{"title":"Fiber-Optic Sensor for Identifying Liquids and Determining Solutions Concentration","authors":"A. Zenevich, T. G. Kovalenko, E. Novikov, S. V. Zhdanovich","doi":"10.35596/1729-7648-2023-21-6-14-20","DOIUrl":null,"url":null,"abstract":"Fiber-optic sensors for identifying liquids and determining the concentration of solutions have been studied with the possibility of using various types of single-mode optical fibers produced by industry and widely used in optical cables and telecommunications to create sensors for identifying liquids and determining the concentration of solutions. To identify liquids with different refractive indices and determine the concentration of substances dissolved in water, the peak value of the reflectograms of the optical fiber located at the interface between the optical fiber core and the environment can be used as an information parameter. The value of the information parameter depends on the refractive index of the liquid in which one end of the optical fiber is located. The parameters of fiber-optic sensors for identifying liquids and determining the concentration of solutions were studied by optical reflectometry in different wavelength ranges of optical radiation with a duration of reflectometer probe pulses from 25 to 300 ns. It has been established that the fiber-optic sensor can operate at any wavelength of optical radiation corresponding to the transparency windows of the optical loss spectrum of the optical fiber. The influence of the length of the optical fiber between the recording device and the place where the concentration of a liquid solution is determined using a fiber-optic sensor was studied. The possibility of creating a fiber-optic sensor for determining the concentration of the liquid solutions based on optical fibers has been demonstrated.","PeriodicalId":122672,"journal":{"name":"Doklady BGUIR","volume":"52 8","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Doklady BGUIR","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35596/1729-7648-2023-21-6-14-20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Fiber-optic sensors for identifying liquids and determining the concentration of solutions have been studied with the possibility of using various types of single-mode optical fibers produced by industry and widely used in optical cables and telecommunications to create sensors for identifying liquids and determining the concentration of solutions. To identify liquids with different refractive indices and determine the concentration of substances dissolved in water, the peak value of the reflectograms of the optical fiber located at the interface between the optical fiber core and the environment can be used as an information parameter. The value of the information parameter depends on the refractive index of the liquid in which one end of the optical fiber is located. The parameters of fiber-optic sensors for identifying liquids and determining the concentration of solutions were studied by optical reflectometry in different wavelength ranges of optical radiation with a duration of reflectometer probe pulses from 25 to 300 ns. It has been established that the fiber-optic sensor can operate at any wavelength of optical radiation corresponding to the transparency windows of the optical loss spectrum of the optical fiber. The influence of the length of the optical fiber between the recording device and the place where the concentration of a liquid solution is determined using a fiber-optic sensor was studied. The possibility of creating a fiber-optic sensor for determining the concentration of the liquid solutions based on optical fibers has been demonstrated.
用于识别液体和确定溶液浓度的光纤传感器
对用于识别液体和确定溶液浓度的光纤传感器进行了研究,利用工业生产的、广泛应用于光缆和电信领域的各类单模光纤,制造出用于识别液体和确定溶液浓度的传感器。要识别折射率不同的液体并确定溶解在水中的物质浓度,可以使用光纤芯与环境界面处光纤反射图的峰值作为信息参数。信息参数值取决于光纤一端所在液体的折射率。在不同的光辐射波长范围内,反射仪探头脉冲的持续时间为 25 至 300 毫微秒,通过光反射测量法研究了用于识别液体和确定溶液浓度的光纤传感器的参数。结果表明,光纤传感器可以在与光纤光损耗谱透明窗口相对应的任何光辐射波长下工作。研究了记录装置与使用光纤传感器测定液体溶液浓度的地点之间的光纤长度的影响。研究证明了利用光纤制造用于测定液体溶液浓度的光纤传感器的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信