Elsie Effah Kaufmann, Richmond Tackie, J Benjamin Pitt, Samuel Mba, Bismark Akwetey, Danielle Quaye, Godfrey Mills, Clement Nyame, Henry Bulley, Matthew Glucksberg, Hassan Ghomrawi, William Appeadu-Mensah, Fizan Abdullah
{"title":"Feasibility of Leveraging Consumer Wearable Devices with Data Platform Integration for Patient Vital Monitoring in Low-Resource Settings.","authors":"Elsie Effah Kaufmann, Richmond Tackie, J Benjamin Pitt, Samuel Mba, Bismark Akwetey, Danielle Quaye, Godfrey Mills, Clement Nyame, Henry Bulley, Matthew Glucksberg, Hassan Ghomrawi, William Appeadu-Mensah, Fizan Abdullah","doi":"10.1155/2024/8906413","DOIUrl":null,"url":null,"abstract":"<p><p>Manual monitoring of vital signs, which often fails to capture the onset of deterioration, is the main monitoring modality in most Ghanaian hospitals due to the high cost and inadequate supply of patient bedside monitors. Consumer wearable devices (CWDs) are emerging, relatively low-cost technologies for continuous monitoring of physiological status; however, their validity has not been established in low-resource clinical settings. We aimed to (1) investigate the validity of the heart rate (HR) and oxygen saturation (SpO2) data from two widely used CWDs, the Fitbit Versa 2 and Xiaomi Mi Smart Band 6, against gold standard bedside monitors in one Ghanaian hospital and (2) develop a web application to capture and display CWD data in a clinician-friendly way. A healthy volunteer simultaneously wore both CWDs and blood pressure cuffs to measure HR and SpO2. To test for concordance, we conducted the Bland-Altman and mean absolute percentage error analyses. We also developed a web application that retrieves and displays CWD data in near real time as text and graphical trends. Compared to gold standards (patient monitor and manual), the Fitbit Versa 2 had 96.87% and 96.67% measurement accuracies for HR, and the Xiaomi Mi Smart Band 6 had 94.24% and 93.21% measurement accuracies for HR. The Xiaomi Mi Smart Band 6 had 98.79% measurement accuracy for SpO2. The strong concordance between CWD and gold standards supports the potential implementation of these devices as a novel method of vital sign monitoring to replace manual monitoring, thus saving costs and improving patient outcomes. Further studies are needed for confirmation.</p>","PeriodicalId":45630,"journal":{"name":"International Journal of Telemedicine and Applications","volume":"2024 ","pages":"8906413"},"PeriodicalIF":3.1000,"publicationDate":"2024-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10869189/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Telemedicine and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/8906413","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0
Abstract
Manual monitoring of vital signs, which often fails to capture the onset of deterioration, is the main monitoring modality in most Ghanaian hospitals due to the high cost and inadequate supply of patient bedside monitors. Consumer wearable devices (CWDs) are emerging, relatively low-cost technologies for continuous monitoring of physiological status; however, their validity has not been established in low-resource clinical settings. We aimed to (1) investigate the validity of the heart rate (HR) and oxygen saturation (SpO2) data from two widely used CWDs, the Fitbit Versa 2 and Xiaomi Mi Smart Band 6, against gold standard bedside monitors in one Ghanaian hospital and (2) develop a web application to capture and display CWD data in a clinician-friendly way. A healthy volunteer simultaneously wore both CWDs and blood pressure cuffs to measure HR and SpO2. To test for concordance, we conducted the Bland-Altman and mean absolute percentage error analyses. We also developed a web application that retrieves and displays CWD data in near real time as text and graphical trends. Compared to gold standards (patient monitor and manual), the Fitbit Versa 2 had 96.87% and 96.67% measurement accuracies for HR, and the Xiaomi Mi Smart Band 6 had 94.24% and 93.21% measurement accuracies for HR. The Xiaomi Mi Smart Band 6 had 98.79% measurement accuracy for SpO2. The strong concordance between CWD and gold standards supports the potential implementation of these devices as a novel method of vital sign monitoring to replace manual monitoring, thus saving costs and improving patient outcomes. Further studies are needed for confirmation.
期刊介绍:
The overall aim of the International Journal of Telemedicine and Applications is to bring together science and applications of medical practice and medical care at a distance as well as their supporting technologies such as, computing, communications, and networking technologies with emphasis on telemedicine techniques and telemedicine applications. It is directed at practicing engineers, academic researchers, as well as doctors, nurses, etc. Telemedicine is an information technology that enables doctors to perform medical consultations, diagnoses, and treatments, as well as medical education, away from patients. For example, doctors can remotely examine patients via remote viewing monitors and sound devices, and/or sampling physiological data using telecommunication. Telemedicine technology is applied to areas of emergency healthcare, videoconsulting, telecardiology, telepathology, teledermatology, teleophthalmology, teleoncology, telepsychiatry, teledentistry, etc. International Journal of Telemedicine and Applications will highlight the continued growth and new challenges in telemedicine, applications, and their supporting technologies, for both application development and basic research. Papers should emphasize original results or case studies relating to the theory and/or applications of telemedicine. Tutorial papers, especially those emphasizing multidisciplinary views of telemedicine, are also welcome. International Journal of Telemedicine and Applications employs a paperless, electronic submission and evaluation system to promote a rapid turnaround in the peer-review process.