A study on Analysing the Selection of Materials for Knee Implant Femoral Components using the TOPSIS method

4 Pub Date : 2024-01-19 DOI:10.46632/jame/2/4/01
{"title":"A study on Analysing the Selection of Materials for Knee Implant Femoral Components using the TOPSIS method","authors":"","doi":"10.46632/jame/2/4/01","DOIUrl":null,"url":null,"abstract":"Specialists are creating more sophisticated and useful materials daily as technology advances. For orthopaedic implants such as \"knee replacements, hip replacements, and orthopaedic accessories\", biomaterials are employed to produce prosthetic organs. In patients with severe osteoarthritis (OA) of the knee, \"total knee replacement (TKR)\" is one of the most successful surgical procedures for pain management and functioning rehabilitation. Humans continue to experience issues with the kneecap, such as aseptic dislocation brought on by excessive wear across articular surfaces, stress-shielding of the bone by prostheses, and soft tissue formation at the junction of implanted bone. due to improper “TKR material selection”. Since selecting the best materials for the femoral component of TKR requires careful consideration, the \"technique for order of preference by similarity to ideal solution (TOPSIS)\" is used in this research paper. This technique uses an order of preference based on how closely the preferred option is to the ideal solution. The \"equal weights method (EWM)\" assigns various criteria distinct weights of importance. The rank of alternatives using the TOPSIS method for “Co-Cr-Mo is fourth, Co-Ni-Cr-Mo is third, NiTi SMA is first, Porous NiTi SMA is second, pure Ti is sixth and Ti-5Al-2.5Fe is fifth”. The result indicated that FC material using TKR Nickel Titanium Shape Memory Alloy (NiTi SMA) is at rank 1 with properties such as Tensile Strength 960 MPa, Density 6.45 g/cc, extremely high Corrosion resistance, and exceptionally high Wear resistance.","PeriodicalId":505677,"journal":{"name":"4","volume":"80 13","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"4","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46632/jame/2/4/01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Specialists are creating more sophisticated and useful materials daily as technology advances. For orthopaedic implants such as "knee replacements, hip replacements, and orthopaedic accessories", biomaterials are employed to produce prosthetic organs. In patients with severe osteoarthritis (OA) of the knee, "total knee replacement (TKR)" is one of the most successful surgical procedures for pain management and functioning rehabilitation. Humans continue to experience issues with the kneecap, such as aseptic dislocation brought on by excessive wear across articular surfaces, stress-shielding of the bone by prostheses, and soft tissue formation at the junction of implanted bone. due to improper “TKR material selection”. Since selecting the best materials for the femoral component of TKR requires careful consideration, the "technique for order of preference by similarity to ideal solution (TOPSIS)" is used in this research paper. This technique uses an order of preference based on how closely the preferred option is to the ideal solution. The "equal weights method (EWM)" assigns various criteria distinct weights of importance. The rank of alternatives using the TOPSIS method for “Co-Cr-Mo is fourth, Co-Ni-Cr-Mo is third, NiTi SMA is first, Porous NiTi SMA is second, pure Ti is sixth and Ti-5Al-2.5Fe is fifth”. The result indicated that FC material using TKR Nickel Titanium Shape Memory Alloy (NiTi SMA) is at rank 1 with properties such as Tensile Strength 960 MPa, Density 6.45 g/cc, extremely high Corrosion resistance, and exceptionally high Wear resistance.
关于使用 TOPSIS 方法分析膝关节假体股骨组件材料选择的研究
随着技术的进步,专家们每天都在创造出更复杂、更有用的材料。在 "膝关节置换术、髋关节置换术和骨科配件 "等骨科植入物方面,生物材料被用来制造假体器官。对于患有严重膝关节骨性关节炎(OA)的患者,"全膝关节置换术(TKR)"是治疗疼痛和功能康复最成功的外科手术之一。由于 "全膝关节置换术(TKR)材料选择 "不当,人类的膝盖骨仍然存在问题,如关节面过度磨损导致的无菌性脱位、假体对骨的应力屏蔽以及植入骨交界处软组织的形成。由于选择 TKR 股骨组件的最佳材料需要慎重考虑,本研究论文采用了 "与理想解相似度排序技术(TOPSIS)"。该技术根据首选方案与理想方案的接近程度来排序。等权法(EWM)"赋予各种标准不同的重要性权重。使用 TOPSIS 方法得出的备选方案排名为:"Co-Cr-Mo 第四,Co-Ni-Cr-Mo 第三,NiTi SMA 第一,多孔 NiTi SMA 第二,纯 Ti 第六,Ti-5Al-2.5Fe 第五"。结果表明,使用 TKR 镍钛形状记忆合金(NiTi SMA)的 FC 材料排名第一,其性能包括拉伸强度 960 兆帕、密度 6.45 克/立方厘米、极高的耐腐蚀性和极高的耐磨性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
4
4
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信