Ni’meh Al-Shami, Hani Naseef, Ramzi Moqadi, Feras Kanaze
{"title":"HPLC Method Development and Validation for the Determination of Apixaban and Clopidogrel in Novel Fixed-Dose Combination Tablets","authors":"Ni’meh Al-Shami, Hani Naseef, Ramzi Moqadi, Feras Kanaze","doi":"10.1155/2024/2675736","DOIUrl":null,"url":null,"abstract":"A simple, fast, and accurate high-performance liquid chromatographic (HPLC) method is developed, optimized, and validated for a fixed-dose combination of apixaban (APX) and clopidogrel (CLOP) tablets according to ICH guidelines. Chromatographic separation of the drugs was performed on a BDS Hypersil C<sub>18</sub> (4.6 <svg height=\"6.01072pt\" style=\"vertical-align:-0.04980993pt\" version=\"1.1\" viewbox=\"-0.0498162 -5.96091 7.75925 6.01072\" width=\"7.75925pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"></path></g></svg> 150 mm, 5 <i>μ</i>m), with acetonitrile (ACN) and trifluoroacetic acid (TFA) in the ratio 48 : 52 (v/v) as a mobile phase, at a flow rate of 0.9 ml/min., injection volume of 5 <i>μ</i>L, and column temperature 45°C. The proposed method was linear over the level 25–200% for a concentration of APX 5 <i>μ</i>g/ml and CLOP 75 <i>μ</i>g/ml (<i>R</i><sup>2</sup> > 0.999). The detection limit for APX and CLOP was found to be 0.3465 and 3.8496 <i>μ</i>g/ml, whereas the quantification limit was 1.0499 and 11.6656 <i>μ</i>g/ml, respectively. The recovery was more than 99% using the standard addition method. The developed method was found to be specific, accurate, precise, and robust against changes in column temperature (±5°C) and mobile phase composition (±5% ACN); hence, it can be used for the determination of APX and CLOP in the fixed-dose combination tablets.","PeriodicalId":15348,"journal":{"name":"Journal of Chemistry","volume":"54 1","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1155/2024/2675736","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
A simple, fast, and accurate high-performance liquid chromatographic (HPLC) method is developed, optimized, and validated for a fixed-dose combination of apixaban (APX) and clopidogrel (CLOP) tablets according to ICH guidelines. Chromatographic separation of the drugs was performed on a BDS Hypersil C18 (4.6 150 mm, 5 μm), with acetonitrile (ACN) and trifluoroacetic acid (TFA) in the ratio 48 : 52 (v/v) as a mobile phase, at a flow rate of 0.9 ml/min., injection volume of 5 μL, and column temperature 45°C. The proposed method was linear over the level 25–200% for a concentration of APX 5 μg/ml and CLOP 75 μg/ml (R2 > 0.999). The detection limit for APX and CLOP was found to be 0.3465 and 3.8496 μg/ml, whereas the quantification limit was 1.0499 and 11.6656 μg/ml, respectively. The recovery was more than 99% using the standard addition method. The developed method was found to be specific, accurate, precise, and robust against changes in column temperature (±5°C) and mobile phase composition (±5% ACN); hence, it can be used for the determination of APX and CLOP in the fixed-dose combination tablets.
期刊介绍:
Journal of Chemistry is a peer-reviewed, Open Access journal that publishes original research articles as well as review articles in all areas of chemistry.