Utilizing Human-Induced Pluripotent Stem Cells to Study Cardiac Electroporation Pulsed-Field Ablation.

IF 9.1 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Leonid Maizels, Eyal Heller, Michal Landesberg, Shany Glatstein, Irit Huber, Gil Arbel, Amira Gepstein, Doron Aronson, Shirley Sharabi, Roy Beinart, Amit Segev, Elad Maor, Lior Gepstein
{"title":"Utilizing Human-Induced Pluripotent Stem Cells to Study Cardiac Electroporation Pulsed-Field Ablation.","authors":"Leonid Maizels, Eyal Heller, Michal Landesberg, Shany Glatstein, Irit Huber, Gil Arbel, Amira Gepstein, Doron Aronson, Shirley Sharabi, Roy Beinart, Amit Segev, Elad Maor, Lior Gepstein","doi":"10.1161/CIRCEP.123.012278","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Electroporation is a promising nonthermal ablation method for cardiac arrhythmia treatment. Although initial clinical studies found electroporation pulsed-field ablation (PFA) both safe and efficacious, there are significant knowledge gaps concerning the mechanistic nature and electrophysiological consequences of cardiomyocyte electroporation, contributed by the paucity of suitable human in vitro models. Here, we aimed to establish and characterize a functional in vitro model based on human-induced pluripotent stem cells (hiPSCs)-derived cardiac tissue, and to study the fundamentals of cardiac PFA.</p><p><strong>Methods: </strong>hiPSC-derived cardiomyocytes were seeded as circular cell sheets and subjected to different PFA protocols. Detailed optical mapping, cellular, and molecular characterizations were performed to study PFA mechanisms and electrophysiological outcomes.</p><p><strong>Results: </strong>PFA generated electrically silenced lesions within the hiPSC-derived cardiac circular cell sheets, resulting in areas of conduction block. Both reversible and irreversible electroporation components were identified. Significant electroporation reversibility was documented within 5 to 15-minutes post-PFA. Irreversibly electroporated regions persisted at 24-hours post-PFA. Per single pulse, high-frequency PFA was less efficacious than standard (monophasic) PFA, whereas increasing pulse-number augmented lesion size and diminished reversible electroporation. PFA augmentation could also be achieved by increasing extracellular Ca<sup>2+</sup> levels. Flow-cytometry experiments revealed that regulated cell death played an important role following PFA. Assessing for PFA antiarrhythmic properties, sustainable lines of conduction block could be generated using PFA, which could either terminate or isolate arrhythmic activity in the hiPSC-derived cardiac circular cell sheets.</p><p><strong>Conclusions: </strong>Cardiac electroporation may be studied using hiPSC-derived cardiac tissue, providing novel insights into PFA temporal and electrophysiological characteristics, facilitating electroporation protocol optimization, screening for potential PFA-sensitizers, and investigating the mechanistic nature of PFA antiarrhythmic properties.</p>","PeriodicalId":10319,"journal":{"name":"Circulation. Arrhythmia and electrophysiology","volume":" ","pages":"e012278"},"PeriodicalIF":9.1000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10949974/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation. Arrhythmia and electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCEP.123.012278","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Electroporation is a promising nonthermal ablation method for cardiac arrhythmia treatment. Although initial clinical studies found electroporation pulsed-field ablation (PFA) both safe and efficacious, there are significant knowledge gaps concerning the mechanistic nature and electrophysiological consequences of cardiomyocyte electroporation, contributed by the paucity of suitable human in vitro models. Here, we aimed to establish and characterize a functional in vitro model based on human-induced pluripotent stem cells (hiPSCs)-derived cardiac tissue, and to study the fundamentals of cardiac PFA.

Methods: hiPSC-derived cardiomyocytes were seeded as circular cell sheets and subjected to different PFA protocols. Detailed optical mapping, cellular, and molecular characterizations were performed to study PFA mechanisms and electrophysiological outcomes.

Results: PFA generated electrically silenced lesions within the hiPSC-derived cardiac circular cell sheets, resulting in areas of conduction block. Both reversible and irreversible electroporation components were identified. Significant electroporation reversibility was documented within 5 to 15-minutes post-PFA. Irreversibly electroporated regions persisted at 24-hours post-PFA. Per single pulse, high-frequency PFA was less efficacious than standard (monophasic) PFA, whereas increasing pulse-number augmented lesion size and diminished reversible electroporation. PFA augmentation could also be achieved by increasing extracellular Ca2+ levels. Flow-cytometry experiments revealed that regulated cell death played an important role following PFA. Assessing for PFA antiarrhythmic properties, sustainable lines of conduction block could be generated using PFA, which could either terminate or isolate arrhythmic activity in the hiPSC-derived cardiac circular cell sheets.

Conclusions: Cardiac electroporation may be studied using hiPSC-derived cardiac tissue, providing novel insights into PFA temporal and electrophysiological characteristics, facilitating electroporation protocol optimization, screening for potential PFA-sensitizers, and investigating the mechanistic nature of PFA antiarrhythmic properties.

利用人类诱导多能干细胞研究心脏电穿孔脉冲场消融。
背景:电穿孔是治疗心律失常的一种前景广阔的非热消融方法。尽管最初的临床研究发现电穿孔脉冲场消融术(PFA)既安全又有效,但有关心肌细胞电穿孔的机理性质和电生理后果的知识仍有很大差距,而合适的人类体外模型却很少。在此,我们旨在建立一个基于人类诱导多能干细胞(hiPSCs)衍生心脏组织的功能性体外模型,并对其进行表征,同时研究心脏PFA的基本原理。方法:将 hiPSC 衍生的心肌细胞播种成圆形细胞片,并对其进行不同的 PFA 处理,然后进行详细的光学绘图、细胞和分子表征,以研究 PFA 机制和电生理结果:结果:PFA 在 hiPSC 衍生的心脏圆形细胞片中产生了电沉默病变,导致传导阻滞区域。可逆和不可逆电穿孔成分均已确定。电穿孔后 5 至 15 分钟内记录到明显的电穿孔可逆性。不可逆电穿孔区域在 PFA 术后 24 小时仍然存在。与标准(单相)PFA 相比,单脉冲高频 PFA 的疗效较差,而脉冲数的增加会增大病变面积并减弱可逆电穿孔。增加细胞外 Ca2+ 水平也能增强 PFA。流式细胞术实验表明,PFA 作用下的细胞死亡调节起着重要作用。在评估 PFA 抗心律失常特性时,可使用 PFA 生成可持续的电阻滞线,从而终止或隔离 hiPSC 衍生的心脏圆形细胞片中的心律失常活动:结论:可利用 hiPSC 衍生的心脏组织研究心脏电穿孔,同时提供有关 PFA 时间和电生理特性的新见解,促进电穿孔方案优化、筛选潜在的 PFA 增敏剂以及研究 PFA 抗心律失常特性的机理本质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
13.70
自引率
4.80%
发文量
187
审稿时长
4-8 weeks
期刊介绍: Circulation: Arrhythmia and Electrophysiology is a journal dedicated to the study and application of clinical cardiac electrophysiology. It covers a wide range of topics including the diagnosis and treatment of cardiac arrhythmias, as well as research in this field. The journal accepts various types of studies, including observational research, clinical trials, epidemiological studies, and advancements in translational research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信