Yingzi Zhen, Di Ai, Kun Huang, Gang Li, Zhenping Chen, Runhui Wu
{"title":"The influence of dead space in blood sampling needle on FVIII level and pharmacokinetic profiles in children with hemophilia.","authors":"Yingzi Zhen, Di Ai, Kun Huang, Gang Li, Zhenping Chen, Runhui Wu","doi":"10.1080/16078454.2024.2314871","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the influence of the dead space in disposable blood sampling needle on activated partial thromboplastin time (APTT), FVIII level and pharmacokinetic (PK) profiles in children with hemophilia.</p><p><strong>Methods: </strong>Children (<18 years) with severe hemophilia A were enrolled. After three days' washout-period, blood samples were collected at pre-dose, 1 h, 3 h, 9 h, 24 h and 48 h post-infusion. At each timepoint, two 2 mL vacuum tubes with 3.2% trisodium citrate were used. The first tube was signed as 'non-standard' (NS) and the second tube was signed as 'standard' (S). FVIII activities were evaluated by one-stage assay. WAPPS-Hemo was used to generate PK profiles like half-life time (t<sub>1/2</sub>), clearance (CL), trough level and time to 1, 2 and 5IU/dL after a dose of 50 ± 10IU/dL. The FVIII activities at 9 h and 24 h post-infusion were put into WAPPS and thus brought four combinations by true or biased FVIII level that used.</p><p><strong>Result: </strong>Compared with standard-collected blood samples, prolonged APTT results (<i>P</i>-values < 0.01) and decreased FVIII activity (<i>P</i>-values < 0.05) were revealed in those non-standard blood samples. The corresponding bias was in positive relation to both APTT-S (r = 0.44, <i>P </i>< 0.0001) and FVIII-S level(r = 0.68, <i>P </i>< 0.001). The FVIII bias percentage got larger as FVIII-S level reduced (r = -0.24, <i>P </i>< 0.01). During the four combinations of FVIII activity at 9 h and 24 h, statistically longer t<sub>1/2</sub>, lower CL and longer time to 1, 2 or 5IU/dL were observed in 9H-S&24H-S group and 9H-NS&24H-S group.</p><p><strong>Conclusion: </strong>While using vacuum tubes for clotting indicators and PK profiles, the dead space of blood sampling needle should be eliminated in advance.</p>","PeriodicalId":13161,"journal":{"name":"Hematology","volume":"29 1","pages":"2314871"},"PeriodicalIF":2.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hematology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/16078454.2024.2314871","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To investigate the influence of the dead space in disposable blood sampling needle on activated partial thromboplastin time (APTT), FVIII level and pharmacokinetic (PK) profiles in children with hemophilia.
Methods: Children (<18 years) with severe hemophilia A were enrolled. After three days' washout-period, blood samples were collected at pre-dose, 1 h, 3 h, 9 h, 24 h and 48 h post-infusion. At each timepoint, two 2 mL vacuum tubes with 3.2% trisodium citrate were used. The first tube was signed as 'non-standard' (NS) and the second tube was signed as 'standard' (S). FVIII activities were evaluated by one-stage assay. WAPPS-Hemo was used to generate PK profiles like half-life time (t1/2), clearance (CL), trough level and time to 1, 2 and 5IU/dL after a dose of 50 ± 10IU/dL. The FVIII activities at 9 h and 24 h post-infusion were put into WAPPS and thus brought four combinations by true or biased FVIII level that used.
Result: Compared with standard-collected blood samples, prolonged APTT results (P-values < 0.01) and decreased FVIII activity (P-values < 0.05) were revealed in those non-standard blood samples. The corresponding bias was in positive relation to both APTT-S (r = 0.44, P < 0.0001) and FVIII-S level(r = 0.68, P < 0.001). The FVIII bias percentage got larger as FVIII-S level reduced (r = -0.24, P < 0.01). During the four combinations of FVIII activity at 9 h and 24 h, statistically longer t1/2, lower CL and longer time to 1, 2 or 5IU/dL were observed in 9H-S&24H-S group and 9H-NS&24H-S group.
Conclusion: While using vacuum tubes for clotting indicators and PK profiles, the dead space of blood sampling needle should be eliminated in advance.
期刊介绍:
Hematology is an international journal publishing original and review articles in the field of general hematology, including oncology, pathology, biology, clinical research and epidemiology. Of the fixed sections, annotations are accepted on any general or scientific field: technical annotations covering current laboratory practice in general hematology, blood transfusion and clinical trials, and current clinical practice reviews the consensus driven areas of care and management.