A State Table SPHIT Approach for Modified Curvelet-based Medical Image Compression

N. H. Ja'afar, Afandi Ahmad, S. Safie
{"title":"A State Table SPHIT Approach for Modified Curvelet-based Medical Image Compression","authors":"N. H. Ja'afar, Afandi Ahmad, S. Safie","doi":"10.3991/ijoe.v20i01.41363","DOIUrl":null,"url":null,"abstract":"Medical imaging plays a significant role in clinical practice. Storing and transferring a large volume of images can be complex and inefficient. This paper presents the development of a new compression technique that combines the fast discrete curvelet transform (FDCvT) with state table set partitioning in the hierarchical trees (STS) encoding scheme. The curvelet transform is an extension of the wavelet transform algorithm that represents data based on scale and position. Initially, the medical image was decomposed using the FDCvT algorithm. The FDCvT algorithm creates symmetrical values for the detail coefficients, and these coefficients are modified to improve the efficiency of the algorithm. The curvelet coefficients are then encoded using the STS and differential pulse-code modulation (DPCM). The greatest amount of energy is contained in the coarse coefficients, which are encoded using the DPCM method. The finest and modified detail coefficients are encoded using the STS method. A variety of medical modalities, including computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI), are used to verify the performance of the proposed technique. Various quality metrics, including peak signal-to-noise ratio (PSNR), compression ratio (CR), and structural similarity index (SSIM), are used to evaluate the compression results. Additionally, the computation time for the encoding (ET) and decoding (DT) processes is measured. The experimental results showed that the PET image obtained higher values of the PSNR and CR. The CT image provides high quality for the reconstructed image, with an SSIM value of 0.96 and the fastest ET of 0.13 seconds. The MRI image has the shortest DT, which is 0.23 seconds.","PeriodicalId":507997,"journal":{"name":"International Journal of Online and Biomedical Engineering (iJOE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Online and Biomedical Engineering (iJOE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3991/ijoe.v20i01.41363","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Medical imaging plays a significant role in clinical practice. Storing and transferring a large volume of images can be complex and inefficient. This paper presents the development of a new compression technique that combines the fast discrete curvelet transform (FDCvT) with state table set partitioning in the hierarchical trees (STS) encoding scheme. The curvelet transform is an extension of the wavelet transform algorithm that represents data based on scale and position. Initially, the medical image was decomposed using the FDCvT algorithm. The FDCvT algorithm creates symmetrical values for the detail coefficients, and these coefficients are modified to improve the efficiency of the algorithm. The curvelet coefficients are then encoded using the STS and differential pulse-code modulation (DPCM). The greatest amount of energy is contained in the coarse coefficients, which are encoded using the DPCM method. The finest and modified detail coefficients are encoded using the STS method. A variety of medical modalities, including computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI), are used to verify the performance of the proposed technique. Various quality metrics, including peak signal-to-noise ratio (PSNR), compression ratio (CR), and structural similarity index (SSIM), are used to evaluate the compression results. Additionally, the computation time for the encoding (ET) and decoding (DT) processes is measured. The experimental results showed that the PET image obtained higher values of the PSNR and CR. The CT image provides high quality for the reconstructed image, with an SSIM value of 0.96 and the fastest ET of 0.13 seconds. The MRI image has the shortest DT, which is 0.23 seconds.
基于修正曲线的医学图像压缩的状态表 SPHIT 方法
医学成像在临床实践中发挥着重要作用。存储和传输大量图像可能既复杂又低效。本文介绍了一种新的压缩技术,它将快速离散小曲线变换(FDCvT)与分层树(STS)编码方案中的状态表集分割相结合。小曲线变换是小波变换算法的扩展,它根据尺度和位置来表示数据。最初,医学影像采用 FDCvT 算法进行分解。FDCvT 算法为细节系数创建对称值,并对这些系数进行修改,以提高算法的效率。然后使用 STS 和差分脉冲编码调制 (DPCM) 对 curvelet 系数进行编码。粗系数包含的能量最大,采用 DPCM 方法对其进行编码。最精细和经过修改的细节系数则使用 STS 方法进行编码。包括计算机断层扫描 (CT)、正电子发射断层扫描 (PET) 和磁共振成像 (MRI) 在内的各种医疗模式都被用来验证所提技术的性能。各种质量指标,包括峰值信噪比(PSNR)、压缩比(CR)和结构相似性指数(SSIM),都被用来评估压缩结果。此外,还测量了编码(ET)和解码(DT)过程的计算时间。实验结果表明,PET 图像获得了较高的 PSNR 值和 CR 值。CT 图像的重建图像质量较高,SSIM 值为 0.96,最快的 ET 为 0.13 秒。MRI 图像的 DT 最短,为 0.23 秒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信