{"title":"Evaluation of attenuation correction method for head holder in brain perfusion single-photon emission computed tomography.","authors":"Masahiro Nakashima, Yuta Yamazaki","doi":"10.1007/s12194-024-00778-x","DOIUrl":null,"url":null,"abstract":"<p><p>Head holder attenuation affects brain perfusion single-photon emission computed tomography (SPECT) image quality. Here, we proposed a head holder-attenuation correction (AC) method using attenuation coefficient maps calculated by Chang's method from CT images. Then, we evaluated the effectiveness of the head holder-AC method by numerical phantom and clinical cerebral perfusion SPECT studies. In the numerical phantom, the posterior counts were 10.7% lower than the anterior counts without head holder-AC method. However, by performing head holder-AC, the posterior count recovered by approximately 6.8%, approaching the true value. In the clinical study, the normalized count ratio was significantly increased by performing the head holder-AC method in the posterior-middle cerebral artery, posterior cerebral artery and cerebellum regions. There were no significant increases in other regions. The head holder-AC method can correct the counts attenuated by the head holder.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-024-00778-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Head holder attenuation affects brain perfusion single-photon emission computed tomography (SPECT) image quality. Here, we proposed a head holder-attenuation correction (AC) method using attenuation coefficient maps calculated by Chang's method from CT images. Then, we evaluated the effectiveness of the head holder-AC method by numerical phantom and clinical cerebral perfusion SPECT studies. In the numerical phantom, the posterior counts were 10.7% lower than the anterior counts without head holder-AC method. However, by performing head holder-AC, the posterior count recovered by approximately 6.8%, approaching the true value. In the clinical study, the normalized count ratio was significantly increased by performing the head holder-AC method in the posterior-middle cerebral artery, posterior cerebral artery and cerebellum regions. There were no significant increases in other regions. The head holder-AC method can correct the counts attenuated by the head holder.
期刊介绍:
The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.