HPLC Method Development and Validation for the Determination of Apixaban and Clopidogrel in Novel Fixed-Dose Combination Tablets

IF 2.8 4区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY
Ni’meh Al-Shami, Hani Naseef, Ramzi Moqadi, Feras Kanaze
{"title":"HPLC Method Development and Validation for the Determination of Apixaban and Clopidogrel in Novel Fixed-Dose Combination Tablets","authors":"Ni’meh Al-Shami, Hani Naseef, Ramzi Moqadi, Feras Kanaze","doi":"10.1155/2024/2675736","DOIUrl":null,"url":null,"abstract":"A simple, fast, and accurate high-performance liquid chromatographic (HPLC) method is developed, optimized, and validated for a fixed-dose combination of apixaban (APX) and clopidogrel (CLOP) tablets according to ICH guidelines. Chromatographic separation of the drugs was performed on a BDS Hypersil C<sub>18</sub> (4.6 <svg height=\"6.01072pt\" style=\"vertical-align:-0.04980993pt\" version=\"1.1\" viewbox=\"-0.0498162 -5.96091 7.75925 6.01072\" width=\"7.75925pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"></path></g></svg> 150 mm, 5 <i>μ</i>m), with acetonitrile (ACN) and trifluoroacetic acid (TFA) in the ratio 48 : 52 (v/v) as a mobile phase, at a flow rate of 0.9 ml/min., injection volume of 5 <i>μ</i>L, and column temperature 45°C. The proposed method was linear over the level 25–200% for a concentration of APX 5 <i>μ</i>g/ml and CLOP 75 <i>μ</i>g/ml (<i>R</i><sup>2</sup> &gt; 0.999). The detection limit for APX and CLOP was found to be 0.3465 and 3.8496 <i>μ</i>g/ml, whereas the quantification limit was 1.0499 and 11.6656 <i>μ</i>g/ml, respectively. The recovery was more than 99% using the standard addition method. The developed method was found to be specific, accurate, precise, and robust against changes in column temperature (±5°C) and mobile phase composition (±5% ACN); hence, it can be used for the determination of APX and CLOP in the fixed-dose combination tablets.","PeriodicalId":15348,"journal":{"name":"Journal of Chemistry","volume":"54 1","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1155/2024/2675736","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

A simple, fast, and accurate high-performance liquid chromatographic (HPLC) method is developed, optimized, and validated for a fixed-dose combination of apixaban (APX) and clopidogrel (CLOP) tablets according to ICH guidelines. Chromatographic separation of the drugs was performed on a BDS Hypersil C18 (4.6  150 mm, 5 μm), with acetonitrile (ACN) and trifluoroacetic acid (TFA) in the ratio 48 : 52 (v/v) as a mobile phase, at a flow rate of 0.9 ml/min., injection volume of 5 μL, and column temperature 45°C. The proposed method was linear over the level 25–200% for a concentration of APX 5 μg/ml and CLOP 75 μg/ml (R2 > 0.999). The detection limit for APX and CLOP was found to be 0.3465 and 3.8496 μg/ml, whereas the quantification limit was 1.0499 and 11.6656 μg/ml, respectively. The recovery was more than 99% using the standard addition method. The developed method was found to be specific, accurate, precise, and robust against changes in column temperature (±5°C) and mobile phase composition (±5% ACN); hence, it can be used for the determination of APX and CLOP in the fixed-dose combination tablets.
用于测定新型固定剂量复方片剂中阿哌沙班和氯吡格雷的高效液相色谱方法开发与验证
根据 ICH 指南,针对阿哌沙班(APX)和氯吡格雷(CLOP)片剂的固定剂量复方制剂,开发、优化并验证了一种简单、快速、准确的高效液相色谱(HPLC)方法。药物的色谱分离采用 BDS Hypersil C18(4.6 150 mm,5 μm),乙腈(ACN)和三氟乙酸(TFA)的比例为 48 :流动相为乙腈(ACN)和三氟乙酸(TFA),流速为 0.9 ml/min,进样量为 5 μL,柱温为 45°C。当 APX 浓度为 5 μg/ml 和 CLOP 浓度为 75 μg/ml 时,该方法的线性范围为 25%-200%(R2 > 0.999)。APX 和 CLOP 的检测限分别为 0.3465 和 3.8496 μg/ml,而定量限分别为 1.0499 和 11.6656 μg/ml。采用标准添加法,回收率超过 99%。所建立的方法特异、准确、精密,对柱温(±5°C)和流动相组成(±5% ACN)的变化具有良好的稳定性,因此可用于固定剂量复方片剂中APX和CLOP的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Chemistry
Journal of Chemistry CHEMISTRY, MULTIDISCIPLINARY-
CiteScore
5.90
自引率
3.30%
发文量
345
审稿时长
16 weeks
期刊介绍: Journal of Chemistry is a peer-reviewed, Open Access journal that publishes original research articles as well as review articles in all areas of chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信