Femoral Component Design Is Associated With the Risk of Periprosthetic Femur Fracture After Cementless THA in Patients 65 Years or Older.

IF 4.2 2区 医学 Q1 ORTHOPEDICS
Mackenzie Kelly, Antonia F Chen, Sean P Ryan, Zachary M Working, Ayushmita De, Kyle Mullen, Kimberly R Porter, Ryland Kagan
{"title":"Femoral Component Design Is Associated With the Risk of Periprosthetic Femur Fracture After Cementless THA in Patients 65 Years or Older.","authors":"Mackenzie Kelly, Antonia F Chen, Sean P Ryan, Zachary M Working, Ayushmita De, Kyle Mullen, Kimberly R Porter, Ryland Kagan","doi":"10.1097/CORR.0000000000002985","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Periprosthetic femur fracture is a known complication after THA. The associated risk of cementless femoral component design for periprosthetic femur fracture in a registry population of patients older than 65 years has yet to be clearly identified.</p><p><strong>Questions/purposes: </strong>(1) Is femoral stem geometry associated with the risk of periprosthetic femur fracture after cementless THA? (2) Is the presence or absence of a collar on cementless femoral implant designs associated with the risk of periprosthetic femur fracture after THA?</p><p><strong>Methods: </strong>We analyzed American Joint Replacement Registry data from 2012 to March 2020. Unique to this registry is the high use of cementless femoral stems in patients 65 years and older. We identified 266,040 primary cementless THAs during the study period in patients with a diagnosis of osteoarthritis and surgeries linked to supplemental Centers for Medicare and Medicaid data where available. Patient demographics, procedure dates, and reoperation for periprosthetic femur fracture with revision or open reduction and internal fixation were recorded. The main analysis was performed comparing the Kheir and Chen classification: 42% (112,231 of 266,040) were single-wedge, 22% (57,758 of 266,040) were double-wedge, and 24% (62,983 of 266,040) were gradual taper/metadiaphyseal-filling cementless femoral components, which yielded a total of 232,972 primary cementless THAs. An additional analysis compared cementless stems with collars (20% [47,376 of 232,972]) with those with collarless designs (80% [185,596 of 232,972]). A Cox proportional hazard regression analysis with the competing risk of death was used to evaluate the association of design and fracture risk while adjusting for potential confounders.</p><p><strong>Results: </strong>After controlling for the potentially confounding variables of age, sex, geographic region, osteoporosis or osteopenia diagnosis, hospital volume, and the competing risk of death, we found that compared with gradual taper/metadiaphyseal-filling stems, single-wedge designs were associated with a greater risk of periprosthetic femur fracture (HR 2.9 [95% confidence interval (CI) 2.2 to 3.9]; p < 0. 001). Compared with gradual taper/metadiaphyseal-filling stems, double-wedge designs showed an increased risk of periprosthetic femur fracture (HR 3.0 [95% CI 2.2 to 4.0]; p < 0. 001). Collarless stems showed an increased risk of periprosthetic fracture compared with collared stems (HR 7.8 [95% CI 4.1 to 15]; p < 0. 001).</p><p><strong>Conclusion: </strong>If cementless femoral fixation is used for THA in patients 65 years or older, surgeons should consider using gradual taper/metadiaphyseal-filling and collared stem designs because they are associated with a lower risk of periprosthetic femur fracture. Future investigations should compare gradual taper/metadiaphyseal-filling and collared cementless designs with cemented fixation in this population.</p><p><strong>Level of evidence: </strong>Level III, therapeutic study.</p>","PeriodicalId":10404,"journal":{"name":"Clinical Orthopaedics and Related Research®","volume":null,"pages":null},"PeriodicalIF":4.2000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11272275/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Orthopaedics and Related Research®","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/CORR.0000000000002985","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Periprosthetic femur fracture is a known complication after THA. The associated risk of cementless femoral component design for periprosthetic femur fracture in a registry population of patients older than 65 years has yet to be clearly identified.

Questions/purposes: (1) Is femoral stem geometry associated with the risk of periprosthetic femur fracture after cementless THA? (2) Is the presence or absence of a collar on cementless femoral implant designs associated with the risk of periprosthetic femur fracture after THA?

Methods: We analyzed American Joint Replacement Registry data from 2012 to March 2020. Unique to this registry is the high use of cementless femoral stems in patients 65 years and older. We identified 266,040 primary cementless THAs during the study period in patients with a diagnosis of osteoarthritis and surgeries linked to supplemental Centers for Medicare and Medicaid data where available. Patient demographics, procedure dates, and reoperation for periprosthetic femur fracture with revision or open reduction and internal fixation were recorded. The main analysis was performed comparing the Kheir and Chen classification: 42% (112,231 of 266,040) were single-wedge, 22% (57,758 of 266,040) were double-wedge, and 24% (62,983 of 266,040) were gradual taper/metadiaphyseal-filling cementless femoral components, which yielded a total of 232,972 primary cementless THAs. An additional analysis compared cementless stems with collars (20% [47,376 of 232,972]) with those with collarless designs (80% [185,596 of 232,972]). A Cox proportional hazard regression analysis with the competing risk of death was used to evaluate the association of design and fracture risk while adjusting for potential confounders.

Results: After controlling for the potentially confounding variables of age, sex, geographic region, osteoporosis or osteopenia diagnosis, hospital volume, and the competing risk of death, we found that compared with gradual taper/metadiaphyseal-filling stems, single-wedge designs were associated with a greater risk of periprosthetic femur fracture (HR 2.9 [95% confidence interval (CI) 2.2 to 3.9]; p < 0. 001). Compared with gradual taper/metadiaphyseal-filling stems, double-wedge designs showed an increased risk of periprosthetic femur fracture (HR 3.0 [95% CI 2.2 to 4.0]; p < 0. 001). Collarless stems showed an increased risk of periprosthetic fracture compared with collared stems (HR 7.8 [95% CI 4.1 to 15]; p < 0. 001).

Conclusion: If cementless femoral fixation is used for THA in patients 65 years or older, surgeons should consider using gradual taper/metadiaphyseal-filling and collared stem designs because they are associated with a lower risk of periprosthetic femur fracture. Future investigations should compare gradual taper/metadiaphyseal-filling and collared cementless designs with cemented fixation in this population.

Level of evidence: Level III, therapeutic study.

股骨组件设计与65岁及以上患者接受无骨水泥全髋关节置换术后发生假体周围股骨骨折的风险有关。
背景:股骨假体周围骨折是THA术后的一种已知并发症。问题/目的:(1) 无骨水泥THA术后股骨柄几何形状与股骨假体周围骨折的风险是否相关? (2) 无骨水泥股骨植入物设计上有无套环与THA术后股骨假体周围骨折的风险是否相关?我们分析了美国关节置换登记处 2012 年至 2020 年 3 月的数据。该登记处的独特之处在于无骨水泥股骨柄在 65 岁及以上患者中的高使用率。在研究期间,我们确定了 266,040 例诊断为骨关节炎的患者的初次无骨水泥 THAs,以及与医疗保险和医疗补助中心补充数据(如有)相关联的手术。研究记录了患者的人口统计学特征、手术日期以及股骨假体周围骨折翻修或切开复位和内固定的再手术情况。主要分析比较了Kheir和Chen分类法:42%(266,040例中的112,231例)为单楔式,22%(266,040例中的57,758例)为双楔式,24%(266,040例中的62,983例)为渐变锥度/骨干填充式无骨水泥股骨组件,共计232,972例初次无骨水泥THA。另外一项分析比较了有套环的无骨水泥柄(20% [232,972例中的47,376例])和无套环设计的无骨水泥柄(80% [232,972例中的185,596例])。在对潜在的混杂因素进行调整的同时,采用了死亡风险竞争的 Cox 比例危险回归分析来评估设计与骨折风险之间的关系:结果:在控制了年龄、性别、地理区域、骨质疏松症或骨质增生诊断、住院量和死亡竞争风险等潜在混杂变量后,我们发现与渐进锥形/骺端填充柄相比,单楔设计与股骨假体周围骨折的风险更大相关(HR 2.9 [95% 置信区间 (CI) 2.2 to 3.9]; p < 0. 001)。与逐渐变细/骺端填充柄相比,双刃设计显示股骨假体周围骨折的风险增加(HR 3.0 [95% CI 2.2 至 4.0];P < 0. 001)。与有袢股骨柄相比,无袢股骨柄发生假体周围骨折的风险更高(HR 7.8 [95% CI 4.1 to 15];P < 0.001):如果在65岁或以上患者的THA中使用无骨水泥股骨固定,外科医生应考虑使用渐进锥度/骺端填充和有袢柄设计,因为它们与较低的股骨假体周围骨折风险相关。未来的研究应在这一人群中比较渐进锥形/金属骺填充和有骨袢无骨水泥设计与骨水泥固定:证据等级:III级,治疗性研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.00
自引率
11.90%
发文量
722
审稿时长
2.5 months
期刊介绍: Clinical Orthopaedics and Related Research® is a leading peer-reviewed journal devoted to the dissemination of new and important orthopaedic knowledge. CORR® brings readers the latest clinical and basic research, along with columns, commentaries, and interviews with authors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信