Disposable Voltammetric Immunosensor for Determination and Quantification of Biomarker CA 15-3 in Biological Specimens

Analytica Pub Date : 2024-02-02 DOI:10.3390/analytica5010005
A. E. F. Oliveira, Arnaldo César Pereira, Mayra A. C. Resende, L. F. Ferreira
{"title":"Disposable Voltammetric Immunosensor for Determination and Quantification of Biomarker CA 15-3 in Biological Specimens","authors":"A. E. F. Oliveira, Arnaldo César Pereira, Mayra A. C. Resende, L. F. Ferreira","doi":"10.3390/analytica5010005","DOIUrl":null,"url":null,"abstract":"A disposable voltammetric immunosensor was developed to measure breast cancer biomarker 15-3 (CA 15-3) in human saliva and serum samples. Screen-printed paper-based electrodes (f-SPE) previously fabricated by our research group using homemade conductive inks were used as transducers, which were later modified only with gold nanoparticles to immobilize anti-CA 15-3 antibodies. The sensor was operated using antigen–antibody interactions in conjunction with a redox species (ferrocyanide potassium) for the indirect determination of the CA 15-3 antigen. The device characterization involved atomic force microscopy (AFM) and electrochemical analysis. Optimization of the construction and response of the immunosensor was achieved at incubation times of 6 h for anti-CA 15-3, 1 h for bovine serum albumin, and 1 h for interaction with CA 15-3. The sensor displays a linear range between 2 and 16 U/mL, with a sensitivity of 0.012 μA/U mL−1, a limit of detection (LOD) of 0.56 U/mL, and a limit of quantification (LOQ) of 1.88 U/mL. The interfering substances minimally affected the signal, with 4.94% response variation, and the reproducibility of the immunosensor demonstrated a relative standard deviation (RSD) of 5.65%. The sensor successfully determined the CA 15-3 concentration in human serum and saliva, demonstrating its potential for clinical analysis.","PeriodicalId":7829,"journal":{"name":"Analytica","volume":"84 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/analytica5010005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A disposable voltammetric immunosensor was developed to measure breast cancer biomarker 15-3 (CA 15-3) in human saliva and serum samples. Screen-printed paper-based electrodes (f-SPE) previously fabricated by our research group using homemade conductive inks were used as transducers, which were later modified only with gold nanoparticles to immobilize anti-CA 15-3 antibodies. The sensor was operated using antigen–antibody interactions in conjunction with a redox species (ferrocyanide potassium) for the indirect determination of the CA 15-3 antigen. The device characterization involved atomic force microscopy (AFM) and electrochemical analysis. Optimization of the construction and response of the immunosensor was achieved at incubation times of 6 h for anti-CA 15-3, 1 h for bovine serum albumin, and 1 h for interaction with CA 15-3. The sensor displays a linear range between 2 and 16 U/mL, with a sensitivity of 0.012 μA/U mL−1, a limit of detection (LOD) of 0.56 U/mL, and a limit of quantification (LOQ) of 1.88 U/mL. The interfering substances minimally affected the signal, with 4.94% response variation, and the reproducibility of the immunosensor demonstrated a relative standard deviation (RSD) of 5.65%. The sensor successfully determined the CA 15-3 concentration in human serum and saliva, demonstrating its potential for clinical analysis.
用于测定和定量生物样本中生物标记物 CA 15-3 的一次性伏安法免疫传感器
我们开发了一种一次性伏安免疫传感器,用于测量人体唾液和血清样本中的乳腺癌生物标记物 15-3 (CA15-3)。我们的研究小组以前用自制导电油墨制作的丝网印刷纸基电极(f-SPE)被用作传感器,后来仅用金纳米粒子对其进行了修饰,以固定抗 CA 15-3 抗体。该传感器利用抗原-抗体之间的相互作用以及氧化还原物质(亚铁氰化钾)来间接测定 CA 15-3 抗原。该装置的表征包括原子力显微镜(AFM)和电化学分析。抗 CA 15-3 的孵育时间为 6 小时,牛血清白蛋白的孵育时间为 1 小时,与 CA 15-3 相互作用的孵育时间为 1 小时,在这些条件下对免疫传感器的构造和响应进行了优化。该传感器的线性范围为 2 至 16 U/mL,灵敏度为 0.012 μA/U mL-1,检出限(LOD)为 0.56 U/mL,定量限(LOQ)为 1.88 U/mL。干扰物质对信号的影响很小,反应变异率为 4.94%,免疫传感器的重现性相对标准偏差(RSD)为 5.65%。该传感器成功测定了人体血清和唾液中的 CA 15-3 浓度,证明了其在临床分析中的应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信