标准和石墨烯交流量子霍尔电阻,正交测量得出的 10 nF:10 nF 比率与 PTB 的电感分压电桥的吻合度优于 9 nF/F ± 13 nF/F (k = 1)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Metrologia
Metrologia 工程技术-物理:应用
CiteScore
2.80
自引率
25.00%
发文量
137
审稿时长
12 months
期刊介绍: Published 6 times per year, Metrologia covers the fundamentals of measurements, particularly those dealing with the seven base units of the International System of Units (metre, kilogram, second, ampere, kelvin, candela, mole) or proposals to replace them. The journal also publishes papers that contribute to the solution of difficult measurement problems and improve the accuracy of derived units and constants that are of fundamental importance to physics. In addition to regular papers, the journal publishes review articles, issues devoted to single topics of timely interest and occasional conference proceedings. Letters to the Editor and Short Communications (generally three pages or less) are also considered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信