Evaluation of Sealing Ability of New Composite Filling Material

Emad F. AL-Khalidi عماد فرحان الخالدي, Sabah A. Ismail صباح عبد الوهاب اسماعيل, Mohammed M. Obosi محمد منذر العبوسي
{"title":"Evaluation of Sealing Ability of New Composite Filling Material","authors":"Emad F. AL-Khalidi عماد فرحان الخالدي, Sabah A. Ismail صباح عبد الوهاب اسماعيل, Mohammed M. Obosi محمد منذر العبوسي","doi":"10.25130/tjds.2.1.6","DOIUrl":null,"url":null,"abstract":"This study was conducted to investigate the sealing ability (microleakage) of new composite restorative materials at tooth/composite interface.Thirty non carious, extracted human premolars teeth were mounted in acrylic resin, the teeth were randomly divided into three groups (n=10) according to the type of composite (tetric T-Econom, Evo ceram,IPS Empress). A standardize class V (5×3×2) mm dimensions cavity was prepared on the facial surface of each tooth (each group with corresponding bur type). After the specimens were filled with three types of composite restoration. They stored for one month in 37ºc distilled water, thermo cycled for 500 cycles between (5ºc & 55ºc) and immersed in 2% methylene blue solution for 24h., and then sectioned longitudinally. For both occlusal and gingival margins, dye penetration at the tooth/composite interfaces were scored from 0-3 under stereomicroscope at a magnification x10. Data were analyzed using unpaired T-test, ANOVA, and Duncan’s multiple rang test at 5% significant level.Kruskal-wallis test show that there was a significant difference in microleakage between the three types of composite it represent that there was less microleakage in group filled with IPS Empress while tetric T-Econom show the highest leakage.There was no significant difference in microleakage between IPS Empress and Evo ceram composite filling.AS Conclusions; Within the limitations of this in vitro study the results show that there was less microleakage in the cavities filled with IPS Empress composite and EVO ceram composite as compared with Tetric T-Econom composite.","PeriodicalId":512116,"journal":{"name":"Tikrit Journal for Dental Sciences","volume":"3 5","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tikrit Journal for Dental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25130/tjds.2.1.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This study was conducted to investigate the sealing ability (microleakage) of new composite restorative materials at tooth/composite interface.Thirty non carious, extracted human premolars teeth were mounted in acrylic resin, the teeth were randomly divided into three groups (n=10) according to the type of composite (tetric T-Econom, Evo ceram,IPS Empress). A standardize class V (5×3×2) mm dimensions cavity was prepared on the facial surface of each tooth (each group with corresponding bur type). After the specimens were filled with three types of composite restoration. They stored for one month in 37ºc distilled water, thermo cycled for 500 cycles between (5ºc & 55ºc) and immersed in 2% methylene blue solution for 24h., and then sectioned longitudinally. For both occlusal and gingival margins, dye penetration at the tooth/composite interfaces were scored from 0-3 under stereomicroscope at a magnification x10. Data were analyzed using unpaired T-test, ANOVA, and Duncan’s multiple rang test at 5% significant level.Kruskal-wallis test show that there was a significant difference in microleakage between the three types of composite it represent that there was less microleakage in group filled with IPS Empress while tetric T-Econom show the highest leakage.There was no significant difference in microleakage between IPS Empress and Evo ceram composite filling.AS Conclusions; Within the limitations of this in vitro study the results show that there was less microleakage in the cavities filled with IPS Empress composite and EVO ceram composite as compared with Tetric T-Econom composite.
新型复合填充材料的密封能力评估
这项研究旨在探讨新型复合修复材料在牙齿/复合材料界面的密封能力(微渗漏)。将 30 颗未龋坏、已拔出的人类前臼齿安装在丙烯酸树脂中,根据复合材料类型(tetric T-Econom、Evo ceram、IPS Empress)将牙齿随机分为三组(n=10)。在每颗牙齿的面部制备一个标准的 V 级(5×3×2)mm 尺寸的牙洞(每组都有相应的毛刺类型)。然后用三种类型的复合树脂修复体填充试样。在 37ºc 蒸馏水中保存一个月,在(5ºc 和 55ºc)之间进行 500 次热循环,并在 2% 亚甲蓝溶液中浸泡 24 小时,然后纵向切片。对于咬合边缘和龈缘,在放大倍数为 x10 的体视显微镜下,对牙齿/复合材料界面的染料渗透进行 0-3 级评分。数据采用非配对 T 检验、方差分析和邓肯多重范围检验进行分析,显著性水平为 5%。Kruskal-wallis 检验表明,三种类型的复合材料在微渗漏方面存在显著差异,这表明填充 IPS Empress 的组别微渗漏较少,而填充 tetric T-Econom 的组别渗漏最多。AS 结论;在这项体外研究的局限性范围内,结果显示,与 Tetric T-Econom 复合材料相比,用 IPS Empress 复合材料和 EVO ceram 复合材料填充的牙洞微渗漏较少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信