The Complication and Safety Profile of Utilizing Kirschner Wires in Four Corner Fusions

Pub Date : 2024-01-25 DOI:10.1055/s-0043-1778084
Shelby R. Smith, Karan Dua, R. Wysocki, John J. Fernandez, Mark S. Cohen, Xavier C. Simcock
{"title":"The Complication and Safety Profile of Utilizing Kirschner Wires in Four Corner Fusions","authors":"Shelby R. Smith, Karan Dua, R. Wysocki, John J. Fernandez, Mark S. Cohen, Xavier C. Simcock","doi":"10.1055/s-0043-1778084","DOIUrl":null,"url":null,"abstract":"\n Background Four corner fusion (4CF) can be performed using various techniques, each with its own efficacy and complication profile. Kirschner wires (K-wires) are a reliable and cost-effective method when performing 4CF.\n Purpose The purpose of this study was to determine the union rate and complication profile of utilizing K-wires when performing a 4CF.\n Methods A retrospective chart review was performed studying patients who underwent 4CF from a multisurgeon, single-institution database. Demographic data were collected, and functional outcomes were recorded including wrist range of motion (ROM), fusion rates, time to fusion, and complication rates. Continuous variables were compared via two-tailed t-tests, numerical data via one-way analysis of variance tests, and categorical data via Fisher's Exact test.\n Results In total, 141 patients underwent 4CF with K-wire fixation with an overall nonunion rate of 3.5% (5/141). Diabetics had a nonunion rate of 11% compared to 3% without diabetes (p = 0.28). Wrist ROM was significantly greater in patients who achieved bony union at 6 weeks after removal of hardware compared to the nonunion group (78.0 degrees ± 14.4 vs. 57.8 degrees ± 21.3, p < 0.05). There was no difference in wrist ROM between the two groups six months after hardware removal. There were no pin-related complications that required revision surgery.\n Conclusion 4CF utilizing K-wire fixation is a reproducible and cost-effective technique that results in good patient outcomes including bony union and functional wrist ROM. Smoking and diabetes did not significantly increase the risk of nonunion, and K-wire fixation can successfully be used in these patient populations.\n Level of Evidence Level IV (retrospective study)","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1778084","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background Four corner fusion (4CF) can be performed using various techniques, each with its own efficacy and complication profile. Kirschner wires (K-wires) are a reliable and cost-effective method when performing 4CF. Purpose The purpose of this study was to determine the union rate and complication profile of utilizing K-wires when performing a 4CF. Methods A retrospective chart review was performed studying patients who underwent 4CF from a multisurgeon, single-institution database. Demographic data were collected, and functional outcomes were recorded including wrist range of motion (ROM), fusion rates, time to fusion, and complication rates. Continuous variables were compared via two-tailed t-tests, numerical data via one-way analysis of variance tests, and categorical data via Fisher's Exact test. Results In total, 141 patients underwent 4CF with K-wire fixation with an overall nonunion rate of 3.5% (5/141). Diabetics had a nonunion rate of 11% compared to 3% without diabetes (p = 0.28). Wrist ROM was significantly greater in patients who achieved bony union at 6 weeks after removal of hardware compared to the nonunion group (78.0 degrees ± 14.4 vs. 57.8 degrees ± 21.3, p < 0.05). There was no difference in wrist ROM between the two groups six months after hardware removal. There were no pin-related complications that required revision surgery. Conclusion 4CF utilizing K-wire fixation is a reproducible and cost-effective technique that results in good patient outcomes including bony union and functional wrist ROM. Smoking and diabetes did not significantly increase the risk of nonunion, and K-wire fixation can successfully be used in these patient populations. Level of Evidence Level IV (retrospective study)
分享
查看原文
在四角融合术中使用 Kirschner 线的并发症和安全性概况
背景四角融合术(4CF)可采用多种技术,每种技术都有各自的疗效和并发症情况。Kirschner钢丝(K-wires)是一种可靠且经济有效的四角融合方法。目的 本研究旨在确定使用 K 线进行 4CF 时的结合率和并发症情况。方法 对一个多外科医师、单一机构数据库中接受 4CF 手术的患者进行回顾性病历审查。研究人员收集了人口统计学数据,并记录了功能结果,包括腕关节活动范围(ROM)、融合率、融合时间和并发症发生率。连续变量通过双尾 t 检验进行比较,数字数据通过单因子方差分析检验进行比较,分类数据通过费雪精确检验进行比较。结果 共有141名患者接受了K线固定的4CF手术,总的不愈合率为3.5%(5/141)。糖尿病患者的不愈合率为11%,而非糖尿病患者的不愈合率为3%(P = 0.28)。与未愈合组相比,移除硬件后6周达到骨性愈合的患者的腕关节活动度明显更大(78.0度±14.4比57.8度±21.3,P <0.05)。两组患者在移除硬件6个月后的腕关节活动度没有差异。没有需要进行翻修手术的针相关并发症。结论 利用K线固定的4CF是一种可重复性好、成本效益高的技术,能为患者带来良好的疗效,包括骨性结合和功能性腕关节ROM。吸烟和糖尿病并不会明显增加骨不连的风险,K线固定可成功用于这些患者。证据等级 IV 级(回顾性研究)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信