An EIRP Measurement Method of High-Power Microwave Systems Based on Near-Field Testing

IF 1.2 4区 计算机科学 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC
Xianggang Hu, Jiancang Su, Mingtao Zhang, Xi Li, Dingkun Ma, Jingang Gong, Kewei Cheng, Jia Liu, Jiande Zhang, Rui Li, Jie Cheng, Shaotong Wu
{"title":"An EIRP Measurement Method of High-Power Microwave Systems Based on Near-Field Testing","authors":"Xianggang Hu, Jiancang Su, Mingtao Zhang, Xi Li, Dingkun Ma, Jingang Gong, Kewei Cheng, Jia Liu, Jiande Zhang, Rui Li, Jie Cheng, Shaotong Wu","doi":"10.1155/2024/2048009","DOIUrl":null,"url":null,"abstract":"The equivalent isotropic radiated power (EIRP) of high-power microwave (HPM) systems is a core-evaluating indicator. In practical testing, locating a suitable test site for the far-field method becomes challenging due to the requisite antenna separation. The conventional near-field method necessitates the extraction of the antenna’s near-field distribution, resulting in a testing system of intricate complexity and diminished efficiency. Therefore, the traditional near-field method cannot be directly applied in HPM systems. In the present study, a new EIRP measurement method for HPM systems based on near-field testing was proposed. First, a monitoring antenna of a considerable scale is positioned within the near-field vicinity of the HPM antenna to capture radiation power, thereby deriving its equivalent input power. Subsequently, according to the EIRP definition and the measured gain of the HPM antenna, the EIRP of the HPM system can be acquired. Theoretical research on this measurement method was conducted, the electromagnetic simulation model was constructed, and a comprehensive analysis through simulation was undertaken. A measurement system was developed and verified experimentally. The results demonstrate the precision of this approach in determining the EIRP of the HPM system, thereby serving as a valuable tool for assessing the power-handling capability of the HPM antenna. The test error is ±0.5 dB.","PeriodicalId":54392,"journal":{"name":"International Journal of Antennas and Propagation","volume":"2 1","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2024-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Antennas and Propagation","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.1155/2024/2048009","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The equivalent isotropic radiated power (EIRP) of high-power microwave (HPM) systems is a core-evaluating indicator. In practical testing, locating a suitable test site for the far-field method becomes challenging due to the requisite antenna separation. The conventional near-field method necessitates the extraction of the antenna’s near-field distribution, resulting in a testing system of intricate complexity and diminished efficiency. Therefore, the traditional near-field method cannot be directly applied in HPM systems. In the present study, a new EIRP measurement method for HPM systems based on near-field testing was proposed. First, a monitoring antenna of a considerable scale is positioned within the near-field vicinity of the HPM antenna to capture radiation power, thereby deriving its equivalent input power. Subsequently, according to the EIRP definition and the measured gain of the HPM antenna, the EIRP of the HPM system can be acquired. Theoretical research on this measurement method was conducted, the electromagnetic simulation model was constructed, and a comprehensive analysis through simulation was undertaken. A measurement system was developed and verified experimentally. The results demonstrate the precision of this approach in determining the EIRP of the HPM system, thereby serving as a valuable tool for assessing the power-handling capability of the HPM antenna. The test error is ±0.5 dB.
基于近场测试的大功率微波系统 EIRP 测量方法
高功率微波(HPM)系统的等效各向同性辐射功率(EIRP)是一项核心评估指标。在实际测试中,由于天线间距的要求,为远场法寻找合适的测试场地变得十分困难。传统的近场法需要提取天线的近场分布,导致测试系统错综复杂,效率降低。因此,传统的近场方法无法直接应用于 HPM 系统。本研究提出了一种基于近场测试的 HPM 系统 EIRP 测量新方法。首先,在 HPM 天线的近场附近放置一个相当规模的监测天线,以捕获辐射功率,从而得出其等效输入功率。然后,根据 EIRP 定义和 HPM 天线的测量增益,即可获得 HPM 系统的 EIRP。对这种测量方法进行了理论研究,建立了电磁仿真模型,并通过仿真进行了综合分析。开发了一个测量系统,并进行了实验验证。结果表明,这种方法可以精确地确定 HPM 系统的 EIRP,从而成为评估 HPM 天线功率处理能力的重要工具。测试误差为 ±0.5 dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Antennas and Propagation
International Journal of Antennas and Propagation ENGINEERING, ELECTRICAL & ELECTRONIC-TELECOMMUNICATIONS
CiteScore
3.10
自引率
13.30%
发文量
158
审稿时长
3.8 months
期刊介绍: International Journal of Antennas and Propagation publishes papers on the design, analysis, and applications of antennas, along with theoretical and practical studies relating the propagation of electromagnetic waves at all relevant frequencies, through space, air, and other media. As well as original research, the International Journal of Antennas and Propagation also publishes focused review articles that examine the state of the art, identify emerging trends, and suggest future directions for developing fields.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信