Hirokazu Wakuda, Yue Xiang, Jasleen K Sodhi, Naoto Uemura, Leslie Z Benet
{"title":"An Explanation of Why Dose-Corrected Area Under the Curve for Alternate Administration Routes Can Be Greater than for Intravenous Dosing.","authors":"Hirokazu Wakuda, Yue Xiang, Jasleen K Sodhi, Naoto Uemura, Leslie Z Benet","doi":"10.1208/s12248-024-00887-w","DOIUrl":null,"url":null,"abstract":"<p><p>It is generally believed that bioavailability (F) calculated based on systemic concentration area under the curve (AUC) measurements cannot exceed 1.0, yet some published studies report this inconsistency. We teach and believe, based on differential equation derivations, that rate of absorption has no influence on measured systemic clearance following an oral dose, i.e., determined as available dose divided by AUC. Previously, it was thought that any difference in calculating F from urine data versus that from systemic concentration AUC data was due to the inability to accurately measure urine data. A PubMed literature search for drugs exhibiting F > 1.0 and studies for which F was measured using both AUC and urinary excretion dose-corrected analyses yielded data for 35 drugs. We show and explain, using Kirchhoff's Laws, that these universally held concepts concerning bioavailability may not be valid in all situations. Bioavailability, determined using systemic concentration measurements, for many drugs may be overestimated since AUC reflects not only systemic elimination but also absorption rate characteristics, which is most easily seen for renal clearance measures. Clearance of drug from the absorption site must be significantly greater than clearance following an iv bolus dose for F(AUC) to correctly correspond with F(urine). The primary purpose of this paper is to demonstrate that studies resulting in F > 1.0 and/or greater systemic vs urine bioavailability predictions may be accurate. Importantly, these explications have no significant impact on current regulatory guidance for bioequivalence testing, nor on the use of exposure (AUC) measures in making drug dosing decisions.</p>","PeriodicalId":50934,"journal":{"name":"AAPS Journal","volume":"26 1","pages":"22"},"PeriodicalIF":5.0000,"publicationDate":"2024-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AAPS Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1208/s12248-024-00887-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
Abstract
It is generally believed that bioavailability (F) calculated based on systemic concentration area under the curve (AUC) measurements cannot exceed 1.0, yet some published studies report this inconsistency. We teach and believe, based on differential equation derivations, that rate of absorption has no influence on measured systemic clearance following an oral dose, i.e., determined as available dose divided by AUC. Previously, it was thought that any difference in calculating F from urine data versus that from systemic concentration AUC data was due to the inability to accurately measure urine data. A PubMed literature search for drugs exhibiting F > 1.0 and studies for which F was measured using both AUC and urinary excretion dose-corrected analyses yielded data for 35 drugs. We show and explain, using Kirchhoff's Laws, that these universally held concepts concerning bioavailability may not be valid in all situations. Bioavailability, determined using systemic concentration measurements, for many drugs may be overestimated since AUC reflects not only systemic elimination but also absorption rate characteristics, which is most easily seen for renal clearance measures. Clearance of drug from the absorption site must be significantly greater than clearance following an iv bolus dose for F(AUC) to correctly correspond with F(urine). The primary purpose of this paper is to demonstrate that studies resulting in F > 1.0 and/or greater systemic vs urine bioavailability predictions may be accurate. Importantly, these explications have no significant impact on current regulatory guidance for bioequivalence testing, nor on the use of exposure (AUC) measures in making drug dosing decisions.
期刊介绍:
The AAPS Journal, an official journal of the American Association of Pharmaceutical Scientists (AAPS), publishes novel and significant findings in the various areas of pharmaceutical sciences impacting human and veterinary therapeutics, including:
· Drug Design and Discovery
· Pharmaceutical Biotechnology
· Biopharmaceutics, Formulation, and Drug Delivery
· Metabolism and Transport
· Pharmacokinetics, Pharmacodynamics, and Pharmacometrics
· Translational Research
· Clinical Evaluations and Therapeutic Outcomes
· Regulatory Science
We invite submissions under the following article types:
· Original Research Articles
· Reviews and Mini-reviews
· White Papers, Commentaries, and Editorials
· Meeting Reports
· Brief/Technical Reports and Rapid Communications
· Regulatory Notes
· Tutorials
· Protocols in the Pharmaceutical Sciences
In addition, The AAPS Journal publishes themes, organized by guest editors, which are focused on particular areas of current interest to our field.