Easy-to-Use Chemiluminescent-Based Assay for a Rapid and Low-Cost Evaluation of the Antioxidant Activity of Cosmetic Products

IF 3.7 3区 工程技术 Q2 CHEMISTRY, ANALYTICAL
Seyedeh Rojin Shariati Pour, D. Calabria, A. Nascetti, D. Caputo, G. de Cesare, Massimo Guardigli, M. Zangheri, M. Mirasoli
{"title":"Easy-to-Use Chemiluminescent-Based Assay for a Rapid and Low-Cost Evaluation of the Antioxidant Activity of Cosmetic Products","authors":"Seyedeh Rojin Shariati Pour, D. Calabria, A. Nascetti, D. Caputo, G. de Cesare, Massimo Guardigli, M. Zangheri, M. Mirasoli","doi":"10.3390/chemosensors12020025","DOIUrl":null,"url":null,"abstract":"New cosmetic formulations are continuously requested by the market and the ingredients are constantly evolving. Recently the use of antioxidants has gained success and, in this context, analytical methods able to quickly and easily assess the antioxidant activity of cosmetics would make it possible to carry out analyses on new formulations even within the manufacturing process without the need for specialized laboratories and personnel, thus evaluating directly on-site the effectiveness and the shelf life of products. In this work, a chemiluminescent inhibition assay was developed for determining the total antioxidant activity in cosmetic products. The method was based on the luminol/enhancers/hydrogen peroxide/horseradish peroxidase chemiluminescent system, which generates light signals measurable through simple and compact instrumentation. The formation of the chemiluminescent signal is inhibited by the presence of antioxidant substances while it is restored once all the antioxidant molecules have been oxidized. The time of appearance of the light signal is related to the total antioxidant activity. The assay was carried out exploiting an integrated device comprising a microwell plate coupled with an array of amorphous silicon hydrogenated photosensors enclosed in a mini-dark box. The method was optimized in terms of concentrations and volumes of the required reagents and sample pre-treatment. A calibration curve was generated taking as a reference the antioxidant activity of ascorbic acid obtaining a detection limit of 10 µM. The developed method was applied to cosmetic products currently on the market as well as on spiked samples in order to evaluate the performance of the methods in terms of sensitivity, accuracy, and reproducibility.","PeriodicalId":10057,"journal":{"name":"Chemosensors","volume":null,"pages":null},"PeriodicalIF":3.7000,"publicationDate":"2024-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemosensors","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/chemosensors12020025","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

New cosmetic formulations are continuously requested by the market and the ingredients are constantly evolving. Recently the use of antioxidants has gained success and, in this context, analytical methods able to quickly and easily assess the antioxidant activity of cosmetics would make it possible to carry out analyses on new formulations even within the manufacturing process without the need for specialized laboratories and personnel, thus evaluating directly on-site the effectiveness and the shelf life of products. In this work, a chemiluminescent inhibition assay was developed for determining the total antioxidant activity in cosmetic products. The method was based on the luminol/enhancers/hydrogen peroxide/horseradish peroxidase chemiluminescent system, which generates light signals measurable through simple and compact instrumentation. The formation of the chemiluminescent signal is inhibited by the presence of antioxidant substances while it is restored once all the antioxidant molecules have been oxidized. The time of appearance of the light signal is related to the total antioxidant activity. The assay was carried out exploiting an integrated device comprising a microwell plate coupled with an array of amorphous silicon hydrogenated photosensors enclosed in a mini-dark box. The method was optimized in terms of concentrations and volumes of the required reagents and sample pre-treatment. A calibration curve was generated taking as a reference the antioxidant activity of ascorbic acid obtaining a detection limit of 10 µM. The developed method was applied to cosmetic products currently on the market as well as on spiked samples in order to evaluate the performance of the methods in terms of sensitivity, accuracy, and reproducibility.
基于化学发光的检测方法易于使用,可快速、低成本地评估化妆品的抗氧化活性
市场不断需要新的化妆品配方,成分也在不断变化。最近,抗氧化剂的使用取得了成功,在这种情况下,如果有一种分析方法能够快速、简便地评估化妆品的抗氧化活性,那么即使在生产过程中也可以对新配方进行分析,而不需要专门的实验室和人员,从而可以直接现场评估产品的功效和保质期。这项研究开发了一种化学发光抑制测定法,用于测定化妆品中的总抗氧化活性。该方法基于鲁米诺/增强剂/过氧化氢/辣根过氧化物酶化学发光系统,该系统产生的光信号可通过简单紧凑的仪器进行测量。抗氧化物质的存在会抑制化学发光信号的形成,而一旦所有抗氧化分子都被氧化,信号就会恢复。光信号出现的时间与总的抗氧化活性有关。该检测方法是利用一个集成装置进行的,该装置包括一个微孔板和一个封装在微型暗箱中的非晶硅氢化光敏元件阵列。该方法在所需试剂的浓度和体积以及样品预处理方面进行了优化。以抗坏血酸的抗氧化活性为参考,生成了一条校准曲线,检测限为 10 µM。为了评估该方法在灵敏度、准确性和重现性方面的性能,我们将所开发的方法应用于目前市场上的化妆品以及添加样品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Chemosensors
Chemosensors Chemistry-Analytical Chemistry
CiteScore
5.00
自引率
9.50%
发文量
450
审稿时长
11 weeks
期刊介绍: Chemosensors (ISSN 2227-9040; CODEN: CHEMO9) is an international, scientific, open access journal on the science and technology of chemical sensors published quarterly online by MDPI.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信